Sale!

TC561V2 3BSE022179R1 Using parameter ABB

Original price was: $1,888.00.Current price is: $1,688.00.

Model:TC561V2 3BSE022179R1

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:

Description

TC561V2 3BSE022179R1 Using parameter ABB
TC561V2 3BSE022179R1 Using parameter ABB
TC561V2 3BSE022179R1 Using parameter ABB Product details:
TC561V2 3BSE022179R1 is an interface communication module from ABB, with product model TC561V2 3BSE022179R1. This module is commonly used in industrial automation systems,
especially in the field of process control. Here are some possible application and product operation areas:
Industrial automation: ThTC561V2 3BSE022179R1 communication module may be used to communicate with other automation equipment, control systems,
or sensors to achieve automation and integration of industrial production lines.
Process control: This module may be used to monitor and control various processes, such as chemical plants, power plants, pharmaceutical plants,
etc. Through communication with other devices, it can achieve data exchange and control instruction transmission.
PLC (Programmable Logic Controller) systemTC561V2 3BSE022179R1 may be integrated into the PLC system for communication with other PLC modules or
external devices, achieving centralized management of the entire control system.
Data collection and monitoring: In the data collection systemTC561V2 3BSE022179R1 can be used to obtain data from various sensors and devices,
and transmit this data to the monitoring system for real-time monitoring and analysis.
Remote monitoring and operation: Through collaborative work with other communication modulesTC561V2 3BSE022179R1 may support remote monitoring and operation,

allowing operators to monitor and control the production process from different locations.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

ABB 1TGB120020P0003
ABB 1TGB120020P0002
ABB 1TGB120020P0001
ABB 1TGB120019P0013
ABB 1TGB120019P0012
ABB 1TGB120019P0004
ABB 1TGB120016P0801
ABB 1TGB120016P0800
ABB 1TGB120016P0603
ABB 1TGB120016P0601
ABB  1TGB120016P0600
ABB  1TGB120016P0401
ABB  1TGB120016P0400
ABB  1TGB120016P0109
ABB  1TGB120016P0064
ABB  1TGB120016P0063
ABB  1TGB120016P0062
ABB  1TGE120011R1502
ABB  1TGE120011R1510
ABB  1TGE120011R1511
ABB  1TGE120011R1512
ABB  1TGE120011R1520
ABB  1TGE120011R1521
ABB  1TGE120011R1522
ABB  1TGE120011R1600
ABB  1TGE120011R1601
1TGE120011R1610  ABB
1TGE120011R1611  ABB
1TGE120011R1612  ABB
1TGE120011R1620  ABB
1TGE120011R1621  ABB
1TGE120011R1622  ABB
1TGE120011R2000  ABB
1TGE120011R2001  ABB
1TGE120011R2002  ABB
1TGE120011R2010 ABB
1TGE120011R2011 ABB
1TGE120011R2012 ABB
1TGE120011R2020  ABB
1TGE120011R2021 ABB
1TGE120011R2022  Industrial module  ABB
1TGE106232N4250  Industrial module  ABB
HE693IBS100E  GE
HE693THM668E  GE
HE693THM884K  GE
HE693SNP900D  GE
HE693ADC816D  GE
HE693STP104  GE
HE693RTD720E  GE
HE693STP301E  GE
HE693PBM101E  GE
HE693ADC816A  GE
HE693RTD601R  GE
HE800DIQ616-B  GE
HE693RTD600R  GE
HE693ADC816C  GE
HE693OIU300  GE
HE693STP100H  GE
HE693STP100K  GE

Reviews

There are no reviews yet.

Be the first to review “TC561V2 3BSE022179R1 Using parameter ABB”

Your email address will not be published. Required fields are marked *