Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
HE700GEN100C GE industrial control card
IC660ELB912J GE Genius Network interface module
FBM230 P0926GU FOXBORO Modbus main (serial and TCP/IP) driver
F8621A HIMA Central processing unit (CPU) module
ENT-10515-R HIRSCHMANN AC AC power module
DSAI130A 3BSE018292R1 ABB analog input module
DKC01.3-012-3-MGP-01VRS Rexroth DKC drives the controller
DIGIFAS-7202 KOLLMORGEN servo drive
DECS-200-2L BASLER ELECTRIC Digital automatic excitation regulator
CX1100-0001 BECKHOFF Power device and I/O port
CI520V1 3BSE012869R1 ABB AF100 communication interface
CC-PCNT02 HONEYWELL C300 module controller
A413654 METSO Communication module
BC25 ABB Robot card parts
A413240 METSO Printed circuit board
086329-004 ABB Control card
5466-316 WOODWARD analog input output module
1786-RPA Allen-Bradley ControlNet Modular repeater adapter
5204-DFNT-PDPMV1 PROSOFT Ethernet /IP to the PROFIBUS DPV1 main gateway
531X303MCPARG1 GE AC Power Supply board
810-017034-005 LAM VME PCBA, processor
8LSA25R0060D000-0 B&R Synchronous motor
64SD1-08KRF1-13 NAI Data multi-function board card
6SM77K-3.000 KOLLMORGEN Servo motor
6SM56-S-3000 KOLLMORGEN Servo drive
5PP320.1505-39 B&R Power panel PP320 BIOS15 “XGA color TFT display
3HAC9710-1 ABB Heat exchanger unit
YNT512D YOKOGAWA Trunk repeater
3BHB003688R0101 ABB Variable frequency circuit board
WR-D4007 RELIANCE Power supply card
VT-VSPD-1-23/V0/0-0-1 Rexroth magnifying plate
VE6041F01C1 DeltaV intelligent switch
UTLH21 TOSHIBA Industrial controller Unifi nv series controller
SM-100-40-080-P0-45-S1-B0 ELAU Servo motor
8310N2 TRICONEX 8310N2 Communication module
SC-TCMX01 51307198-175 HONEYWELL RTU2020 base
PW502 YOKOGAWA Isolated wide range power supply panel
SC-PCMX01 51307195-175 HONGEYWELL RTU2020 controller remote terminal device
PM865K01 3BSE031151R1 ABB AC800M Processor unit
PR9268/601-000 EPRO sensor
PFTL201C 3BSE007913R50 50KN ABB Pressure transducer
PCD232A101 3BHE022293R0101 ABB Controller processing unit
P4LQA HENF209736R0003 ABB Unit module
MP3010 EATON Fixed case motor protection relay
MDX61B0015-5A3-4-0T SEW Inverter drive
62K-NHC0-DH VIPA 10-inch ecological human-machine interface
MAX-4/11/03/128/99/1/1/00 Elau 24v Dc Pac Drive Control
LSH-050-2-45-320T1.1R Lust LTi Drives Servo motor