Description
CR215GH12+CR215GFE GE Fanuc Controller Carrie
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
HD-522 SHINBORY DENSHI Heater Control Switch Panel
321131-A01 337672-A01 Allen-Bradley Interface Board
394877-A02 4002604070 Allen-Bradley PC board
314066-A02 Allen-Bradley PC POWER SUPPLY BOARD
2711-K10C1 Allen-Bradley PanelView 1000 Standard Operator Terminal
1336-SN-SP10A 74101-363-51 Allen-Bradley component of the Bulletin 1336 drives
GPD506V-B004 MAGNETEK AC DRIVE
1771-OJ/A Allen-Bradley pulse output expander module
GVC704AE01 5SXE05-0152 3BHB003230R0101 3BHB003023P201 ABB
GDC801B101 3BHE051592R0101 ABB
1794-IB16 Allen-Bradley Flex IO DC Input Module
2711-K5A8 Allen-Bradley Panelview 550 Standard Operator Terminal
IC660BBA100 GE analog I/O Block
DSDX453 5716075-AN ABB Remote In / Out Expansion Unit
135462-01 Bently Nevada PLC module
132419-01 Bently Nevada PLC module
132417-01 Bently Nevada PLC module
2711P-T6C5A Allen-Bradley Panelview Plus 600 series operator interface terminal
1771-OFE2 Allen-Bradley analog output module
1771-IR Allen-Bradley PLC5 Resistance Temperature Detector (RTD) input module
330100-90-00 Bently Nevada Proximitor Sensor
1771-IFMS Allen-Bradley intrinsically safe fast millivolt input module
1771-OBDS Allen-Bradley digital output module
1771-IBN Allen-Bradley PLC5 Discrete Input module
1771-CFM Allen-Bradley configurable type of flow meter module
1771-ACN Allen-Bradley ControlNet adapter module
1402-LS51 Allen-Bradley Line Synchronization Module
WR-D4004 MD-D4014B RELIANCE
A2H254-16-RH A2H254-16 Enterasys Networks Network Switch
TK457V050 3BSE004394R1 ABB Cable assembly
SCXI-1000 NI Low-Noise, 4-Slot, AC Chassis
SCXI-1304 NI –3 dB Cutoff Frequency, 60 V, AC/DC Coupling Terminal Block
PCIH38F300A1 UPWRA-KW3M2UPWR Positronic Rectangular power connector
DSCS150 57520001-FY ABB GCOM Communication Unit
TC-CCR014 97321174-A01 HONEYWELL Redundant Net Interface
SCXI-1600 NI 16-Bit, 200 kS/s Sampling Rate, Data Acquisition Module
P0926AH-B FOXBORO Power Supply
SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module
P0973CN FOXBORO FIELDBUS COMMS BASE MODULE
IC697BEM731Z GE Bus Controller Module
ESA-700 EPSD-0375-1108 ALSTOM Limelight Flame Signal Analyzer
9200-06-01-10-00 Bently Nevada 9200 watt vibration probe
MVI56-MDA4 PROSOFT MDA Scientific CM4 Platform Master Module
MVI56-LTQ PROSOFT Limitorque Valve Network Interface Module
PQV80020041 VALMET