Sale!

MC-TAMR04 Power module Honeywell

Original price was: $1,888.00.Current price is: $1,688.00.

Model:MC-TAMR04

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Product parameters
Model: MC-TAMR04
Brand: Honeywell
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
MC-TAMR04 is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
MC-TAMR04 is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: MC-TAMR04 Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install MC-TAMR04 correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating MC-TAMR04 to ensure proper use.
Product Introduction
MC-TAMR04 is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

https://www.xmamazon.com

https://www.xmamazon.com

Home

Home

https://www.plcdcs.com/

www.module-plc.com/

https://www.ymgk.com

UNS 0881a-P,V1 3BHB006338R0001 GDI Gate Driver Interface V1
3ADT220090R0006 SDCS-PIN-51-COAT Measurement Card PIN51
GVD241A101 3BHE022886R0101 GV D241 A101 PIN 6080 power connector – coated
UCD240A101 3BHE022287R0101 UC D240 A101 Communication Control
PPD539A102 3BHE039770R0102 PP D539 A102 AC 800PEC controller device
PCD235A101 3BHE032025R0101 PC D235 A Combined Input Output
3BHE022293R0101 PCD232A  Combined Input Output
AFD242A10 3BHE023126R0010 AF D242 A10 SCP Service Ctrl Panel
AFD242A20 3BHE023126R0020 AF D242 A20 CCP Convert Ctrl Panel
3BHE051993R0001 Adapter plate UAD215 to UAD209
UAD215A106 3BHE026284R0106 UA D215 A106 CSI Converter Signal Interface
UAD215A105 3BHE026284R0105 UA D215 A105 CSI Converter Signal Interface
UAD215A104 3BHE026284R0104 UA D215 A104 CSI Converter Signal Interface for UNL14300
UAD215A102 3BHE026284R0102 UA D215 A102 15V, 1000V CSI Converter Signal Interface
UAD215A101 3BHE026284R0101 UA D215 A101 Converter Signal Interface for D5 UN6800 & UNL 13300
PCD530A102 3BHE041343R0102 PC D530 A102 standard Controller Board
PCD231B 3BHE025541R0101 PC D231 B Converter Control Interface
PCD230 3BHE022291R0101 PC D230 A ABB Communication Control Measurement UNITROL 6000 X-power
UNS 0862a-P,V1 HIEE405179R0001 Analog I/O ABB
UNS3020 HIEE205010R0001 failsafe relay
DSQC431 3HAC036260-001 IRC5C Compact Controller
UNS3020 HIEE205010R0003 UNS 3020A-Z,V3 Ground Fault Relay
2711-K10G14 Touchscreen – 10″ Color Display
2711-K10G10L1 Standard Type Operator Terminals
2711-K10G1 standard operator terminal
2711-K10C9L1 Panelview interface terminal
2711-K10C9 PanelView 1000 Standard Operator Terminal
2711-K10C8L1 operator interface terminal
2711-K10C3L1 Panelview 1000 Series Operator Terminals
2711-K10C3 HMI operator panel
2711-K10C20L1 Human Machine Interface (HMI) Devices
2711-K10C20 PanelView 1000 Standard Operator Terminal
2711-K10C1L1  terminal is controlled by the keyboard
2711-K10C16L1 10″ color display
2711-K10C16 10-inch display
2711-K10C15 Standard Types of Allen-Bradley Operator Terminals
2711-K10C15L1 Numeric keypad operator interface terminal

Reviews

There are no reviews yet.

Be the first to review “MC-TAMR04 Power module Honeywell”

Your email address will not be published. Required fields are marked *