Sale!

IS420PUAAH1A GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS420PUAAH1A

Первоначальная гарантия на один год.
IS420PUAAH1A Параметры

IS420PUAAH1A Размер 30 * 20 * 30
IS420PUAAH1A Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

A413139   Network I/O processor
DSTA131 Drive data manager  controlling drives
PXIE-5105  High-density PXI oscilloscope
D201471  Digital input/output module
A413188  Multiprocessor system
IC200ALG320 Analog output module
D201376 Analog input module analog signals
XVR19 6U-VME-SBC  Single board computer
D201190 Flow control valve high performance
CTB810  HN800 Communication terminal board
FPN1903A   Switching power supply
CRIO-9073 controller   embedded system
D3000 Dual protection mechanism
SHC68-68-EPM  With redundant power input
BMXDDI3202K   Input module  into digital
BMXCPS2010  isolated power module
BMXDDO6402K  Discrete quantity output module
1794-IF4IXT  Motor control equipment
150-C85NBD   Soft starter  redundant input
HPC800底座MB810   Data collection and alarm management
A413139 Computer controller
VMIVME 3215-000   cpu module
PC834-001-T  laboratory instruments
D201471 Digital input and output module
F860-CA High quality terminal board
MDB-8E Micro electronic balance
AI02J  High precision current transmitter
FCM2F2 P0914YZ Bus extender
CRIO-9073 embedded controller
ZMI-4104 displacement measurement electronic
S30361-NA DANAHER servo controller
PW702 Power module  overvoltag
REF610C11HCNN01(含底座)  contactor
MVME55006E-0161R  High performance embedded computer
87199-01 digital signal processor
MTL4842 Surge Protective Device
85UVF1A-1QD  Solid state flame detector
EMERSON A6370D Digital expansion module
IC200PBI001  GE  Network Interface Unit
CRIO-9073  NI  CompactRIO Controller
85UVF1A-1QD Integrated Flame Scanner with Internal Relay
S30361-NA DANAHER  KOLLMORGEN  Servo driver
ZMI-4104  Displacement measurement Interferometers
PW702  YOKOGAWA  Dc power module
“ABB AI02J  A current transmitter”
Foxboro RH926GQ Distributed I/O module
FOXBORO FCM2F2 P0914YZ  Bus expander
A-B 1756-IF4FXOF2F  Analog input channel
VE4006P2 Programmable controller
136703-01  Communication module
ABB DSQC652  Standard IO signal board
EMERSON IC200PBI001 Network interface unit

Reviews

There are no reviews yet.

Be the first to review “IS420PUAAH1A GE Mark VI”

Your email address will not be published. Required fields are marked *