Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
A-B 1747-L541 Controller module
Allen-Bradley 22B-D010N104 PowerFlex 4 Variable frequency drive
REXROTH BTV04.2GN-FW Microcontrol panel
GE DS3800DFXA1B1C DIGITAL SPEEDTRONIC IN/OUT GE BOARD
GE HE693ADC409A-22 Millivolt Analog I/O Module
IEMMU21 ABB Module Mounting Unit
HONEYWELL FC-SDOL-0424 Digital output module
871TM-BH8N18-N3 Inductive Sensor
GJR5252300R3101 07AC91F Analog I/O Unit
BENTLY 330101-23-39-10-12-CN sensor
PR6424/010-010+CON021 Shaft vibration sensor probe
Woodward 9907-018 2301A Forward Acting Speed Control
SYN5202-0271 ABB Synchronous device
ACU-01B 3HNA024871-001 Paint Robots
Agilent E1422A Remote Channel Multi-function DAC Module
Agilent E1460A 64-Channel Relay Multiplexer
Agilent E1451A Terminating 20 MHz Pattern I/O Module
Agilent E1441A Arbitrary Waveform Generator
Agilent E1490C VXI Breadboard Module
Agilent E1490B VXI Breadboard Module
Agilent E8305A 250 MHz Pulse Pattern Generator
Agilent E1438D 100 MSa/s Digitizer with DSP and Memory
Agilent E1420B High-Performance Universal Counter
Agilent E1406A VXI GPIB Command Module
Agilent E6234A VXI Pentium PC Controller
Agilent E1426A Digitizing Oscilloscope 500 MHz
Agilent 0950-2283 E1401B High-Power VXI Mainframe Power Supply
Applied Materials 0090-09061-A Thermal Electric Driver Module
Applied Materials 0110-09023-D Mini DI/DO Module
Applied Materials 0110-09022-B Mini AI/AO Module
Applied Materials 0100-09006-M1 Intelligence Interface Module
Applied Materials 0100-11002 Digital I/O VME Module
Applied Materials AMAT 0100-20173 Stepper Controller VME Module
Applied Materials 1043-0024-003 Digital Interface VME Module
Applied Materials 0100-01321 Digital I/O VME Module
Applied Materials 0100-20001 System Electronics Interface VME Module
Bently Nevada 200200-11-11-05 proTIM-R Module
Bently Nevada 1701/10 FieldMonitor 24-Volt dc Power Supply
Bently Nevada PWA88199-01 Rear Control Panel
Bently Nevada 78432-02 Power Input Module
Bently Nevada 78462-01 3300 Relay Module -Conformal Coated
Bently Nevada 3300/80-01-01-01 Six channel stick drop monitor
Bently Nevada 81192-03 Thermocouple Input Module
ASFC-01C 64649540 Switch fuse controller
Bently Nevada 81546-01 Dual Hermetic Relays Module
Bently Nevada 84142-01 XDUCR I/O and Record Terminals Module
Bently Nevada 86416-01 Multi-Channel Diagnositc Instrument
Bently Nevada 82925-01 XDCR I/O and Record Terminals Module
SYN 5202a-Z V221 3BHB006715R0221 SYNCHROTACT®5 is a fifth generation synchrotact device
Bently Nevada 84157-01 LVDT (POT) and Record Terminals Module
Bently Nevada 88501-01 3300 External KO Inputs and Buffered Outputs Module
Bently Nevada 76683-02 35mm 3300 Series Proximitor
Bently Nevada PWA88219-01U 3300 Power Supply
Bently Nevada 78462-02N 3300 Relay Module
Reviews
There are no reviews yet.