Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
940860010102-VBM030 Ultrasonic diagnostic instrument
51403645-100-SBHM Power control board module
51402455-100-MP-DNCF02-200 Honeywell
51402455-100 MP-DNCF02-200 Power module
51304650-100 HONEYWELL Industrial pressure sensor
51303940-150 Honeywell Cabinet fan assembly with alarm
8141649.53 Main board SEW
8100183 Dual process segment controller KONGSBERG
4000093-110N Bolt type terminal connection
3171197-4 B&w Man-machine interface panel
10313/1/1 Honeywell Terminal module
1030211 Relay module PLC-RPT- 24DC/21
822675X.13.17 servo motor
805405-1R Power module unit
395566-003 HP Server motherboard
3500/44M 176449-03 Speed sensor Bently
3500/42M-01-00 Speed monitor Bently Nevada
3500/33 Bently Nevada 149986-01 preamplifier
3500/33 Bently Nevada preamplifier
3500/25 Bently Nevada Accelerometer sensor
3500/25 149369-01 Speed sensor Bently
350022M-288055-01 Transient data interface Bently
3500/15 Power module Bently Nevada
3500/05-02-04-00 bently Monitoring vibration
330180-51-00 bently preprocessor
330180-50-00 5/8 mm proximity sensor
330105-02-12-05-02-05 Bentley Reverse mounting probe
Bently 330100-90-01 Vibration sensor
330016-11-01-03-00-00-01 BENTLY NEVADA
2300/25-00 BENTLY monitor module
192061B-02 NI acquisition card data connection cable
190065A-01-01-01-00-00 Universal equipment monitor
146031-01 Transient data interface I/O module
140734-01 4-channel monitor Bently
133442-01 Output module Bently
129478-01 High DC power input
128275-01-E Seismic monitor module
125720-01 Bently Nevada channel relay module
086349-002 Measuring Pcb Circuit board
ABB 086329-004 PWA,ECS,END COL
81943A041 Amplifier TC assy
80190-380-01-R Rectifier/charger
80026-044-06-R Power switching module
65040-PACV-AYU2 Control swing valve
41391-454-01-S1FX Control module Allen-Bradley
24765-02-00 Casing expansion sensor system
10350-00104 Ethernet connection Connect.
10244-27-50-01 Liquid level sensor
9907-1183 Control of various turbines
9907-167 Digital regulator control
Reviews
There are no reviews yet.