Description
hardware flow control. It is an ideal choice in the field of industrial automation.
Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
1900/65A-00-01-01-CN-00 Universal device monitor In stock
1900/65A-00-01-03-00-00 Universal Device monitor New original
1900/65A-00-00-01-00-00 Universal device monitor In stock
330100-50-05 Preprocessor sensor New original
143416-01 I/O module In stock
143416-01 Preprocessor sensor
18745-03 Preprocessor sensor
177314-02 Close to system test suite TK-3E
177314-01 Close to system test suite TK-3E
177313-02-02 Close to system test suite TK-3E
177313-02-01 Close to system test suite TK-3E
135613-03-00 High temperature enclosure expansion transducer assembly
135613-02-00 High temperature enclosure expansion transducer assembly
177313-01-02 Access to system test suite
135613-01-00 High temperature enclosure expansion transducer assembly
2300/20_KIT-001-02-00 Condition monitoring system suite
135613-01-00 High temperature enclosure expansion transducer assembly
125840-02 Ac power input module
126648-01 External terminal
106M1079-01 Ac power module
REF615E_E ABB HBFEAEAGABCCANC11E Protective relay
RET650 ABB Feeder protection terminal device
REF601 CE446BB1NH ABB Feeder protection terminal device
REG216 ABB Protective relay
REF615C_E ABB Feeder protection terminal device
REF610C11LCLR ABB Protective relay
REF545 ABB Feeder protection terminal device
REF541KM118AAAA ABB feeder terminal
REF543 ABB Protective relay
GJR5253100R0278 ABB Ethernet basic module
A06B-6290-H207 GE FANUC Servo amplifier module
GJR5252300R0101 ABB input/output module
GJR5253100R0278 ABB Ethernet basic module
07AC91 GJR5252300R0101 ABB input/output module
5X00489G01 EMERSON Power Distribution Module
IS420UCSBH4A GE controller module
E1421B HP Multifunctional switch/measuring unit
8715-CA-BI MTL Interface module
8502-BI-DP MTL Interface module
CMC16 200-530-025-014 Vibro-Meter Modular central processing card
IOCT16T 200-565-000-013 Vibro-Meter Modular central processing card
VRDM564/50LHA BERGER LAHR Schrittmotor
YPP105F ABB controller
X-AI3201 HIMA HART module
X-AO1601 HIMA HART module
X-DO1201 985210204 HIMA HART module
X-SB01 985210207 HIMA HART module
X-BLK01 632590802 HIMA HART module
X-DI1601 985210222 HIMA HART module
LM002_MAX 985020002 HIMA HART module
X-FAN1003 993201013 HIMA HART module
106M7607-01 Power Supply
Reviews
There are no reviews yet.