Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
Display operation panel AI210
Display operation panel AI04
Display operation panel AI03
Display operation panel AI02J
Display operation panel AGPS-21C
Display operation panel AGPS21C
Display operation panel AFC094AE2 HIEE200130R0002
Display operation panel AFC094AE02
Display operation panel AFC094AE02
Display operation panel AE6003B GNT0116800R0001
Display operation panel ACU-01B 3HNA024871-001
Display operation panel ACU-01B 3HNA024871-001/03
Display operation panel ACU-01B 3HNA024871-001
Display operation panel ACU-01B 3HNA024871-001
Display operation panel ACU-01B 3HNA024871-001
Display operation panel ACU-01B
Display operation panel ACS-BRK-D
Display operation panel ACBU-A2 3AUA0000125090
Display operation panel ACBU-A1
Display operation panel AC900F PM902F
Display operation panel AC800PEC PPD512
Display operation panel AC722F
Display operation panel AC389AE01 HIEE300888R0001
Display operation panel ABBPP846A
Display operation panel ABB-EL3020
Display operation panel AB91-1 HESG437479R1 HESG437899
Display operation panel AB7006-B
Display operation panel 89NG03
Display operation panel 89AR30/R0100
Display operation panel 88QB03B-E GJR2393800R0100
Display operation panel 83SR11E
Display operation panel 83SR05E
Display operation panel 81ET03
Display operation panel 81AB01E GJR2342600R1000
Display operation panel 81943A041-1
Display operation panel 81943A041-1
Display operation panel 81943A041
Display operation panel 8025-235
Display operation panel 800PP846A
Display operation panel 7ML52020EA0
Display operation panel 70AA02b-E HESG447388R1
Display operation panel 61615-0-1200000
Display operation panel 5SYN-5100A-Z,V221 3BHB006717R0221
Display operation panel 5SHY6545L0001 AC10272001R0101
Display operation panel 5SHY55L4500
Display operation panel 5SHY55L4500
Display operation panel 5SHY50L5500
Display operation panel 5SHY5055L0002 3BHE019719R0101 GVC736BE101
Display operation panel 5SHY5055L0002 3BHE019719R0101
Display operation panel 5SHY5055L0002 3BHE019719R0101
Display operation panel 5SHY5045L0020
Display operation panel 5SHY42L6500
Display operation panel 5SHY42L6500
Display operation panel 5SHY40L4511
Display operation panel 5SHY4045L0006 3BHB030310R0001
Display operation panel 5SHY4045L0006 3BHB030310R0001
Display operation panel 5SHY4045L0006 3BHB030310R0001
Display operation panel 5SHY4045L0006
Display operation panel 5SHY4045L0004 3BHB021400R0002
Display operation panel 5SHY4045L0004 3BHB021400R0002
Display operation panel 5SHY4045L0004 3BHB021400R0002
Display operation panel 5SHY4045L0004
Display operation panel 5SHY4045L0003 3BHB021400
Display operation panel 5SHY4045L0001 3BHB018162R0001
Display operation panel 5SHY4045l0001 3BHB018162R0001
Display operation panel 5SHY4045L0001
Display operation panel 5SHY35L4522
Display operation panel 5SHY35L4521
Display operation panel 5SHY35L4520 5SXE10-0181
Display operation panel 5SHY35L4520
Display operation panel 5SHY35L4520
Display operation panel 5SHY35L4512
Display operation panel 5SHY35L4510 IGCT模块驱动板
Display operation panel 5SHY35L4510 3BHE014105R0001
Display operation panel 5SHY35L4510
Reviews
There are no reviews yet.