Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
ABB KU C755 AE108 GATEUNITPWRSUPPLY KUC755AE108
UFC911B106 CVMI2B BOARD UF C911 B106
ABB UFC911B110 printed boards UF C911 B110
UFC911B108 Printed circuit board UF C911 B108
UFC921A101 Board Varnished UF C921 A101
UF C784 AE101 ABB UFC784AE101 electronic module
UF C911 B101 ASEA BROWN BOVERI UFC911B101
UF C760 BE43 ABB UFC760BE43 MAIN CIRC. INTER
UF C784 AE ABB UFC784AE Controller module
UF C765 AE02 ABB UFC765AE02 Frequency converter module
UF C760 BE45 ABB UFC760BE45 PHASE MODULATOR
UF C766 AE01 ABB UFC766AE01 MAIN CIRC. INTER.
UF C760 BE42 ABB UFC760BE42 MAIN CIRC. INTER.
UF C766 AE01 ABB UFC766AE01 VOLTAGE/CURRENT M ADCVI
UF C760 BE41 ABB UFC760BE41 MAIN CIRCUIT INTE
UF C721 AE ABB UFC721AE VOLTAGE/CURRENT M ADCVI
UF C911 B110 ABB UFC911B110 CVMI2B BOARD
UF C762 AE101 ABB UFC762AE101 Medium and high voltage module
UF C921 A101 ABB UFC921A101 INT-2 Board Varnished
UF C760 BE141 ABB UFC760BE141 INTERFACE BOARD
UF C760 BE141 ABB UFC760BE141 INTERFACE BOARD
UF C765 AE102 ABB UFC765AE102 EAF-BOARD COATED
UF C760 BE143 ABB UFC760BE143 INTERFACE BOARD
UF C718 AE101 ABB UFC718AE101 MAIN CIRCUIT INTE INT
UF C718 AE101 ABB UFC718AE101 MAIN CIRCUIT INTE INT
UF C719 AE ABB UFC719AE I/O CONTROLBOARDS IOEC
UF C762 AE ABB UFC762AE CVMI-BOARD
UF C718 AE01 ABB UFC718AE01 MAIN CIRCUIT INTE INT
UF C760 BE145 ABB UFC760BE145 PHASE MODULATOR
UF C718AE ABB UFC718AE INT-BOARD JUMPER
UF C721 BE101 ABB UFC721BE101 ADCVI-Board Coat
UF C719 AE ABB UFC719AE I/O CONTROLBOARDS IOEC
UF C921 A103 ABB UFC921A103 BOARD MEGASTAR
UF C762 AE ABB UFC762AE 3BHE006412R0001 CVMI-BOARD
UF C718 AE01 ABB UFC718AE01 MAIN CIRCUIT INTE INT
UF C911 B104 ABB UFC911B104 CVMI2B
UFC784AE101 ABB UF C784 AE101 FSCD-BOARD,COATED
UF C760 BE42 ABB UFC760BE42 MAIN CIRC. INTER
UFC912A101 ABB UF C912 A101 Controller module
UFC921A102 ABB UF C921 A102 BOARD REDUCED
UF C911 B106 ABB UFC911B106 Medium and high voltage module
MVME147-012A 16MB Single Board Computer
CIMR-HB4A0039 An Chuan Inverter
P0916NG terminal component FBM242
IC755CSS10CDA 10.4-inch standard TFT LCD screen
IS200ISBEH2A expansion board
ADV559 digital output module
PCI-7811R digital reconfigurable I/O device
ADV159 digital input module
VMIVME-5576 reflective memory board
CC-PWRR01 Redundant Power Module
HCS02.1E-W0012-A-03-NNNN servo drive power supply part
MSK040C-0600-NN-S1-UG0-NNNN actuating motor
5517D-C19 laser head
VMIVME-2540 intelligent counter controller
PCI-6503 digital input and output device
1747-DPS2 port splitter module
A8516-040 Turbine Mechanical Hydraulic Governor
1761-L32BWB master relay
3500/42-01-00 (176449-02+128229-01) Proximitor Earthquake Monitor
5X00109G02 high performance analog input module
1783-IMS28GNAC switch
3500/94M-03-00-00 VGA display
NU8976A99 HIER466665R0099 ABB Controller module
1783-BMS10CGP 10-port managed Ethernet switch