Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
3500/15 133292-01 security controller
3500/25 184684-01 security controller
136188-01 PLC automation spare parts
RH924UQ Fiber optic network adapter
3500/92 136180-01 Communication gateway module (复制)
133300-01 Power input module
5417-1105 controller Communication function
531X301DCCAFG2 Modular controller
VMIVME 4140-000 CPU board VME bus
S70302-NANANA Servo amplifier
VMIVME 7459-112 Multifunctional memory module
VMIVME 2540-300 Motor detection module
131151-01 Channel relay output module
D201925 High precision hydraulic valve
CTB810 HN800 motor control medium-voltage
HDS03.2-W075N-HS12-01-FW R911190008 system
PM3398B-6P-1-3P-E 80026-172-23 coupler
58914444 NDPI-02 Series multilevel type
A413600 Crystalline silicon solar cells
A413331 ball wire pair High precision
D201471 Digital output module
D685EF-00 Power supply equipment
FV223-M2 Switch input module relay
D201466 input module Temperature monitoring
D201832 microcontroller Analog input module
D201190 input/output module
63025-01D Servo driver High performance
LDMUI-01 3AFE61320946P0001 Analog input module
PPC905AE101 3BHE014070R0101 Power module
XVC770BE101 3BHE021083R0101 board module
HIEE401782R0001 LTC391AE01 transformer
XVC768AE101 3BHB007211R0101 interface module
LDMTR-01 3BHB007445P0001 Optical coupler
UFC789AE101 3BHE014023R0101 Circuit breaker
3BHE024577R010 PPC907BE Reverse module
UAC383AE01 HIEE300890R0001 controller
DDC779BE02 3BHE006805R0002 controller
UFC762AE101 3BHE006412R0101 circuit breaker
XVC724BE 3BHE009017R0102 Monitoring system
XVC767AE102 3BHB007209R0102 Driving module
UFC760BE142 3BHE004573R0142 Circuit breaker
UFC760BE143 3BHE004573R0143 Circuit breaker
SW-1200063 Circuit breaker module
ACS5000 3BHB014024R0010 brushless DC motor driver manufactured
3BHL000606P0002 Modular controller
NMBA-01 3BHL000510P0003 Optical fiber network
D201134 Safety controller industrial control