Description
PFSK151 3BSE018876R1 Контроллер ABB
Швейцария, и входит в десятку крупнейших швейцарских транснациональных корпораций.PFSK151 3BSE018876R1
химическая, нефтехимическая, фармацевтическая, целлюлозно – бумажная, нефтепереработка; Оборудование приборов: электронные приборы, телевизоры и оборудование для передачи данных,
генераторы, гидротехнические сооружения; Каналы связи: интегрированные системы, системы сбора и распространения;PFSK151 3BSE018876R1Строительная промышленность: коммерческое и промышленное строительство.
user experience
Secondly, if power system engineers are to consider the convenience and speed of using the product in the future, operability needs to be improved while ensuring stability.
This requires a simple self-service system and an operation interface with good visual effects that can meet the needs of users. Some operating habits and other aspects
* cut costs
Furthermore, since there are many nodes in the power system, the same product needs to be deployed on many nodes. Then when the quantity of required products increases,
cost issues will inevitably be involved. How to solve the research and development, construction and installation of products and better reduce operating expenses is also a major issue that ABB needs to consider.
Implementation of communication between Omron vision system and ABB industrial robot
introduction
In modern production processes, vision systems are often used to measure and identify products, and then the results are transmitted to industrial robots for work
through communications . In this process, communication settings are very important. This article analyzes the communication implementation process between the Omron
FH-L550 vision system and ABB industrial robots. The main task is to enable the vision system to provide data detection results for ABB industrial robots, and the industrial robots
perform related operations based on the data results. This article mainly discusses the entire process of visual system communication transmission implementation.
1Ethernet-based communication settings in vision software
The main communication methods of Omron FH-L550 vision system controller are as follows [2], namely: parallel communication, PLCLINK communication, Ethernet
communication, EtherCAT communication, and protocol-free communication. These five communication methods have their own characteristics in the communication process.
In modern equipment, Ethernet communication
(Ethernet communication) is the most common, so this article uses the Ethernet communication method as an example to analyze and explain.
First, select the “Tools” option in the main interface, select the “System Settings” menu (Figure 1), after entering the “System Settings” menu, click the “Startup Settings” option,
and select the “Communication Module” tab (Figure 2 ), after completing the above settings, return to the main interface to save the settings (Figure 3). Finally, select the function
menu to perform system restart settings, and wait for the system to complete the restart before proceeding to the next step.
After the system restarts, click the “System Settings” menu again and select the “Ethernet (No Protocol (UDP))” option (Figure 4). In this option, there will be parameter settings
such as IP address and port. What needs to be noted here are the two IP address parameters. The parameters in “Address Setting 2” need to be filled in. The information that needs
to be filled in includes the IP address of the vision controller, subnet mask, default gateway and DNS server.
In the port number setting of “Input/Output Settings” at the bottom of the menu, set the port number for data input with the sensor controller. Note that the port number should
be the same as the host side, and finally complete the settings and corresponding data saving work.
2ABB industrial robot communication settings
First, configure the WAN port IP address for the ABB industrial robot. Select the control panel in the teach pendant, then select configuration, then select communication in
the theme, click IPSetting, set the IP information and click “Change” to save the IP information.
Next, use the SocketCreate robot command to create a new socket using the streaming protocol TCP/IP and assign it to the corresponding variable (Figure 5). Then
use the SocketConnect command to connect the socket to the remote computer. After the communication connection is completed, it is necessary to send and receive
information from the visual system. To send information, use the SocketSend instruction to send data instructions to the remote computer. After the vision system collects
information and makes judgments, the industrial robot system will receive data from the remote computer. The data reception is completed using the
SocketReceive instruction. This instruction stores the data in the corresponding string variable while receiving the data. Useful information needs to be extracted from the
received data information, which requires StrPart to find the specified character position instruction, extract the data at the specified position from the string, and assign the
result to a new string variable. Finally, when the socket connection is not in use, use SocketCloSe to close it.
IB3111500 ELEMASTER IB3111500 Output module
IB3110551 ELEMASTER IB3110551 Output module
3110250 ELEMASTER 3110250 Output module
3110050 ELEMASTER 3110050 Output module
IB3110250 ELEMASTER IB3110250 Output module
1407-CGCM C Allen-Bradley Combination Generator Control Module
XV-442-57CQB-1-10 EATON TOUCH PANEL
MVI56-MNETR PROSOFT TCP/IP interface module
SMPCONT-A3B KOKUSAI Main control circuit board
SCXI-1162 NI 32-Channel Digital I/O Module
MVI94-GSC PROSOFT ASCII Network Interface Module
ATK4A-00 YOKOGAWA KS Cable Interface Adapter
DPM-MC2 EATON Communication module
P0916AA FOXBORO Field Terminal Assembly
8V1090.00-2 B&R Integrated line filter
PMC234 FORCE Series12-bit ADC Enhanced FPPA 8-bit Controller
SR 750-P1-G1-S1-HI-A20-G GE FEEDER MANAGEMENT RELAY
SCYC55830 58063282A ABB Programmable controller module
AB91-1 HESG437479R1 HESG437899 ABB Analog module
1C31157G02 Westinghouse Input Output
HE693ADC409A-22 GE Millivolt Analog I/O Module
A1SJ51T64 MITSUBISHI Link Remote I/O System Master Module
BTV04.2GN-FW Rexroth BTV04 Miniature Control Panels
DS3800DFXA1B1C GE analog module
2302-32-VLE-2 YOKOGAWA Industrial display screen
SCXI-1121 NI 4-Channel Universal Input Module for SCXI
SCXI-1102B NI 32-Channel Voltage Input Module
IS230SNIDH1A GE Gas Turbine Module
SCXI-1102 NI 32-Channel Thermocouple Amplifier Module
SCXI-1001 NI 12-Slot AC Chassis
IS200SDIIH1ADB GE industry gas turbine system card
PTQ-PDPMV1 PROSOFT Main station network interface module
FI840F 3BDH000033R1 ABB Fieldbus Module FF HSE
SR511 3BSE000863R1 ABB Regulator 24V/5V
MB510 3BSE002540R1 ABB Program Card Interface
CI535V30 3BSE022162R1 ABB SPA Server protocol SPA Bus
CI522A 3BSE018283R1 ABB AF100 interface
HIEE200130R0002 AFC094AE02 ABB ARCnet control panel
PR6423 EPRO extension/extended line
PR6423-003-030 EPRO Sensor and preposition
AO3481 TRICOENX Analog Output Module
3BSE017427R1 NBIO-21CU ABB ANALOG IO-UNIT
Reviews