Description
hardware flow control. It is an ideal choice in the field of industrial automation.
user experience
Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects
* cut costs
Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.
Implementation of communication between Omron vision system and ABB industrial robot
introduction
In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.
1Ethernet-based communication settings in vision software
The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.
First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.
After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.
2ABB industrial robot communication settings
First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.
Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
Pacific Scientific 105-090001-01 printed circuit board
Pacific Scientific 105-0730010-01 A printed circuit board
Pacific Scientific 105-072001-01 motion control panel
Pacific Scientific 105-070005-01 printed circuit board unit
Pacific Scientific 105-070001-05 circuit board
Pacific Scientific 105-050010 pc board
Pacific Scientific 105-050001-01 Simulation board
Pacific Scientific 105-040300-01 circuit board
Pacific Scientific 105-040200-02 motion control panel
Pacific Scientific 105-032002-01 motion control card
MMS 6720 With integrated output relay card
MMS 6710 Four channel isolation amplifier
MMS 6620 I/O card with 4 analog inputs
MMS 6418 Absolute-/ Relative Expansion Measuring Amplifier
MMS 6410 Two-channel displacement transducer
MMS 6312 Two-channel speed monitor
MMS 6310 Two-channel phase mark monitor
MMS 6220 Two-channel rotor eccentricity monitor
MMS 6120 Static Displacement Monitor
MMS 6140 Dual Channel Rotor Vibration Monitor
MMS 6140 Dual Channel Rotor Monitor
MMS 6125/10 Dual Channel Absolute Vibration Monitor
MMS 6125/00 Dual Channel Absolute Vibration Monitor
MMS 6120 Dual Channel Absolute Vibration Monitor
MMS 6110 Dual Channel Shaft Vibration Monitor
A6510 Signal Input Module
A6560RT Transient – Digital Condition Recorder
A6560R Prediction Processor
EZ1000 Eddy Current Converter
A6371/10 Backplane with slots for 3 measurement cards
A6371/00 Backplane with slots for 3 measurement cards
A6370D/DP 1 Channel Overspeed Protection Card
A6370D Channel overspeed protection card
A6500-FR Front Termination Rack
A6500-RR Redundant Relay Rack
A6500-SR System Rack
A6500-CC-P Package A6500-CC & A6500-PE
A6500-PE Prediction Extension License
A6500-CC System Communication Card
A6500-RC System Relay Card
A6500-UM Universal Measurement Card, Spee
P70530-SDN DC Microstepping Driver
P70530-PNN DC drive
P70360-SDN AC High Performance Microstep Driver
P70360-PNN Microstep AC Drive
S21260-VTS server Driver
S21260-SRS High performance servo drive
S20630-VTS server Driver
S20630-SRS server Driver
S20360-VTS-021 driver
S20360-VTS server Driver
S20360-SRS Brushless Servo Driver
S20360-CNS Node Servo Driver
S20350-VTS S200 Brushless Driver
S20350-CNS Node Servo Driver
S20330-VTS server Driver
Reviews
There are no reviews yet.