Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In a DC brush motor, the stator is a permanent magnet and the rotor is a wound coil; the magnetism has two poles, which repel each other and attract each other.
Therefore, passing direct current through the rotor coil will allow the rotor to rotate until it reaches the position where the torque is the smallest with the stator. At this
time, due to the commutation of the brushes, the position where the torque was originally the smallest becomes the position where the torque is the largest. Finally,
over and over again, the rotor continues to rotate. .
Brushless DC does not have brushes; at the same time, in brushless DC motors, the stator is a permanent magnet and the rotor is a winding structure.
In brushless DC motors, the stator is a winding and the rotor is a permanent magnet. If the winding is still on the rotor, you have to rely on physical contact to energize
the winding, which does not solve the problem of brush aging. In the brushless DC motor, the winding exists in the stator and has three phase wires; when working, the
input and output currents are successively supplied to the three phase wires to achieve the purpose of commutation. In brushless DC, the electromagnetic force generated by the
rotor and stator is the same as that of brushed DC.
For brushless DC motors, it is not necessarily whether the stator is inside or outside. A motor with a rotor outside and a stator inside is generally
called an external rotor motor. The hub motor is a very special external rotor motor.
Brushless DC motor, why is it classified as AC motor?
This is because when we supply power to the controller of brushless DC and permanent magnet synchronous motors, we supply DC
power, so it is called brushless DC; however, after the DC power is inverted through the motor controller, it communicates with the motor. For the three connected phase lines,
the power supply type changes to AC. Only the changing phase voltage of AC can cause the current on the three phase lines of the motor to continuously reverse direction,
so the motor is classified as an AC motor.
3. Similarities and differences between brushless DC and permanent magnet synchronization
Brushless Direct Current Motor, English BLDC, English full name Brushless Direct Current Motor
Permanent Magnet Synchronous Motor, English PMSM, English full name: Permanent Magnet Synchronous Motor
DSTS106 3BSE007287R1 Trigger pulse Generator cassette backup regulator
DI650 3BHT300025R1 Digital input 32 channels
DSTS105 3BSE007286R1 is used to simulate a backup regulator
3500/92-02-01-00 Communication gateway
TC515V2 3BSE013284R1 AF100 Twisted pair repeater
DSAI155A 3BSE014162R1 thermocouple module
TC512V1 3BSE018059R1 RS485 Twisted pair modem
DSAO130A 3BSE018294R1 Analog output board 16 channels
DSTA155P 3BSE018323R1 Connect unit 14 thermocouple
DSTA002B 3BSE018317R1 Analog input board connection unit
DSTA135 3BSE018315R1 input board
DSTD190V1 3BSE018314R1 Connects to unit 32 Ch
DSTA001B 3BSE018316R1 Analog long connection unit
DSTA001B 3BSE018316R1 Analog long connection unit
DSTA181 3BSE018312R1 connection unit for simulation
DSTA156B 3BSE018310R1 Connect unit 32 Ch
CI522AK04 3BSE018451R1 Communication module
CI522AK02 3BSE018449R1 Communication bus module
CI522AK01 3BSE018448R1 Field Bus interface module
CI522AK03 3BSE018450R1 Communication module
DSTD108P 3BSE018333R1 Connects to Unit 8 Ch
DSTD108LP 3BSE018335R1 connection unit with 8 relays
DSTD196P 3BSE018332R1 Connects to the Unit 8 Ch S100 I/O terminal unit
DSTD109P 3BSE018327R1 Connects to Unit 8 Ch S100 I/O terminal unit
ABB TC560V2 3BSE022178R1 Optical Modem
T8110B ICS Triplex Trusted TMR Processor
Enterasys SSA-G1018-0652 switchboard
SRFC4620C Inverter filter board
SR469-P5-HI-A20-E-H Motor management relay
SINT4611C Main circuit interface board
SDCS-PIN48-SD PULSE TRANSFORMER BOARD
SCXI-1302 Terminal block
SCXI-1160 General-Purpose Switch Module for SCXI
SCXI-1102 Voltage Input Module for SCXI
SCXI-1100 Voltage Input Module for SCXI
SC560 3BSE008105R1 Submodule Carrier incl local CPU
RXIIK 4 1MRK001643-AA Negative sequence overcurrent relay
RXEDK 2H 1MRK000841-KA Time Over/Under Voltage Relay
RVAR-5612 68260850 VARISTOR UNIT
RMIO-11C 68789010 CONTROL BOARD
REXROTH LT304 SN:882000119
REX B871NN-CS1B1 controller
REX010 HESG324426R0001 HESG324389 Earth Fault Protection Unit
PPD113 PPD103B101 3BHE020455R0101 3BHE023784R2630 controller
PP836 3BSE042237R1 PP836 Operator Panel
PP835A 3BSE042234R2 Touch Panel, 6.5″
SAIA PCD4.D1XX 463665500 Communication
PCD2.M110 Central processing units