Sale!

IS420PPNGH1A GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS420PPNGH1A

Первоначальная гарантия на один год.
IS420PPNGH1A Параметры

IS420PPNGH1A Размер 30 * 20 * 30
IS420PPNGH1A Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

IS420PPNGH1A GE Mark VI
IS420PPNGH1A GE Mark VI
IS420PPNGH1A GE Mark VI Product details:

IS420PPNGH1A Technical Manual

IS420PPNGH1A Weight:1.8KG
IS420PPNGH1A Size: 20* 20 * 10cm
IS420PPNGH1A instructions
IS420PPNGH1A PDF
IS420PPNGH1A  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
IS420PPNGH1A  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IS420PPNGH1A :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

3.3 Design of computer control software

This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.

The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.

3.4 Design of touch screen software

The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.

3.5 Design of PLC software

As the core of this control system, PLC is mainly responsible for the following aspects:

Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.

Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.

It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.

Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface

3.6 Frequency converter settings

In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:

Switch the control mode to local control and set the inverter address according to the inverter user manual.

Set the inverter for remote control and select the communication mode.

Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.

Set the speed control mode of the inverter, such as speed control or torque control.

After completing the basic parameter settings, switch to the remote control state and wait for remote control.

4 Conclusion

This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.

ABB  3BHE041343R0102
ABB  PCD530A102
ABB  PCD530A102 3BHE041343R0102
ABB    3BSE048845R1
ABB    CI868K01
ABB    CI868K01 3BSE048845R1
ABB    3BSE043660R1
ABB    CI867K01
ABB    CI867K01 3BSE043660R1
ABB    3BSE018135R1
ABB    CI858K01
ABB    CI858K01 3BSE018135R1
ABB    3BSE018144R1
ABB CI857K01
ABB CI857K01 3BSE018144R1
ABB 3BSE026055R1
ABB CI865K01
ABB CI865K01 3BSE026055R1
ABB 3BUA000037R1
ABB CI862K01
ABB CI862K01 3BUA000037R1
ABB 3BSE026055R1
ABB CI856K01
ABB CI856K01 3BSE026055R1
ABB 3BSE018106R1
ABB  CI855K01
ABB  CI855K01 3BSE018106R1
ABB   3BSE030220R1
ABB   CI854AK01
ABB   CI854AK01 3BSE030220R1
ABB  129740-002
ABB 3BSE012869R1
ABB CI520V1
ABB CI520V1  3BSE012869R1
ABB 3BSE018283R1
ABB CI522A
ABB CI522A 3BSE018283R1
ABB 3BSE010700R1
ABB CI534V02
ABB CI534V02 3BSE010700R1
ABB 3BSE022162R1
ABB CI535V30
ABB CI535V30 3BSE022162R1
ABB 3BSE014666R1
ABB CI541V1
ABB CI541V1 3BSE014666R1
ABB 3BSE012545R1
ABB CI546
ABB CI546 3BSE012545R1
ABB 3BNP004429R1
ABB CI547
ABB CI547  3BNP004429R1
ABB 3BSE001440R1
ABB CI570
ABB CI570 3BSE001440R1
ABB CI610
ABB CI615
ABB CI626
ABB 3BSE005029R1

Reviews

There are no reviews yet.

Be the first to review “IS420PPNGH1A GE Mark VI”

Your email address will not be published. Required fields are marked *