Sale!

CI840A DCS excitation system ABB

Original price was: $1,888.00.Current price is: $1,688.00.

Model:CI840A

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

CI840A DCS excitation system ABB
CI840A DCS excitation system ABB
CI840A DCS excitation system ABB Product details:
CI840A is an interface communication module from ABB, with product model CI840A. This module is commonly used in industrial automation systems,
especially in the field of process control. Here are some possible application and product operation areas:
Industrial automation: ThCI840A communication module may be used to communicate with other automation equipment, control systems,
or sensors to achieve automation and integration of industrial production lines.
Process control: This module may be used to monitor and control various processes, such as chemical plants, power plants, pharmaceutical plants,
etc. Through communication with other devices, it can achieve data exchange and control instruction transmission.
PLC (Programmable Logic Controller) systemCI840A may be integrated into the PLC system for communication with other PLC modules or
external devices, achieving centralized management of the entire control system.
Data collection and monitoring: In the data collection systemCI840A can be used to obtain data from various sensors and devices,
and transmit this data to the monitoring system for real-time monitoring and analysis.
Remote monitoring and operation: Through collaborative work with other communication modulesCI840A may support remote monitoring and operation,

allowing operators to monitor and control the production process from different locations.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

A413139   Network I/O processor
DSTA131 Drive data manager  controlling drives
PXIE-5105  High-density PXI oscilloscope
D201471  Digital input/output module
A413188  Multiprocessor system
IC200ALG320 Analog output module
D201376 Analog input module analog signals
XVR19 6U-VME-SBC  Single board computer
D201190 Flow control valve high performance
CTB810  HN800 Communication terminal board
FPN1903A   Switching power supply
CRIO-9073 controller   embedded system
D3000 Dual protection mechanism
SHC68-68-EPM  With redundant power input
BMXDDI3202K   Input module  into digital
BMXCPS2010  isolated power module
BMXDDO6402K  Discrete quantity output module
1794-IF4IXT  Motor control equipment
150-C85NBD   Soft starter  redundant input
HPC800底座MB810   Data collection and alarm management
A413139 Computer controller
VMIVME 3215-000   cpu module
PC834-001-T  laboratory instruments
D201471 Digital input and output module
F860-CA High quality terminal board
MDB-8E Micro electronic balance
AI02J  High precision current transmitter
FCM2F2 P0914YZ Bus extender
CRIO-9073 embedded controller
ZMI-4104 displacement measurement electronic
S30361-NA DANAHER servo controller
PW702 Power module  overvoltag
REF610C11HCNN01(含底座)  contactor
MVME55006E-0161R  High performance embedded computer
87199-01 digital signal processor
MTL4842 Surge Protective Device
85UVF1A-1QD  Solid state flame detector
EMERSON A6370D Digital expansion module
IC200PBI001  GE  Network Interface Unit
CRIO-9073  NI  CompactRIO Controller
85UVF1A-1QD Integrated Flame Scanner with Internal Relay
S30361-NA DANAHER  KOLLMORGEN  Servo driver
ZMI-4104  Displacement measurement Interferometers
PW702  YOKOGAWA  Dc power module
“ABB AI02J  A current transmitter”
Foxboro RH926GQ Distributed I/O module
FOXBORO FCM2F2 P0914YZ  Bus expander
A-B 1756-IF4FXOF2F  Analog input channel
VE4006P2 Programmable controller
136703-01  Communication module
ABB DSQC652  Standard IO signal board
EMERSON IC200PBI001 Network interface unit

Reviews

There are no reviews yet.

Be the first to review “CI840A DCS excitation system ABB”

Your email address will not be published. Required fields are marked *