Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
Excitation system ABB module DSTD150A
Excitation system ABB module DSTD150A
Excitation system ABB module DSTD150
Excitation system ABB module DSTD150
Excitation system ABB module DSTD120
Excitation system ABB module DSTD110A
Excitation system ABB module DSTD110A
Excitation system ABB module DSTD110
Excitation system ABB module DSTD108P
Excitation system ABB module DSTD108 ABB
Excitation system ABB module DSTD108
Excitation system ABB module DSTD108
Excitation system ABB module DSTC456
Excitation system ABB module DSTC456
Excitation system ABB module DSTC454
Excitation system ABB module DSTC190
Excitation system ABB module DSTC176
Excitation system ABB module DSTC175 57310001-KN
Excitation system ABB module DSTC160
Excitation system ABB module DSTC130
Excitation system ABB module DSTC121
Excitation system ABB module DSTC110
Excitation system ABB module DSTA180
Excitation system ABB module DSTA180
Excitation system ABB module DSTA171
Excitation system ABB module DSTA170
Excitation system ABB module DSTA160
Excitation system ABB module DSTA133I
Excitation system ABB module DSTA131
Excitation system ABB module DSTA131
Excitation system ABB module DSTA-121A57120001
Excitation system ABB module DSTA-121A
Excitation system ABB module DSTA121
Excitation system ABB module DSTA002
Excitation system ABB module DSSS170
Excitation system ABB module DSSR122M
Excitation system ABB module DSSR122 ABB控制器
Excitation system ABB module DSSR122 4899001-NK
Excitation system ABB module DSSR122 48990001-NK
Excitation system ABB module DSSR122 48990001-LH
Excitation system ABB module DSSR122
Excitation system ABB module DSSR122
Excitation system ABB module DSSR121
Excitation system ABB module DSSR120
Excitation system ABB module DSSR116
Excitation system ABB module DSSR115
Excitation system ABB module DSSR110
Excitation system ABB module DSSC-01C
Excitation system ABB module DSSB170
Excitation system ABB module DSSB146
Excitation system ABB module DSSB145
Excitation system ABB module DSSB140 48980001-P
Excitation system ABB module DSSB140
Excitation system ABB module DSSB140
Excitation system ABB module DSSB120
Excitation system ABB module DSSB110
Excitation system ABB module DSSB-01C 3AFE68300746
Excitation system ABB module DSSB-01C
Excitation system ABB module DSSB-01C
Excitation system ABB module DSSB-01C
Excitation system ABB module DSSA165
Excitation system ABB module DSSA165
Excitation system ABB module DSSA165
Excitation system ABB module DSRF197 3BSE019297R1
Excitation system ABB module DSRF182K13