hardware flow control. It is an ideal choice in the field of industrial automation.
(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;
(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;
(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.
4 Inverter operation settings
After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.
After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.
4.1 Basic settings
(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.
(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.
(3) 51.03—This parameter is Profibu
The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.
(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]
4.2 Connection of process parameters
The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.
(1) PZD value sent from PLC to transmission inverter
PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;
PZD2—frequency setting value of the inverter.
(2) PZD value sent from the transmission inverter to the PLC
PZD1—status word, such as alarm, fault and other inverter operating status;
PZD2—actual speed value, current actual value, etc. of the frequency converter.
5 Conclusion
After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.
New technology from Swiss ABB Group: Complete car charging in 15 seconds
This technology can charge a car in 15 seconds
The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.
ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.
The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.
ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.
ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”
9907-205 Woodward Hand Held Programmer
9907-252 Woodward Load Sharing Module
81001-450-53-R Allen-Bradley CIRCUIT BOARD
9907-838 Woodward Load Sharing Module
DSQC639 3HAC025097-00116 ABB Main computer
3500/15 Bently Nevada height modules
DCF803-0035 ABB agnetic field exciter
E22SSLT-LNN-NS-04 KOLLMORGEN Hybrid stepping motor
EL3020 ABB EasyLine Continuous Gas Analyzers
F7553 HIMA Coupling Module
FI830F ABB Fieldbus Profibus DP
IC687RCM711 GE redundancy communications module
H92 FOXBORO Controller module
MVI56-PDPS Allen-Bradley PROFIBUS DP I/O Slave Network Interface
IC690RFH008 GE 8 MULTIMODE REFLECTIVE MEMORY HUB
NBRA-669C ABB Universal Brake Chopper
PFTL101A 2.0KN ABB Load cell
PM867K01 ABB controller module
PFTL101B 2.0KN 3BSE004185R1 ABB Load cell
PP826 3BSE042244R1 ABB PROFIBUS DP Panel 800
PU516A 3BSE032402R1 ABB Engineering board
V4550220-0100 ABB CONTROL PRECIPITATOR
VMIVME-017807-413000 GE Pentium processor
Z7116 HIMA Front connector
3HNA025019-001 ABB PROSESS IO APIP-05A
216NG63A ABB Controller module
216VC62a ABB Processor Unit Relay Card
05704-A-0145 HONEYWELL Four Channel Control Card 4 – 20mA Input
DSDI110AV1 3BSE018295R1 ABB Digital Input Board
DSDO115A 3BSE018298R1 ABB Digital Output Board 32 Channe
DSQC663 E3HAC029818-001 ABB HV MDU Power unit
DSDO120 57160001-AK ABB PLC Module
DSRF197 3BSE019297R1 ABB Equipment Frame
IC698ETM001 GE Ethernet interface module
IC698RMX016 VMIVME-5567-100 GE Redundant Memory Exchange Module
IS215UCVGM06A IS215UCVGH1A VMIVME-7666-111000 GE Mark VI printed circuit board
363A4940CSP5 IS220PAOCH1A GE MARK Vie ANALOG INPUT/OUPUT MODULE
IS230SNRTH2A GE Input/turbine control system
IS220PPRFH1B 336A5026ADP2 GE Master Gateway I/O Module
KJ3242X1-BK1 12P4711X052 EMERSON Controller module
PFCL201C 10KN ABB Pressductor PillowBlock Load cells
PFSK130 3BSE002616R1 ABB Channel Control Unit
PM632 3BSE005831R1 ABB Processor Unit
PM645B ABB Series 60 Advant Controller