Sale!

PM866AK02 3BSE081637R1 Using parameter ABB

Original price was: $1,888.00.Current price is: $1,688.00.

Model:PM866AK02 3BSE081637R1

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:

Description

PM866AK02 3BSE081637R1 Using parameter ABB
PM866AK02 3BSE081637R1 Using parameter ABB
PM866AK02 3BSE081637R1 Using parameter ABB Product details:
PM866AK02 3BSE081637R1 is an interface communication module from ABB, with product model PM866AK02 3BSE081637R1. This module is commonly used in industrial automation systems,
especially in the field of process control. Here are some possible application and product operation areas:
Industrial automation: ThPM866AK02 3BSE081637R1 communication module may be used to communicate with other automation equipment, control systems,
or sensors to achieve automation and integration of industrial production lines.
Process control: This module may be used to monitor and control various processes, such as chemical plants, power plants, pharmaceutical plants,
etc. Through communication with other devices, it can achieve data exchange and control instruction transmission.
PLC (Programmable Logic Controller) systemPM866AK02 3BSE081637R1 may be integrated into the PLC system for communication with other PLC modules or
external devices, achieving centralized management of the entire control system.
Data collection and monitoring: In the data collection systemPM866AK02 3BSE081637R1 can be used to obtain data from various sensors and devices,
and transmit this data to the monitoring system for real-time monitoring and analysis.
Remote monitoring and operation: Through collaborative work with other communication modulesPM866AK02 3BSE081637R1 may support remote monitoring and operation,

allowing operators to monitor and control the production process from different locations.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

SE4003S2B1 Analog Input Card 8 Channel Assembly
SE4002S1T2B1 Discrete Output Card
SE4002S1T1B1 Discrete Output Card 8 Channel Assembly
SE4001S2T2B1 Discrete Input Card 8 Channel Assembly
KJ3246X1-BA1 Fieldbus H1 With Intergrated Power
KJ4006X1-BQ1 S-Series Profibus DP Terminal Block
KJ3222X1-BK1 AI 8-Channel 4-20 mA HART Card
KJ3209X1-BK1 Digital Output Module
KJ3221X1-BK1 AO 8-Channel 4-20 mA HART Card
KJ3208X1-BK1 Digital Output Module
KJ3208X1-BK1 Digital Output Module
KJ3202X1-BK1 Discrete Output Card
KJ3201X1-BK1 Digital Input NAMUR Module
KJ3243X1-BK1 S-Series Profibus DP Card
KJ2006X1-BK1 Virtual I/O Module
KJ1501X1-BK1 Power Supply
KJ1501X1-BK1 Power Supply
KJ4001X1-CB1 Fused I/O Terminal Block
KJ4001X1-CA1 I/O Terminal Block
KJ4001X1-BB1 Carrier Rack
KJ4001X1-CA1 I/O Terminal Block
KJ3001X1-BA1 Digital Input Isolated
KJ3001X1-BG1 Digital Output Isolated
KJ3001X1-BG1 12P0557X13 Digital Output Isolated
KJ3001X1-BK1 DeltaV Output Module
KJ3001X1-BH1  DeltaV Discrete Output Module
KJ3001X1-BG1 Discrete Output Card DeltaV
KJ3001X1-BD1 DeltaV Discrete Input Card
KJ3001X1-BB1 DeltaV Discrete Input Card
KJ3001X1-BA1 DeltaV Input Module
KJ2201X1-JA1 DeltaV SLS Redundant Terminal Block
KJ2201X1-BA1 SLS 1508 eltaV Logic Solver
KJ2101X1-BA1 DeltaV Provox Input Output Interface Card
KJ2004X1-BA1 DeltaV Remote Interface Unit
KJ2002X1-BA1 VE3002 DeltaV Controller M3
KJ2001X1-BA1 DeltaV Controller M2
KJ1502X1-BB2 DeltaV System Power Supply
KJ1501X1-BC1 DeltaV System Power Supply
KJ1501X1-BB1 DeltaV Power Supply
VE5001 KJ1501X1-BA2 DeltaV System Power Supply
Ovation 1C31233G04 Event Sequence card
Ovation 1C31234G01 Compact contact input module
Ovation 1C31238H01 Digital Input module
Ovation 1X00024H01 Magnetic power module
Ovation 1X00416H01 Analog current input unit
Ovation 1X00781HO1L DIN guide power module
Ovation 38B5786X132 Pneumatic relay
Ovation 5X00058G01 Analog input module
GE VMIVME-7740-850 350-007740-850 L Processor Module
A-B 1747-L541 Controller module
Allen-Bradley 22B-D010N104 PowerFlex 4 Variable frequency drive
REXROTH BTV04.2GN-FW Microcontrol panel
GE DS3800DFXA1B1C DIGITAL SPEEDTRONIC IN/OUT GE BOARD
GE HE693ADC409A-22 Millivolt Analog I/O Module
IEMMU21 ABB Module Mounting Unit

Reviews

There are no reviews yet.

Be the first to review “PM866AK02 3BSE081637R1 Using parameter ABB”

Your email address will not be published. Required fields are marked *