Sale!

IS220PRTDH1B GE Steam Turbine System

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS220PRTDH1B

Первоначальная гарантия на один год.
IS220PRTDH1B Параметры

IS220PRTDH1B Размер 30 * 20 * 30
IS220PRTDH1B Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

PM866K02 3BSE081637R1 ABB
PM851AK01 3BSE066485R1 ABB Processor Unit
PM864AK02 3BSE018164R1 ABB controller
3BSE018172R1 SB822 ABB battery module
DSAI130K20 3BNP004118R1 ABB analog input DSAI130
6100BZ10010B ABB module
EL3020 ABB Power supply Unit
DSBC110 57310256-E ABB module
SPHSS13 ABB Bailey Hydraulic Servo Module
UFC719AE01 3BHB003041R0101 ABB control unit
PPA322B HIEE300016R2 HIEE400235R1 ABB control unit
PMA323BE HIEE300308R1 ABB board
DSPC174 3BSE005461R1 ABB Analog input module
DSSB140 48980001-P ABB power module
PFSK160A 3BSE009514R1 ABB processor board
PFSK162 3BSE015088R1 ABB module
PFSK164 3BSE021180R1 ABB Analog I/O Modules
PFSK130 3BSE002616R1 ABB module
IC693MDL644  GE  Series 90-30 DC Voltage Input Module
IC693MDL645CA  GE  Programmable Logic Controllers
IC693MDL645  GE  Series 90-30 module
IC693MDL645LT  GE  Programmable Logic Controllers
IC693MDL646  GE  Series 90-30 Discrete Input module
IC693MDL646LT  GE  40 Volts DC rated PLC
IC693MDL646CA  GE  Series 90-30, 24 VDC Positive / Negative Logic discrete input module
IC693MDL648  GE  40 Volts DC rated PLC
IC693MDL654CA  GE  5/12 volt DC (TTL) Positive/Negative Logic Input module
IC693MDL653  GE  Series 90-30, 24 VDC Positive / Negative Logic discrete input module
IC693MDL654  GE  5/12 volt DC (TTL) Positive/Negative Logic Input module
IC693MDL654LT  GE  Series 90-30 Discrete Input module
IC693MDL655CA  GE  Series 90-30 Discrete Input module
IC693MDL655  GE  Series 90-30 Discrete Input module
IC693MDL655LT  GE  Series 90-30 Discrete Input module
IC693MDL660  GE  Series 90-30, 24 VDC Positive / Negative Logic discrete input module
IC693MDL740  GE  Series 90-30 module
IC693MDL734LT GE  12/24 positive logic DC output module
IC693MDL740CA  GE  OUTPUT MODULE
IC693MDL741  GE  12/24 positive logic DC output module
IC693MDL740LT  GE  digital I/O module
IC693MDL741CA  GE  12/24 positive logic DC output module
IC693MDL741LT  GE  digital I/O module
IC693MDL742  GE  Protection (ESCP) Output module
IC693MDL748  GE  digital I/O module
IC693MDL742LT  GE  Series 90-30, 12/24 VDC Positive logic output module
IC693CPU351  GE  Series 90-30 component
IC693MDL750  GE  digital I/O module