Description
1. introduction
abb dcs is a distributed control system designed and developed by Swiss Asea Brown Boveri Company (abbreviated as abb company). It has a wide range of applications and can be used in discrete manufacturing industries , such as machine tools, automobiles, aircraft manufacturing and other industries, as well as in large and medium-sized enterprises. Small-scale continuous production process industries, such as petroleum, chemical industry, thermal power units, steelmaking, building materials and other industries. abb dcs system adopts international standards from hardware design to software design and communication. The software programming language ampl (asea mas ter pi ece language) of abb dcs is a programming mode of the control system. This article introduces the architecture of abb dcs and its fieldbus network.
2 abb dcs distributed industrial control computer system architecture
abb dcs distributed control system uses advanced microprocessors (33mhz motorola 68020 and 33mhz intel 80386, 80486 chips), crt graphic display technology, high-speed safety communication technology and modern control theory to form an on-site control station (mp200, ac410 , ac450 series and local and remote i/o series), operator station (as500 series), engineer station (master ai d series), information management system station (advant station series ), computer and network interface station (master gate series), computer network (master bus series) and other computer communication equipment, it is a large-scale intelligent network with dispersed physical locations, dispersed system functions, dispersed control functions, and centralized operation display management for process control and process decision-making management. The communication network structure of abb dcs is divided into three layers:
3 Information Management Network Layer
It can be connected to 9 control networks. The network is composed of type mb300 bus, and the bus transmission rate reaches 10mbps.
4 Control network layer
The control network layer consists of 9 buses of type mb300. A control network may include 99 stations (including stations in local control networks). Each mp200/1 or ac450 station in the control network can be connected to a local control network. A local control network can include 9 buses of type mb300. mb300 is a high-performance, serial, synchronous, half-duplex high-speed bus with large data volume. It adopts ieee 802.2 logical link control (llc) protocol and ieee 802.3 carrier frame listening multiple access with conflict detection (csma/cd) media access control (mac) protocol. It is an ethernet type LAN and the bus can carry loads . 45 nodes. When no repeater is used, the maximum communication node distance is 500m; when using 3 coaxial segments, 4 repeaters and 2 point-to-point links, the maximum communication node distance is 2500m, and the bus transmission rate is 10mbps.
mb300 realizes the connection to the host computer and communication with PLC systems such as MP200 through each node . It generally follows the 543 rule, that is, it is composed of 5 sections and 4 repeaters (repeater) connections, 3 of which can be connected to equipment. It must be noted that only the marked prescription of the cable can be connected through the transceiver ( tranceiver ) Equipment, different equipment connections use different connection cables, such as tk526 cable to the pu510 operating station, and tk576 cable to the control station. The tranceiver can only be installed at the 2.5-meter mark on the main cable section. The spacing between the tranceivers on the coaxial cable section between the two line joints should be an integer multiple of 25 meters. The connection method is as shown in the figure.
t1 and t2 are terminal resistors . As long as one end is grounded, the terminal resistance is 50 ohms. The mb300 bus is a coaxial cable. It is divided into thick cable, thin cable and optical cable. Their functions are different. When laying the coaxial cable, you need to pay attention to it. Isolation from other signal cables, such as 30cm away from signal cables, 50cm away from 380v low-voltage cables, and 5m away from high-voltage cables. The mb300 bus uses the cs513 interface card. The three dial switches s1, s2, and s3 are used to set the network number, node number, and protocol number respectively. The low four bits of s1 are used to set the master/slave station selection. The high four bits are used to set the protocol number, s2 is used to set the node number, and s3 is used to set the network number. When it is necessary to modify or find out the cause of the fault through fault information, you can enter the engineering station to modify the data or know the fault location of the mb300 bus through the fault code. Understand the communication factors that affect mb300 and analyze these factors one by one.
Excitation system ABB module 3HNA024871-001
Excitation system ABB module 3HNA024203-001
Excitation system ABB module 3HNA023282-001
Excitation system ABB module 3HNA023200-001
Excitation system ABB module 3HNA018573-001
Excitation system ABB module 3HNA018564-001
Excitation system ABB module 3HNA016493-001
Excitation system ABB module 3HNA015771-001
Excitation system ABB module 3HNA015495-001/01
Excitation system ABB module 3HNA015162-001
Excitation system ABB module 3HNA015149-001
Excitation system ABB module 3HNA015149-001
Excitation system ABB module 3HNA013638-001/03
Excitation system ABB module 3HNA012283-001
Excitation system ABB module 3HNA011999-001
Excitation system ABB module 3HNA011788-001/01
Excitation system ABB module 3HNA011334-001
Excitation system ABB module 3HNA011334-001
Excitation system ABB module 3HNA011333-001
Excitation system ABB module 3HNA010906-001
Excitation system ABB module 3HNA010598-001/03
Excitation system ABB module 3HNA010598-001 DSQC378B
Excitation system ABB module 3HNA009724-001
Excitation system ABB module 3HNA009609-001
Excitation system ABB module 3HNA007885-002
Excitation system ABB module 3HNA007719-001
Excitation system ABB module 3HNA007073-001/03
Excitation system ABB module 3HNA007022-001
Excitation system ABB module 3HNA007022-001
Excitation system ABB module 3HNA007022
Excitation system ABB module 3HNA006570-001
Excitation system ABB module 3HNA006492-001/04
Excitation system ABB module 3HNA006330-001
Excitation system ABB module 3HNA006262-001
Excitation system ABB module 3HNA006149-001
Excitation system ABB module 3HNA006149-001
Excitation system ABB module 3HNA006146-001
Excitation system ABB module 3HNA006145-001
Excitation system ABB module 3HNA006144-001/03
Excitation system ABB module 3HNA006144-001/03
Excitation system ABB module 3HNA006144-001
Excitation system ABB module 3HNA004958-001
Excitation system ABB module 3HNA002064-001
Excitation system ABB module 3HNA001625-001
Excitation system ABB module 3HNA001625-001
Excitation system ABB module 3HNA000512-001
Excitation system ABB module 3HB012961R0001
Excitation system ABB module 3HAC9710-1
Excitation system ABB module 3HAC8627-1
Excitation system ABB module 3HAC8593-1
Excitation system ABB module 3HAC8500-6
Excitation system ABB module 3HAC8409-1
Excitation system ABB module 3HAC8311-2
Excitation system ABB module 3HAC8280-1
Excitation system ABB module 3HAC8278-1/04
Excitation system ABB module 3HAC8185-4
Excitation system ABB module 3HAC8085-2
Excitation system ABB module 3HAC7998-8
Excitation system ABB module 3HAC7998-7
Excitation system ABB module 3HAC7970-1
Excitation system ABB module 3HAC7681-1
Excitation system ABB module 3HAC7681-1
Excitation system ABB module 3HAC7664-1
Excitation system ABB module 3HAC7457-3
Excitation system ABB module 3HAC7344-1
Excitation system ABB module 3HAC7344-1
Excitation system ABB module 3HAC7310-1
Excitation system ABB module 3HAC7149-1
Excitation system ABB module 3HAC6877-1
Excitation system ABB module 3HAC6792-1
Excitation system ABB module 3HAC6762-1
Excitation system ABB module 3HAC6696-1
Excitation system ABB module 3HAC6449-1
Reviews