Sale!

SC510 3BSE003832R1 DCS excitation system

Original price was: $1,888.00.Current price is: $1,688.00.

Model:SC510 3BSE003832R1

New original warranty for one year

Brand: ABB

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:

Description

Product parameters
Model: SC510 3BSE003832R1
Brand: ABB
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
SC510 3BSE003832R1 is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
SC510 3BSE003832R1 is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: SC510 3BSE003832R1 Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install SC510 3BSE003832R1 correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating SC510 3BSE003832R1 to ensure proper use.
Product Introduction
SC510 3BSE003832R1 is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

3.3 Design of computer control software

This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.

The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.

3.4 Design of touch screen software

The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.

3.5 Design of PLC software

As the core of this control system, PLC is mainly responsible for the following aspects:

Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.

Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.

It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.

Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface

3.6 Frequency converter settings

In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:

Switch the control mode to local control and set the inverter address according to the inverter user manual.

Set the inverter for remote control and select the communication mode.

Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.

Set the speed control mode of the inverter, such as speed control or torque control.

After completing the basic parameter settings, switch to the remote control state and wait for remote control.

4 Conclusion

This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

Excitation system ABB module DSAI130A
Excitation system ABB module DSAI130A
Excitation system ABB module DSAI-130/57120001-P
Excitation system ABB module DSAI130 ABB
Excitation system ABB module DSAI130 57120001-P
Excitation system ABB module DSAI130 57120001-P
Excitation system ABB module DSAI130
Excitation system ABB module DSAI130
Excitation system ABB module DSAI130
Excitation system ABB module DSAI-110 57120001-DP/2
Excitation system ABB module DSAI110
Excitation system ABB module DSAB-01C
Excitation system ABB module DSAB01C
Excitation system ABB module DSAB-01
Excitation system ABB module DRA02
Excitation system ABB module DPW01
Excitation system ABB module DPT160-CB011
Excitation system ABB module DP910S
Excitation system ABB module DP910N
Excitation system ABB module DP910B
Excitation system ABB module DP840-eA
Excitation system ABB module DP840
Excitation system ABB module DP840
Excitation system ABB module DP820-eA
Excitation system ABB module DP820
Excitation system ABB module DP820
Excitation system ABB module DO930N
Excitation system ABB module DO910S
Excitation system ABB module DO910N
Excitation system ABB module DO910B
Excitation system ABB module DO890
Excitation system ABB module DO890
Excitation system ABB module DO880 3BSE028602R1
Excitation system ABB module DO880
Excitation system ABB module DO840-eA
Excitation system ABB module DO840
Excitation system ABB module DO840
Excitation system ABB module DO828-eA
Excitation system ABB module DO821-eA
Excitation system ABB module DO821
Excitation system ABB module DO821
Excitation system ABB module DO820-eA
Excitation system ABB module DO820/3BSE008514R1
Excitation system ABB module DO820 3BSE008514R1
Excitation system ABB module DO820
Excitation system ABB module DO820
Excitation system ABB module DO820
Excitation system ABB module DO820
Excitation system ABB module DO818-eA
Excitation system ABB module DO818
Excitation system ABB module DO815-eA
Excitation system ABB module DO815
Excitation system ABB module DO815
Excitation system ABB module DO814-eA
Excitation system ABB module DO814
Excitation system ABB module DO814
Excitation system ABB module DO810-eA
Excitation system ABB module DO810 3BSE008510R1
Excitation system ABB module DO810 3BSE008510R1
Excitation system ABB module DO810
Excitation system ABB module DO810
Excitation system ABB module DO810
Excitation system ABB module DO810
Excitation system ABB module DO802-eA
Excitation system ABB module DO802
Excitation system ABB module DO802
Excitation system ABB module DO801-eA
Excitation system ABB module DO801  3BSE020510R1
Excitation system ABB module DO801
Excitation system ABB module DO801
Excitation system ABB module DO801

Reviews

There are no reviews yet.

Be the first to review “SC510 3BSE003832R1 DCS excitation system”

Your email address will not be published. Required fields are marked *