Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
3BDH000383R0005 DX722F Digital input/output module
3BDH000387R0005 DX731F Digital input/output module
3BDH000371R0005 DA701F Digital/Analog module
3BE066485R1 PM851AK01 Processor unit
3BE069449R1 CI854BK01 PROFIBUS-DP/V1 port
3BSE020512R1 AI801 Analog Input 8 channels
3BSE020514R1 AO801 Analog output 8 channels
3BSE020508R1 DI801 Digital input 24V 16 channels
3BSE020510R1 DO801 Digital output 24V 16 channels
3BSE013208R1 TB820V2 Modulebus Cluster modem
3BSE008508R1 DI810 Digital input module
3BSE020836R1 DI840 Redundant digital input module
3BSC690073R1 DI890 The digital input module is intrinsically secure
3BSE008510R1 DO810 Digital output module Transistor type
3BSE020838R1 DO840 Redundant digital output module transistor type
3BDH000530R1 PM803F Base Unit 16 MB
3BDH008381R0001 TU732F Input/output terminal device
3BSE076940R1 PM 862K01 Processor Unit -67MHz and 32MB.
3BSE092689R1 CI 867AK01 Modbus TCP interface
MU-CTVF11 HONEYWELL Vertical Trim Panel Set – Full Height
MU-CTVH11 HONEYWELL Vertical Trim Panel Set – Half Height
MU-SMAC02 HONEYWELL Analog Output Standby Manual
MU-SMDC02 HONEYWELL Digital Output Standby Manual
MU-KSX152 HONEYWELL SDISI FTA EIA – 485 Cable
MU-MASX02 HONEYWELL Manual/Auto Station
MU-MASX02 HONEYWELL Manual/Auto Station
MC-TSIA12 HONEYWELL MU-TSIA12 Serial Interface FTA for Allen-Bradley
MC-TSIM12 HONEYWELL MU-TSIM12 Serial Interface FTA for Modbus
MC-TSDU02 HONEYWELL MU-TSDU02 Serial Device Interface FTA for UDC 6000
MC-TSDM02 HONEYWELL MU-TSDM02 Serial Device Interface FTA for Manual/Auto Station
MC-TSDT02 HONEYWELL MU-TSDT02 Serial Device Interface FTA for Toledo Scale
PCI-7813R Digital reconfigurable I/O devices
MC-TDOY63 HONEYWELL MU-TDOY63 Digital Output Relay FTA (16 Outputs)
MC-TDOY62 HONEYWELL MU-TDOY62 Digital Output 24 Vdc FTA (32 Outputs)
MC-TDOR62 HONEYWELL MU-TDOR62 Digital Output 240 Vac/125 Vdc Relay FTA
MC-TDOR52 HONEYWELL MU-TDOR52 Digital Output 120 Vac/125 Vdc Relay FTA
MC-TDOD62 HONEYWELL MU-TDOD62 Digital Output 5-200 Vdc Solid State
Reviews
There are no reviews yet.