Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
IS200AEBMG1A Input module
IS200AEBIH1ADC GE MARK VI board
IS200AEADH1A Input/output module
IS200AEAAH1C printed circuit board
IS200AEAAH1AAA Mark VI Printed circuit board
IS200AEAAH1A printed circuit board
IS200ADIIH1AAA ISBUS interface board
IS200ADIIH1A Input/output module
IS200ACLEH1BCB Serial port measurement module
IS200ACLAH1A Control layer module
IS200ACLEH1A Application control layer module
IS400ERSEG1A Automatic controller
IS215ACLEH2A adapter module
IS215ACLEH1B Control layer module
IS215ACLEH1C Dual-port module
IS215ACLEH1A Ethernet port
IS215ACLAH1A Control layer module
IS210MVRCH1A excitation power distributor
IS210MVRCH1A gas turbine system module
IS210ERGTH1A Detector terminal board
IS200MVRCH1A Mark V and VI system modules
IS200HSLAH5A EX2100e series high-speed interface
IS200HSLAH4A Serial link interface
IS200HSLAH1A host application module
IS200HSLAH1ADE EX2100e series host application board
MVI69E-MBTCP PROSOFT TCP/IP enhanced communication module
IS200EXTBG3A Redundant control module
IS200EXTBG4A exciter terminal board
IS200EXTBG1A Input/output module
IS200EXTBG2A excitation terminal board
IS200EXMDG1B Exciter MD feedback board
IS200EXMDG1A MD feedback board
IS200EXHSG4A static exciter terminal board
IS200EXHSG3A relay driver
IS200EXHSG2A excitation high speed relay
IS200EXHSG1A relay driver board
IS200EXCSG1A Sensor board
IS200EXAMG1B exciter attenuation module
IS200EXAMG1A Excitation attenuation module
IS200ESELH2A drive module
IS200ESYSH3A programmable control module
IS200ESBPG1A EX2100 series backplane connectors
IS200ESELH1A drive module
IS200ERSNG1A Conversion control module
IS200ERSCG2A Excitation regulator static transfer board GE
IS200ERRRH1A redundant relay
IS200ERSCG1A Static converter
IS200ERRBG1A Redundant backplane
IS200EROCH2A connector
IS200EROCH1A Excitation Regulator TAB
IS200ERIOH1A I/O module
IS200ERGTH1A Ground detection board
IS200ERDDH1A dynamic discharge panel
IS200ERBPG1A Midplane module
IS200EPSMG2A Power module
IS200EPSMG1A exciter power module
IS200EPDMG1B Power distribution module of the exciter
IS200EPDMG1A Power distribution module
IS200EPCTG1A exciter PT/CT plate
IS200EMIOH1A I/O module
IS200EMCSG1A Conduction sensor card