Description
REF615C_C HCFFAEAGANB2BAN1XC Использование параметров ABB
Швейцария, и входит в десятку крупнейших швейцарских транснациональных корпораций.REF615C_C HCFFAEAGANB2BAN1XC
химическая, нефтехимическая, фармацевтическая, целлюлозно – бумажная, нефтепереработка; Оборудование приборов: электронные приборы, телевизоры и оборудование для передачи данных,
генераторы, гидротехнические сооружения; Каналы связи: интегрированные системы, системы сбора и распространения;REF615C_C HCFFAEAGANB2BAN1XCСтроительная промышленность: коммерческое и промышленное строительство.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
223BD-00001AAB MKS Baratron Pressure Transducer
CB801 3BSE042245R1 ABB Profibus DP Communication Interface
3BHB003688R0001 ABB Module
REM615E_1G ABB FEEDER PROTECTION AND CONTROL RELAY
CS513 3BSE000435R1 ABB 802.3 LAN-Module
136188-01 Bently Nevada Communication Gateaway Module
3500/25 184684-01 Bently Nevada Enhanced Keyphasor Module
3500/05-01-03-00-00-00 Bently Nevada 3500/05 System Rack
3500/44M 176449-03 Bently Nevada Aeroderivitive GT Vibration Monitor
UR8FH GE Universal Relays of the UR Series
3500/32 125712-01 Bently Nevada 4-channel relay module
3500/40M 140734-01 Bently Nevada Proximitor monitor I / O module
3500/40M 176449-01 Bently Nevada Proximitor Monitor
3500/42M 176449-02 Bently Nevada Proximitor/Seismic Monitor
125680-01 Bently Nevada Proximitor I/O Module
CE4003S2B6 Emerson Standard I/O Termination Block
F8620/11 HIMA CPU Module
FS7-2173-2RP HONEYWELL FS7 Multispectral Fire and Flame Detector
IC698PSA100D GE power supply module
PCI354-1022-38 02088-019 Jasper Electronics Processor module
BAB-740 11887 REV F PMCE-740 REV B.202012230809379 ELTEC
SST-DN3-PCI-2 DSQC658 SST ingle channel robot graphics card
UFC760BE43 3BHE004573R0043 ABB DCS / PLC system module
SK829007-B ABB RC surge suppressor
UR8AH GE Universal Relay UR Series
FBM232 P0926GW Foxboro Ethernet Communication Module
6ES7972-0BA60-0XA0 SIEMENS DP bus connector
VMIVME-5565 GE Ultra-high-speed optical fiber reflective memory
KUC755AE106 3BHB005243R0106 ABB Portal crane power exciter control module
UR6UH GE Digital input / output module universal relay ur series
E33NCHA-LNN-NS-00 Pacific Scientific Hybrid Step Motor in the E Series
JANCD-XCP0101C-1 YASKAWA Controller Board
CPS-150F YASKAWA Power Supply
PP825 3BSE042240R1 ABB Panel 800 Operator Panel
3500/42M 176449-02 Bently Nevada Proximitor/Seismic Monitor
DECS-200-2L BASLER ELECTRIC Digital Excitation Control System
OCAHG492838402 ABB PLC circuit board
SC-UCMX01 51307195-175 HONEYWELL RTU2020 CONTROLLER
OCAHG 492838402 ABB Analog output 4ch
OCAH 940181103 ABB Output panel
1746-NO4VA A-B SLC 500 Analog Output Module
NDCU-12C NDCU-12CK ABB DRIVE CONTROL UNIT
CB06551 PRD-B040SSIB-63 KOLLMORGEN SERVO DRIVE
FC-PSU-UNI2450U V1 Honeywell Power Supply Module
MOX12-P3509 B 80026-173-23 ABSOLUTE POWER SUPPLY
TP854 3BSE025349R1 ABB Baseplate
XV-440-10TVB-1-20 EATON ELECTRIC Terminal Tactil 10.4″
VMIVME-7455 GE Standard VME double height Eurocard
UR6DH GE Digital I/O Input Output UR Series Universal Relay Module
VMIVME-4140 GE 16-Channel 12-bit Analog Output Board
Reviews