Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
200-595-002-011 VIBRO VM600 IOC4T INPUT
200-566-000-012 200-566-101-012 VIBRO
200-510-017-017 200-510-111-013 MPC4 Vibro Meter VM600 MPC4 Machinery Protection
10QT01 GJR2209300R0001 10QT01A-ER0001 BBC DCS Module
5X00489G01 Westinghouse Power Distribution Module
1C31206G01 Westinghouse MODULE BASE ASSEMBLY
1C31205G01 Westinghouse Remote Node Controller Base
UNC4672A V1 HIEE205012R1 ABB Basis unit
UFC921A101 3BHE024855R0101 ABB INT-2 Board Varnished
SB822 3BSE018172R1 ABB Rechargeable Battery Unit
SA811F 3BDH000013R1 ABB Power Supply Module
PPC905AE101 3BHE014070R0101 ABB control board
PE1315A ABB Opto isolated pulse amplifier
8521-TC-SA GE Analog expansion module
8121-DI-DC GE 16-channel Digital Input
1746SC-INO4I Allen-Bradley Analog Output Module
8115-DO-DC GE 8-channel Digital Output
5SHY3545L0020 3BHE014105R0001 ABB IGCT Module
6ES132-1BH00-0XB0 Siemens ET 200L Digital Input Module
PR9376010-011 9200-00097 EPRO Proximity Sensor
MMI301 GE PROCESSOR MODULE
IMHSS03 ABB Infi 90 Hydraulic Servo Slave Module
086318-002 086318-501 ABB MEMORY DAUGHTERBOARD
D138-002-002 MOOG solenoid valve
MS90376-12Y GE Dc controller governor
RLX2-IHNF-A PROSOFT interrupter
AXLINK100 892.202988 AUTOMATION network connector
07KR31 FPR36000227R1202-S ABB Procontic Central Processing Unit
MPRC086444-005 ABB Card board
JGSM-06 YOKOGAWA Position Controller
PPD539A102 ABB Static excitation system controller
WESCOM D200 VME WESCOM D200 VME D20 M++ GE frame
WES5302-150 GE Thermoelectric card
WES5302 WES5302-111 GE Thermoelectric card
WES13-3 GE Safety module
PP49283-8 T8846 ICS TRIPLEX PI terminal board
TP867 ABB Baseplate
D20 EME 10BASE-T GE Processor module
5600633 T8800 ICS TRIPLEX Trusted 40 Channel 24V Dc Digital Input FTA
3BSE040662R1 AI830A ABB Analog input RTD 8 ch
3BSE008508R1 DI810 ABB Digital Input 24V 16 ch
CI627 ABB AF100 Communication Interface
PM633 ABB Processor Module
SC610 ABB Analog Input 16Ch 12 bit
DO620 ABB Digital Output 32ch 60VDC
AI625 ABB Analog Input 16ch 12 Bit 4-20 mA
AI610 ABB Analog Input 16Ch 12 bit
CSH01.1C-SE-EN2-NNN-NNN-NN-S-XP-FW Rexroth SERVO DRIVE CONTROL UNIT INDRADRIVE
8724-CA-PS GE IS module power supply carrier
Reviews