Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
LAM 810-068158-014 Analog output module
810-102361-222 LAM High frequency PCB board
LAM 810-800081-022 Board PC PCB card
PSR25-600-70 11КВТ ABB soft starter
E1421B HP Signal generator
KJ3001X1-CB1 DeltaV 32 channel module
MCU24.2 German EMG Input/output module
KJ3222X1-BA1 DeltaV™ Analog Input Card
IC200BEM003 GE VersaMax controller
3500/42M-01-00 BENTLY Seismic monitor
REOTRON 567LH-DP24 Driver module
REXA SMB9215-1E-1-7725 controller
Vibro-meter VM600 ABE040 System rack
Vibro-meter VM600 CMC16 Condition Monitoring Card
TRICONEX EMPII3005 TRICONEX PROCESSOR MODULE 3005
TRICONEX 3806E TRICONEX MODULE 3805E
TRICONEX 3721 TRICONEX MODULE
TRICONEX 3008 TRICONEX PROCESSOR MODULE ASSEMBLY MAIN PROC 860 16MEG
TRICONEX 3805H TRICONEX OUPUT MODULE 4-20MA ANALOGUE OUTPUT
TRICONEX 3511 TRICONEX INPUT MODULE PULSE
TRICONEX 3625 TRICONEX OUTPUT MODULE DIGITAL 24VDC 32POINT TMR ISOLATED
TRICONEX 3003-EMPII TRICONEX PROCESSOR MODULE V7 EMPII
TRICONEX 3750 TRICONEX PROCESSOR MODULE ENHANCED
TRICONEX 3611E TRICONEX MODULE DIGITAL OUTPUT 115VAC 8POINT
TRICONEX 3003 TRICONEX INPUT MODULE V7 EMP II 1MB
TRICONEX 3504E TRICONEX INPUT MODULE
TRICONEX 3624E TRICONEX MODULE
TRICONEX 3701 TRICONEX ANALOG INPUT MODULE TRICON V10.5
TRICONEX EICM4107 TRICONEX COMMUNICATION MODULE
TRICONEX 42003 TRICONEX FIBER OPTIC
TRICONEX 8112 TRICONEX EXPANSION CARD
TRICONEX 8110 TRICONEX CHASSIS HIGH DENSITY MAIN 10AMP 120VDC
TRICONEX 4507 TRICONEX MODULE V7 HIGHWAY INTERFACE
TRICONEX 3636T TRICONEX MODULE RO DRY CONTACT 32POINT SINGLE NO TUV
TRICONEX 3005 TRICONEX MAIN PROCESSOR MODULE EMPII V8
TRICONEX 42013 TRICONEX FIBER OPTIC
TRICONEX 8101 TRICONEX TRICON EXPANSION CHASSIS
TRICONEX 3007 TRICONEX PROCESSOR MODULE ENHANCED EMP II
TRICONEX 2554-6 TRICONEX TRICON SET TERM HDDI 24V C
TRICONEX 3004 TRICONEX PROCESSOR MODULE ENHANCED
TRICONEX 3603E TRICONEX DIGITAL OUTPUT MODULE
TRICONEX 4210 TRICONEX FIBER OPTIC
TRICONEX 3664 TRICONEX CPU MODULE
TRICONEX 8102 TRICONEX CHASSIS REMOTE EXTENDER RXSM