Sale!

PM866AK01 3AUA0000052519 Использование параметров ABB

Original price was: $1,888.00.Current price is: $1,688.00.

МодельPM866AK01 3AUA0000052519

Первоначальная гарантия на один год.
PM866AK01 3AUA0000052519 Параметры

PM866AK01 3AUA0000052519 Размер 30 * 20 * 30
PM866AK01 3AUA0000052519 Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

PM866AK01 3AUA0000052519 Использование параметров ABB
PM866AK01 3AUA0000052519 Использование параметров ABB
PM866AK01 3AUA0000052519 Использование параметров ABB Product details:
PM866AK01 3AUA0000052519Поддержка одной платы связи и четырех разъемов IO; Поддерживает протоколы связи Modbus TCP, ProfiNet, EtherCAT, EtherNet / IP,

CC – Link и другие. Каждый слот IO может быть выбран автономно в соответствии с потребностями клиента, а один модуль поддерживает до 16 каналов.

Технологии основаны на инновацияхPM866AK01 3AUA0000052519 Предоставление клиентам высококачественных и надежных продуктов всегда было постоянным стремлением к нулю.

Давайте посмотрим на его инновации и различия с предшественниками: с жидкокристаллическим дисплеем, вы можете увидеть параметры связи, состояние канала IO,

информацию о версии модуля и так далее; PM866AK01 3AUA0000052519 Отладка и обслуживание более интуитивно понятны; ABS огнестойкая пластиковая оболочка, небольшой размер,

легкий вес, с использованием совершенно новой пряжки монтажной карты, установка более прочная и надежная.

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”


330905-00-09-05-02-05 3300 NSv Proximity Probes
330103-00-13-10-02-05  3300 XL 8 mm Proximity Probes
125565-01  Half-height Blank Front Panel Cover (Spares)
330103-17-22-10-02-05 3300 XL  Proximity Transducer System
131151-01  Half-height Blank Front Panel Cover (Spares)
3500/22-01-01-R0 Bently Nevada  Transient Data Interface
3500/25-01-05-R0  Enhanced Keyphasor Module
3500/62-04-R0 Bently Nevada  Process Variable Monitor
REF615E-1G  ABB  Feeder Protection and Control
1756-PA7585-265V Allen-Bradley ControlLogix Power Supply
IS200DSPXH1DBD  GE  printed circuit board
IS200ERDDH1ABB  GE  Mark VI Speedtronic system
MM-6702 REVA P/N 2000795  Micro  Memory Board
PT-VME330B  16 – Port Synchronous Communications Controller
ACS580-01-073A-4 ABB  LV AC general purpose drive module
ACS580-01-430A-4 ABB  LV AC general purpose drive module
ACS580-04-650A-4  ABB  LV AC general purpose drive module
3500/25-01-05-00  Bently Nevada Enhanced Keyphasor Module
REF615 HBFJAEAGABC2BAA11G  Feeder Protection and Control
AKM52K-ACCNR  KOLLMORGEN  AKM™ Series Servo Motor
330180-90-00  Bently Nevada 3300 XL Proximitor Sensor
330105-02-12-05-02-00  Bently Nevada Reverse Mount Probes
80190-100-01-R  Allen-Bradley  OPTICAL INTERFACE BASE PCB
IC693PWR321R  GE  Standard Power Supply module
80190-600-01-R  Allen-Bradley  OPTICAL INTERFACE BASE PCB
1746-NI8  Allen-Bradley  SLC 500 Analog I/O Module
PCI-4472  778348-01  NI  Sound and Vibration Device
P0926GH  FBM224/230  Communication Input Interface Module
2080-LC50-24QWB  Micro 850 Programmable Logic Controller
FBM242  P0916NG   Discrete Output Interface Module
VMIVME-7750-740000  VME Single Board Computer
REU610CVVHCNP01  ABB  Voltage relay  system
MIVII1000E00HI00  GE  Universal relay
JZRCR-YPP01-1 YASKAWA  Motoman Programming Pendant
5069-L310ERS2  SIL 2 type of CompactLogix 5069 controller
VTR-5-NB  DEIF  Bridge wing indicator
CX1020-0000  BECKHOFF  Embedded controller
SE4006P2  EMERSON  DeltaV™ Controller Redundancy
1756-OW16I/A  ControlLogix Discrete output module
KJ4010X1-BC1  DeltaV™ Electronic Marshalling for Migrations
1794-IT8   Allen-Bradley  Flex I/O analog input module
SE5009  EMERSON  S-series DC to DC System Power Supply
1756-L72EROMS  specialized industrial controller
IKR060  Cold cathode gauge  Pfeiffer Inficon
LMC078CECS20T Schneider motion controller
SCE903A3-002-01 High Performance Digital Servo Drive
WOODWARD EGCP-3 8406-113 Digital Control Interface Panel
WOODWARD 9907-164 505 and 505E Governor control units
8200-1300 Integrated multi-language interface HMI screen  Woodward
WOODWARD 8237-1600 ProTech-GII Overspeed detection System
WOODWARD 8701-758 5601-1126 Electro-hydraulic converter A very practical converter
HCS03.1E-W0210-A-05-NNBV  Rexroth  HCS Compact Converters
EPRO PR6426/010-010+CON021/916-160 Eddy current sensor
EPRO PR6423/010-010+CON021 axis displacement sensor

Reviews

There are no reviews yet.

Be the first to review “PM866AK01 3AUA0000052519 Использование параметров ABB”

Your email address will not be published. Required fields are marked *