Sale!

IS220UCSAH1A General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS220UCSAH1A

Первоначальная гарантия на один год.
IS220UCSAH1A Параметры

IS220UCSAH1A Размер 30 * 20 * 30
IS220UCSAH1A Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

DSSR122 4899001-NK  ABB  Power Supply Unit
DRIVER AZD-KD AZ Series EtherCAT Compatible Driver
CP-9200SHSVA  YOKOGAWA  Output relay
CI871K01  3BSE056767R1  ABB   Profinet IO Interface
CB06551  KOLLMORGEN  S600 servo drive
C7012E1104 HONEYWELL  Flame Sensor
BC810K01  ABB  CEX-Bus Interconnection Unit
AO2000-LS25  ABB  Integrated analyzer system
ACC-24E2A  Delta Tau  UMAC Turbo 4-Axis Analog Interface Module
3171197-4  MAN B&W  HMI Panel Module Marine Engine Controller Indicator
330709-000-050-10-02-00  Bently Nevada  3300 XL 11 mm Proximity Probes
330106-05-30-05-02-00  Bently Nevada  3300 XL 8 mm Reverse Mount Probes
5136-PFB-PCI  SST  Profibus Communications Adapter Module
3430-2 SAMSON Air operated regulator
3096-1000   APPLIED MATERIALS   radiometer
2301E 8273-1011  Woodward  Speed controller
683B-23795  MKS   throttle valve
469-P5-LO-A20-E  GE  LO Control Power with 4-20mA Analog Outputs
27E121  TE Connectivity   Relay socket and hardware
0190-24007  AMAT  Semiconductor board card
15I-2-FMO  Gecma Challenger  Remote PC Terminals
8V1090.00-2   B&R   ACOPOS servo drive
8LSA46.R0045D000-0  B&R  synchronous motor
4PP220.0571-R5  B&R Power Panel PP220 5.7″ QVGA color LC-display with touch screen
ND32-5610 ND32-5610VS-101-011-31 NOVOTRON  servo converter
D100644  METSO  Rev. 05 EFC Ethernet Coax Field Bus Converter Valmet
A404K  BASLER A404K   INDUSTRIAL CAMERA
PCD232A 3BHE022293R0101  ABB  Communication Interface
GFD233A103 3BHE022294R0103 ABB  Interface Module
GFD233A 3BHE022294R0103 ABB  Interface Module
CI871K01 3BSE056767R1 ABB  Profinet IO Interface
CAI04 ABB  CAI04
DO810 3BSE008510R1  ABB   16 digital outputs
DI04  ABB  DI module, 16-CH, 48 VDC
PM864AK01 3BSE018161R1 ABB  Processor Unit
9907-164  Woodward  505 Digital microprocessor-based Controllers
GPU/2 GS  DEIF  Generator paralleling controller
RMP201-8   KONGSBERG   DIGITAL INPUT MODULE
1785-ME64/A  Allen-Bradley  Memory Device
8200-1300  Woodward  integrated graphical front panel HMI
1756-RM/A  Allen-Bradley  ControlLogix enhanced redundancy module
1756-L63/B  Allen-Bradley  5560 ControlLogix Programmable Automation Controller (PAC)
1756-L61/B Allen-Bradley  standard ControlLogix series controller
1756-EN2T/B  Allen-Bradley  communication module