Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
FOXBORO RH916XG FBM201 TERMINAL ASSEMBLY
ALLEN BRADLEY 80165-698-51-R PC BOARD
RELIANCE 0-57210-31 Stabilizer plate
ABB T-1521Z Multifunctional link
ABB R-2521Z Multifunctional link
VT-HNC100-2-30/P-I-00/G02 R901134616
FOXBORO P0916QD FBM218/237 Redundant Adapter
FOXBORO P0916DE CABLE
ABB LST200 Ultrasonic level transmitter
FBM215/218 P0917XV COMPRESSION TERMINATION ASSEMBLY
DS200DCFBG1BLC GE Power Supply Board
ALLEN BRADLEY 192646 PC BOARD
ALLEN BRADLEY 185558 Driver isolation circuit board
ALLEN BRADLEY 154958 PC BOARD
Rockwell 148540 NODE ADAPTER BOARD
ALLEN BRADLEY 74102-462-53 Ac driver board
Rockwell A-B 1336S-EN6 Ac driver
A-B 1336-L5 Control interface board
TRICONEX 4000098-510 Cable assembly 10 ft
WEIDMULLER 915917/67 Terminal Adapter
146031-01 Bently Nevada Transient Data Interface I/O Module
MTL 8724-CA-PS module power supply carrier
Allen-Bradley 1756-OB16E Discrete output module
1452-25M Prosoft Connector
842E-CM-MIP3BA Encoder
Foxboro P0926JM 8 Position Modular Baseplate Stock
P0922XS Foxboro TSC Power Cable
FOXBORO RH916DD controller
AO920N 3KDE175533L9200 S900 I/O system
FOXBORO RH916XG FBM 201 TERMINAL ASSEMBLY
AO920B 3KDE175532L9200 S900 I/O System
DO930N 3BDS014114 S900 I/O system Digital Output
DO910S 3KDE175321L9100 S900 I/O system
DO910N 3KDE175323L9100 S900 I/O system
PM862K02 3BSE081636R1 AC800M PM862 controller
PM863K01 3BSE088381R1 AC800M PM863 controller
PM866AK01 3BSE076939R1 AC800M PM866/PM866A controller
PM867K02 3BSE081638R1 AC800M PM867 controller
PM864AK02 3BSE018164R1 AC800M PM864A controller
PM851AK01 3BSE066485R1 AC800M PM851/PM851A controller
PM856AK01 3BSE066490R1 AC800M PM856A controller
SA920N 3BDH000600R1 S900 I/O system
SA920B 3BDH000601R1 S900 I/O system
DX910S 3KDE175311L9100 S900 I/O system
DX910N 3KDE175313L9100 S900 I/O System
DX910B 3KDE175312L9100 S900 I/O System
DP910S 3KDE175361L9100 S900 I/O system
DP910N 3KDE175363L9100 S900 I/O system
DP910B 3KDE175362L9100 S900 I/O system
PM858K02 3BSE082896R1 AC800M PM858 controller unit
Reviews
There are no reviews yet.