Nine Questions and Answers on Common Faults in ABB Industrial Robot Applications
Question 1: Under what circumstances do I need to back up my robot?
Answer: 1. After the new machine is powered on for the first time.
2. Before making any modifications.
3. After completing the modification.
4. If the robot is important, conduct it regularly once a week.
5. It is best to make a backup on a USB flash drive.
6. Delete old backups regularly to free up hard drive space.
Second question: What does the alarm message 10106 maintenance time reminder mean when the robot appears?
Answer: This is the intelligent periodic maintenance reminder of ABB robots.
Question 3: What should I do if the robot enters a system failure state when it is powered on?
Answer: 1. Restart the robot.
2. If it doesn”t work, check whether there is a more detailed alarm prompt on the teaching pendant and handle it.
3. Restart.
4. If it still cannot be lifted, try B startup.
5. If it still doesn’t work, try P startup.
6. If it still doesn’t work, try I startup (this will return the robot to factory settings, be careful).
Question 4: Can robot backup be shared by multiple robots?
Answer: No, for example, the backup of robot A can only be used for robot A, not robots B or C, because this will cause system failure.
Five questions: What files can be shared in the robot backup?
Answer: If the two robots are of the same model and configuration. You can share RAPID programs and EIO files, but they must be verified before they can be used normally.
Question 6: What is the mechanical origin of the robot? Where is the mechanical origin?
Answer: The six servo motors of the robot have a unique fixed mechanical origin. Incorrectly setting the mechanical origin of the robot will cause problems such
as limited movement or malfunction of the robot, the inability to walk in a straight line, etc., and serious damage to the robot.
Question 7: How to cancel the robot 50204 motion monitoring alarm?
Answer: 1. Modify the robot action monitoring parameters (control panel – action monitoring menu) to match the actual situation.
2. Use the AccSet command to reduce the robot”s acceleration.
3. Reduce the v_rot option in the speed data.
Eight questions: What should I do if the robot alarms “50296, SMB memory data difference” when it is powered on for the first time?
Answer: 1. Select calibration in the ABB main menu.
2. Click ROB_1 to enter the calibration screen and select SMB memory.
3. Select “Advanced” and click “Clear Control Cabinet Memory” after entering.
4. Click “Close” when finished, then click “Update”.
5. Select “The control cabinet or robot has been exchanged, and the control cabinet is updated using SMB memory data.”
Question 9: How to customize the speed of robot trajectory in the RAPID program?
Answer: 1. Select program data in the main menu of the teaching pendant.
2. After finding the data type Speeddata, click New.
3. Click on the initial value. The meanings of the four variables of Speeddata are: v_tcp represents the linear operating speed of the robot, v_rot
represents the rotational operating speed of the robot, v_leax represents the linear operating speed of the additional axis, v_reax represents the rotational
operating speed of the additional axis, if there is no additional axis, then No need to modify the two.
4. The customized data can be called in the RAPID program.
Control module DCS system spare parts TB806
Control module DCS system spare parts TB805
Control module DCS system spare parts TB711F
Control module DCS system spare parts TB521-ETH
Control module DCS system spare parts TAS01
Control module DCS system spare parts TAS.580.0600G00 V01
Control module DCS system spare parts TAS.580.0560G00
Control module DCS system spare parts TAS.580.0540G00
Control module DCS system spare parts TA924F
Control module DCS system spare parts TA724F
Control module DCS system spare parts TA526
Control module DCS system spare parts TA525
Control module DCS system spare parts TA524
Control module DCS system spare parts TA523
Control module DCS system spare parts SYNPOLD CMA132
Control module DCS system spare parts SYNCHROTACT5 3BHB006713R0217
Control module DCS system spare parts SYN5202A
Control module DCS system spare parts SYN5202
Control module DCS system spare parts SYN5201a-Z,V217 3BHB006714R0217
Control module DCS system spare parts SY809F
Control module DCS system spare parts SY809F
Control module DCS system spare parts SV541
Control module DCS system spare parts STT02E
Control module DCS system spare parts STC2BE
Control module DCS system spare parts STC2AE
Control module DCS system spare parts STBNIP2311
Control module DCS system spare parts SS832 3BSC610068R1
Control module DCS system spare parts SS832
Control module DCS system spare parts SS832
Control module DCS system spare parts SS832
Control module DCS system spare parts SS832
Control module DCS system spare parts SS822Z
Control module DCS system spare parts SS822
Control module DCS system spare parts SR511 3BSE000863R1
Control module DCS system spare parts SR511 3BSE000863R0001
Control module DCS system spare parts SPTPS13
Control module DCS system spare parts SPTKM01
Control module DCS system spare parts SPSET01
Control module DCS system spare parts SPSET01
Control module DCS system spare parts SPSED01
Control module DCS system spare parts SPNPM22
Control module DCS system spare parts SPNPM22
Control module DCS system spare parts SPNPM22
Control module DCS system spare parts SPNIS21
Control module DCS system spare parts SPNIS21
Control module DCS system spare parts SPNIS21
Control module DCS system spare parts SPNIS21
Control module DCS system spare parts SPMC2402
Control module DCS system spare parts SPMC1402
Control module DCS system spare parts SPIPT800
Control module DCS system spare parts SPIET800
Control module DCS system spare parts SPIET800
Control module DCS system spare parts SPIET800
Control module DCS system spare parts SPICT13A
Control module DCS system spare parts SPHSS13
Control module DCS system spare parts SPHSS13
Control module DCS system spare parts SPHSS13
Control module DCS system spare parts SPHSS03 Belica piece
Control module DCS system spare parts SPHSS03
Control module DCS system spare parts SPFEC12
Control module DCS system spare parts SPFEC12
Control module DCS system spare parts SPFEC12
Control module DCS system spare parts SPFEC12
Control module DCS system spare parts SPFCS01
Control module DCS system spare parts SPER1C1
Control module DCS system spare parts SPDSO14
Reviews
There are no reviews yet.