Description
1. introduction
abb dcs is a distributed control system designed and developed by Swiss Asea Brown Boveri Company (abbreviated as abb company). It has a wide range of applications and can be used in discrete manufacturing industries
, such as machine tools, automobiles, aircraft manufacturing and other industries, as well as in large and medium-sized enterprises. Small-scale continuous production process industries, such as petroleum, chemical industry, thermal power units, steelmaking,
building materials and other industries. abb dcs system adopts international standards from hardware
design to software design and communication. The software programming language ampl (asea mas ter pi ece language) of abb dcs is a programming mode of the control system. This article introduces the architecture of abb dcs and its fieldbus network.
2 abb dcs distributed industrial control computer system architecture
abb dcs distributed control system uses advanced microprocessors (33mhz motorola 68020 and 33mhz intel 80386, 80486 chips), crt graphic display technology, high-speed safety communication technology and modern control theory to
form an on-site control station (mp200, ac410 , ac450 series and local and remote i/o series), operator station (as500 series), engineer station (master ai d series), information management system station (advant station series ), computer
and network interface station (master gate series), computer network (master bus series) and other computer communication equipment, it is a large-scale intelligent network with dispersed physical locations, dispersed system functions
, dispersed control functions, and centralized operation display management for process control and process decision-making management.
The communication network structure of abb dcs is divided into three layers:
3 Information Management Network Layer
It can be connected to 9 control networks. The network is composed of type mb300 bus, and the bus transmission rate reaches 10mbps.
4 Control network layer
The control network layer consists of 9 buses of type mb300. A control network may include 99 stations (including stations in local control networks). Each mp200/1 or ac450 station in the control network can be connected to a local control network.
A local control network can include 9 buses of type mb300. mb300 is a high-performance, serial, synchronous, half-duplex high-speed bus with large data volume. It adopts ieee 802.2 logical link control (llc) protocol and ieee 802.3 carrier frame listening
multiple access with conflict detection (csma/cd) media access control (mac) protocol. It is an ethernet type LAN and the bus
can carry loads . 45 nodes. When no repeater is used, the maximum communication node distance is 500m; when using 3 coaxial segments, 4 repeaters and 2 point-to-point links, the maximum communication node distance is 2500m, and the bus transmission rate is 10mbps.
mb300 realizes the connection to the host computer and communication with PLC systems such as MP200 through each node . It generally follows the 543 rule, that is, it is composed of 5 sections and 4 repeaters (repeater) connections, 3 of which can be
connected to equipment. It must be noted that only the marked prescription of the cable can be connected through the transceiver ( tranceiver ) Equipment, different equipment connections use different connection cables, such as tk526 cable to the pu510 operating station,
and tk576 cable to the control station. The tranceiver can only be installed at the 2.5-meter mark on the main cable section. The spacing between the tranceivers on the coaxial cable section between the two line joints should be an integer multiple of 25 meters. The connection method is as shown in the figure.
t1 and t2 are terminal resistors . As long as one end is grounded, the terminal resistance is 50 ohms. The mb300 bus is a coaxial cable. It is divided into thick cable, thin cable and optical cable. Their functions are different. When laying the coaxial cable, you need to
pay attention to it. Isolation from other signal cables, such as 30cm away from signal cables, 50cm away from 380v low-voltage cables, and 5m away from high-voltage cables. The mb300 bus uses the cs513 interface card. The three dial switches s1, s2, and s3 are
used to set the network number, node number, and protocol number respectively. The low four bits of s1 are used to set the master/slave station selection.
The high four bits are used to set the protocol number, s2 is used to set the node number, and s3 is used to set the network number. When it is necessary to modify or find out the cause of the fault through fault information, you can enter the engineering station to
modify the data or know the fault location of the mb300 bus through the fault code. Understand the communication factors that affect mb300 and analyze these factors one by one.
Display operation panel PFSK164
Display operation panel PFSK162 3BSE015088R1
Display operation panel PFSK162
Display operation panel PFSK160A 3BSE009514R1
Display operation panel PFSK160
Display operation panel PFSK152 3BSE018877R1
Display operation panel PFSK152 3BSE018877R1
Display operation panel PFSK152
Display operation panel PFSK151 3BSE018876R1
Display operation panel PFSK151 3BSE018876R1
Display operation panel PFSK151
Display operation panel PFSK142 3BSE006505R1
Display operation panel PFSK130 3BSE002616R1
Display operation panel PFSK102
Display operation panel PFSA146 3BSE008844R1
Display operation panel PFSA145 3BSE008843R1
Display operation panel PFSA140 3BSE006503R1
Display operation panel PFSA140 3BSE006503R1
Display operation panel PFSA140
Display operation panel PFSA103D
Display operation panel PFSA103C
Display operation panel PFRL101D-5KN
Display operation panel PFRL101D 5.0KN
Display operation panel PFRL101D
Display operation panel PFRL101C
Display operation panel PFRL101B-1.0KN
Display operation panel PFRL101B
Display operation panel PFRL101A-0.5KN 3BSE023314R0003
Display operation panel PFRL101A
Display operation panel PFRA101 3BSE003911R230
Display operation panel PFRA101
Display operation panel PFPA201 3BSE022827R1
Display operation panel PFPA201
Display operation panel PFEL113
Display operation panel PFEL112
Display operation panel PFEL111
Display operation panel PfeifferTPR280
Display operation panel PFEA113-65 3BSE050092R65
Display operation panel PFEA113-65 3BSE050092R65
Display operation panel PFEA113-65 3BSE028144R0065
Display operation panel PFEA113-65
Display operation panel PFEA113-65
Display operation panel PFEA113-20 3BSE050092R20
Display operation panel PFEA113-20 3BSE028144R0020
Display operation panel PFEA113-20
Display operation panel PFEA113
Display operation panel PFEA112-65 3BSE050091R65
Display operation panel PFEA112-65 3BSE030369R0065
Display operation panel PFEA112-65
Display operation panel PFEA112-20 3BSE050091R20
Display operation panel PFEA112-20
Display operation panel PFEA112-20
Display operation panel PFEA112
Display operation panel PFEA111-65 3BSE050091R65
Display operation panel PFEA111-65 3BSE050090R65
Display operation panel PFEA111-65 3BSE050090R65
Display operation panel PFEA111-65 3BSE028140R0065
Display operation panel PFEA111-65
Display operation panel PFEA111-65
Display operation panel PFEA111-65
Display operation panel PFEA111-20 3BSE050090R20
Display operation panel PFEA111-20 3BSE050090R20
Display operation panel PFEA111-20 3BSE028140R0020
Display operation panel PFEA111-20 3BSE028140R0020
Display operation panel PFEA111-20
Display operation panel PFEA111-20
Display operation panel PFEA111
Display operation panel PFEA101
Display operation panel PFCL301E
Display operation panel PFCL201CE-20KN
Display operation panel PFCL201CE
Display operation panel PFCL201C/CD
Display operation panel PFCL201C 10KN
Display operation panel PFCL201C 5KN 3BSE027070R5
Display operation panel PFCL201C 20KN
Display operation panel PFCL201C 10KN
Display operation panel PFCL201C
Reviews