Description
4006L4102AAG003 General Electric
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
Implementation of communication between ABC industrial robot and PLC based on DeviceNet fieldbus technology
introduction
In modern production systems, industrial robots and PLCs need to communicate and collaborate to complete production tasks. That is, the
industrial robots output signals to the PLC, allowing the PLC to control related equipment to drive the robot”s front-end tools. This article
mainly analyzes the communication problems between ABB industrial robots and PLC based on DeviceNet fieldbus technology.
DeviceNet is a common network communication method in the field of automation. ABB industrial robots establish a network to communicate with
Siemens PLC based on the DeviceNet network.
1Configure DSQC652
There are mainly 5 types of standard I/0 boards commonly used in ABB industrial robots [2]. Except for the different addresses assigned to
them during setup, their configuration methods are basically the same. This article mainly analyzes the ABB standard I/0 board DS0C652, which
mainly builds communication modules based on the DeviceNet network. The DS0C652 board has a distributed I/O module with 16 digital input and 16
digital output interfaces. The board is installed in the ABB industrial robot control cabinet. First, define the specific operation steps of the DS0C652 board,
enter the teach pendant control panel, then enter the configuration menu (Figure 1), select the DeviceNetDevice menu, and add a template to enter Figure 2.
ABB standard I/0 board is hung on the DeviceNet
network, so the address of the module in the network must be set. The jumpers 6 to 12 of terminal x5 are used to determine the address of the module.
The available address range is 10 to 63. Modify the parameters in the template parameters to complete the DS0C652 board settings. Click the drop-down
menu to select the “Use value from template” row, select
“DS0C65224VDCI/0Device”, and then the parameters that need to be set include the address of the I/0 board in the bus.
Figure 1 Configuring DSQC652
2Configure signals and parameters
After completing the DS0C652 board setting, the I/0 signal setting will be performed. Setting the I/0 signal is the basis for establishing communication with
the PLC. The PLC communicates and transmits data with the ABB industrial robot through the I/0 signal and the DS0C652 board. As shown in Figure 3, in the
signal configuration interface, there are many default I/0 points after the system is established. Modification is not allowed. Click “Add” to add signals. When setting
input and output signals, their address range is 0~15. First, enter the signal menu in the configuration options to set the input and output types, and modify the corresponding parameters.
After completing the settings, the computer prompts that you need to restart the settings. If there are multiple signals that need to be defined and the waiting time
is long after restarting multiple times, you can click “Cancel” and wait for all signals to be defined before clicking the “Yes” button to restart. After the signal settings are
completed, click to select “Input and Output” in the ABB menu to check whether all signals have been set.
Figure 2 Configure DSQC652 parameters
Figure 3 Signal parameter settings
During the signal establishment process, attention should be paid to the DSoC652 port and PLC port addresses used, and the corresponding address table should be
established, as shown in Table 1. The robot interacts with the PLC through I/O signals. During the setting process, there must be no errors in the port and address number
of the PLC connected to the DSoC652. If the address is set incorrectly, the communication between the robot and the PLC will not work properly.
The entire robot teaching pendant setting process is shown in Figure 4.
CC-PAOH01 51405039-175 HONEYWELL HART Analog Output Module
CC-PAIN01 51410069-175 HONEYWELL Analog Input Module
CC-PAIX01 51405038-275 HONEYWELL Experion High Level Analog Input Module
CC-PAIH51 51410069-275 HONEYWELL Analog Input Module
CC-PAIH01 51405038-175 HONEYWELL Analog Input with HART
CC-PAIH02 51405038-375 HONEYWELL C300 Hart Analog Input
6DD1683-0BC5 Siemens Power Supply
1746-NI16I Allen-Bradley SLC 500 Analog I/O Module
1C31125G02 Westinghouse Digital Output Module
1X00781H01L EMERSON POWER SUPPLY
1C31132G01 Westinghouse Analog Output
P0904HN LZS 1500-3FOX FOXBORO Power module
CR-GEN0-M6400R3 DALSA High speed CCD line scanning camera
DSQC661 3HAC026253-001 ABB Power Supply
DTDX991A 61430001-UW ABB Analog Module
DSQC609 3HAC14178-1 PBSE5117 ABB Power Supply
1747-BA Allen-Bradley SLC 500 Lithium Battery
5SHX06F6004 3BHB003387R0101 ABB IGCT module
DTCC901B DCC2390A ABB Excitation system controller
651T-0600 Acromag Single Channel Process Current Transmitter/Isolator
12KM02E-V0002 3EGM030300R0002 ABB Multi-axis control unit
T8448 ICS Triplex Trusted TMR 24Vdc Zone Interface Module
T8161B ICS TRIPLEX Trusted TMR Processor
P026MX FOXBORO Fbm Modules
P0916VL FOXBORO Termination Cable
P0916VB FOXBORO Termination Cable
FBM240 P0917GZ FOXBORO DCS CARD MODULE FBM
FBM208 P0914TB FOXBORO Redundant 0-20 Module w/Readback
FBM206 P0916CQ FOXBORO Terminal Assembly
FBM204 P0914SY FOXBORO Channel Isolated
FBM202 P0926EQ FOXBORO Channel Isolated 8 Input
FBM201e P0924TR FOXBORO Analog Input Interface Modules
FBM201D P0922YK FOXBORO Analog Input Interface Modules
57552-4 RELIANCE Universal Drive Controller Module
57405 Reliance I/O Analog DCS Module
57401 RELIANCE Digital I/O Drive
57C430 RELIANCE Processor Module 6010
TRICONEX CM2201 TRICONEX Communication Module
57C404C RELIANCE COMMUNICATION NETWORK MODULE
VME162PA-344SE Motorola Embedded Controller
57652 0-57652-D RELIANCE Universal Drive Controller Module
57C443 RELIANCE Remote I/O Scanner Module
57C435 RELIANCE 7010 Series Processor Module
57C409 RELIANCE 2 Channel Analog Input Module
57C411 RELIANCE Resolver Input Module
57C410A RELIANCE Analog Output Module
57C404C RELIANCE COMMUNICATION NETWORK MODULE
HE693ADC410A GE Analog Input Modules
FBM203 P0914SV FOXBORO Channel Isolated 8 Input RTD
IC754CSL12CTD GE Operator Interface Terminal
IC754VSI12VTD GE 12-inch color TFT touch fast panel display
00-108-947 KUKA KRC2 MR-E MOTOR CABLE
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.