Description
hardware flow control. It is an ideal choice in the field of industrial automation.
We can perform simulation algorithms on Matlab.
3. The role of frequency converter
1. Frequency conversion energy saving
The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.
The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.
Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
TVB6002-1/IMC 1308-644857-12 1381-644857-16 TEL BOADR
TVB3101-1/ISC 1381-644957-16 1308-644957-12 TEL BOARD
TVB-1202-1/ANET 1381-647980-12 TEL board
XV-440-12TSB-1-10 EATON Touch panel
SLIO-02 ROLLS ROYCE NETWORK CONTROLLER
45C992 RELIANCE Analog Input Module
MVI69-MCM PROSOFT Modbus Master/Slave Network Interface Module
LD800HSE-3BDH000320R02 ABB Fieldbus Linking Device
KP3000 ABB Silicon controlled module
KP2500 ABB Silicon controlled module
3100-MCM PROSOFT Modbus communication interface
1785T-PMPP-1700 Rockwell touch screen
5SHY35L4503 ABB High voltage IGCT driver module
SCXI-1313A NI Terminal Block
SC753A-001-01 Pacific Scientific Servo Drive
SAC-SW220/EB ORMEC SERVOWIRE DRIVE
S22460-SRS KOLLMORGEN Servo driven drive
PXI-6713 NI PXI Analog Output Module
PXI-6602 NI Counter/Timer Module
PMC-234 RAMIX CompactFlash Module
PCIE-5565-PIORC GE Reflective Memory node card
ZETA6104 Parker Indexer/Drive
KJ1710X1-BA1 EMERSON Fibre Channel Switch
H1127.0101 Rolls-Royce Marine Controller
FSA80 DANAHER Servo drive
FAW05-5R0 TDK AC-DC Power Supplies
F7133 HIMA 4 Channel Power Distribution Module
F6217 HIMA 8-Channel Analog Input Module
F3330 HIMA 8-Channel Output Module
F3322 HIMA Digital Output Module
F3236 HIMA 16-Channel Digital Input Module
EC10-2416BRA EMERSON Frequency converter module
DSQC1018 ABB Computer
DKC11.1-040-7-FW Rexroth DKC Drive Controllers
CR-GENO-M6400R3 DALSA Teledyne Industrial Camera
CLS204 WATLOW ANAFAZE Temperature control unit
CACR-02-KIBA YASKAWA SERVO DRIVER
C2RPS-PSM ENTERASYS Power Supply
AT-MR126F ALLIED TELESIS TRANSCEIVER MICRO REPEATER
VFD_6713_V2 HONEYWELL main control panel
330103-00-06-10-02-05CN Bently Nevada 3300 XL 8 mm Proximity Probes
AT-MX40FST-05 ALLIED TELESIS International Pty Ltd
ACN CS METSO high-performance multi-function
3500/40M 140734-01 Bently Nevada Proximitor Monitor I/O Module
70085-1010-411 13A AI-TEK Speed sensor
8602-FT-ST GE PAC8000 Field terminal, standard
ZETA6104 PARKER Indexer/Drive
1C31179G01 Westinghouse Remote Input Output Master Attachment Unit
VT-HNC100-1-23W-08-P-0 Rexroth VT-HNC100 Digital Axis Controllers
VRDM 39750 LWB Berger Lahr stepper motor
VFD4A8MS21ANSAA Delta Variable frequency Drive (VFD)
VE6041F01C1 EMERSON Smart Switch
UMI-7764 NI Universal Motion Interface
TVD1.3-15-03 Rexroth TVD Supply Modules
T2550L80F32ELINSERIAL FOXBORO unit controller
Reviews