Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
Excitation system ABB module PfeifferTPR280
Excitation system ABB module PFEA113-65 3BSE050092R65
Excitation system ABB module PFEA113-65 3BSE050092R65
Excitation system ABB module PFEA113-65 3BSE028144R0065
Excitation system ABB module PFEA113-65
Excitation system ABB module PFEA113-65
Excitation system ABB module PFEA113-20 3BSE050092R20
Excitation system ABB module PFEA113-20 3BSE028144R0020
Excitation system ABB module PFEA113-20
Excitation system ABB module PFEA113
Excitation system ABB module PFEA112-65 3BSE050091R65
Excitation system ABB module PFEA112-65 3BSE030369R0065
Excitation system ABB module PFEA112-65
Excitation system ABB module PFEA112-20 3BSE050091R20
Excitation system ABB module PFEA112-20
Excitation system ABB module PFEA112-20
Excitation system ABB module PFEA112
Excitation system ABB module PFEA111-65 3BSE050091R65
Excitation system ABB module PFEA111-65 3BSE050090R65
Excitation system ABB module PFEA111-65 3BSE050090R65
Excitation system ABB module PFEA111-65 3BSE028140R0065
Excitation system ABB module PFEA111-65
Excitation system ABB module PFEA111-65
Excitation system ABB module PFEA111-65
Excitation system ABB module PFEA111-20 3BSE050090R20
Excitation system ABB module PFEA111-20 3BSE050090R20
Excitation system ABB module PFEA111-20 3BSE028140R0020
Excitation system ABB module PFEA111-20 3BSE028140R0020
Excitation system ABB module PFEA111-20
Excitation system ABB module PFEA111-20
Excitation system ABB module PFEA111
Excitation system ABB module PFEA101
Excitation system ABB module PFCL301E
Excitation system ABB module PFCL201CE-20KN
Excitation system ABB module PFCL201CE
Excitation system ABB module PFCL201C/CD
Excitation system ABB module PFCL201C 10KN
Excitation system ABB module PFCL201C 5KN 3BSE027070R5
Excitation system ABB module PFCL201C 20KN
Excitation system ABB module PFCL201C 10KN
Excitation system ABB module PFCL201C
Excitation system ABB module PFCL201C
Excitation system ABB module PFCL 201CE-50
Excitation system ABB module PFCA401SF 3BSE024387R4
Excitation system ABB module PFBL141B-75KN
Excitation system ABB module PFBL141B/C
Excitation system ABB module PFBK165
Excitation system ABB module PE1315A
Excitation system ABB module PDX11-FBP.500
Excitation system ABB module PDX11-FBP.300
Excitation system ABB module PDX11-FBP.100
Excitation system ABB module PDV12-FBP.0
Excitation system ABB module PDV11-FBP.0
Excitation system ABB module PDR11-FBP.150
Excitation system ABB module PDP22-FBP.500
Excitation system ABB module PDP22-FBP.200
Excitation system ABB module PDP22-FBP.100
Excitation system ABB module PDP22-FBP.050
Excitation system ABB module PDP22-FBP.025
Excitation system ABB module PDP22-FBP.025
Excitation system ABB module PDM11-FBP.0
Excitation system ABB module PDM11-FBP.0
Excitation system ABB module PDF11-FBP.0
Excitation system ABB module PDF11-FBP.0
Excitation system ABB module PDD500A101
Excitation system ABB module PDD200A101
Excitation system ABB module PDB-2 3HNA023093-001
Excitation system ABB module PDB-02 3HNA023093-001
Excitation system ABB module PDB-02 3HNA023093-001
Excitation system ABB module PDB-02 3HNA023093-001
Excitation system ABB module PDB-02 3HNA010534-001/04
Excitation system ABB module PDB-01 3HNA006147-001
Excitation system ABB module PDAA401 3BSE017234R1
Excitation system ABB module PDAA401 3BSE017234R1
Excitation system ABB module PDA12-FBP.050
Excitation system ABB module PDA12-FBP.050
Excitation system ABB module PDA11-FBP.050
Excitation system ABB module PDA11-FBP.050
Reviews
There are no reviews yet.