Sale!

IS215WEPAH2BA GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS215WEPAH2BA

Первоначальная гарантия на один год.
IS215WEPAH2BA Параметры

IS215WEPAH2BA Размер 30 * 20 * 30
IS215WEPAH2BA Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

ALSTOM N897164610L
ALSTOM N895314513L
ALSTOM N895313512X
ALSTOM N70032702L Shibata-type automatic coupler
IMASI23 16-Channel Universal Analog Input Module
ICS TRIPLEX T8403  Trusted TMR 24 Vdc Digital module
ETT-VGA-0045 10” 4 TFT color graphic touch screen
DSPC174 Processor Board 3BSE005461R1
CP310250 KOLLMORGEN server Driver
CML40.2-SP-330-NA-NNNN-NW Drive Controller
133396-01 Overspeed Detection I/O Module
125840-01 High Voltage AC Power Input Module (PIM)
UN0901DV1 HIER460279R1 ABB module
UN-0901b-P Var.1 HEIR 319360R1 Unitrol UN-0901b-P Module
UN0821B-PV2 HIER460356R2 ABB module
UN0810B-P HIER460262 Regulator Module
UN0809A-PV6 HIER454022R5 ABB Module
UN0808A-PV1 HIER449840R1 ABB Module
UN0806B-PV1 HIER460247R1 Unitrol Module
UN0804B-PV1 HIER458606R1 ABB Module
UN 2010 B-P V1 HEIR 207569 R1 Brown Boveri Module
UN 1024c-P HEIR318629R0001 rotor current limiter
UN 1006a-P V.1 HEIR448085R0001 monitoring module
UN 1001c-P Var.1 HIER 445519 R2 gated module
UN 0974C-P VAR.1 Unitrol UN 0974C-P module
UN 0950a-P HEIR 445976 R0001 Frequency matching module
UN 0940a-P HEIR444414R0001 Angle measurement sensor module
UN 0941c-P HIER 449641 R0001 Command generates the module
UN 0911b-P HEIR448648R0001 Voltage matching module
UN 0910a-P Var.1 HEIR444516R0001 voltage monitoring module
UN 0908a-P HEIR319306R0001 Operation Mode Selection module
UN 0906b-P HIER448845R0001 Circuit breaker Time selection module
UN 0905b-P HEIR 449705 R1 Output Stage Module
UN 0902B-P VAR.1 HIER449811 Unitrol UN 0902B-P module
UN 0901C-P Var.1 HIER456040R0001 Unitrol UN0901C-P module
UN 0900B-P Var.1 HEIR319360R1, UN 0900b-P V1 DC/DC Power module
UN 0841B-P VAR.1 HIER460394 Unitrol UN 0841B-P module
UN 0841A-P Var.1 HIER 449177 R1 Unitrol UN0841A-P module
UN 0824A-P Var.1 Unitrol UN0824A-P module
UN 0821A-P Var.1 Unitrol UN0821A-P module
UN 0820B-P VAR.1 HIER 460385 Unitrol UN 0820B-P module
UN 0820A-P Var.1 HIER 448925 R1 Unitrol UN0820A-P module
UN 0810A-P Var.2 HIER 448740 R2 Unitrol UN0810A-P module
UN 0807C-P Var.1 HIER 460271 R1 UNITROL
UN 0807B-P Var.1 Unitrol  module
UN 0802A-P Var.1 HIER 452076 R1 UNITROL
UN 0803A-P VAR.1 HIER 449240 UNITROL ABB
UN 0801A-P Var.1 HIER 448503 R1 module ABB UNITROL
UN 0800A-P VAR.1 HEIR448194 ABB UNITROL excitation
UN 0720a-P Var.1 HIER443950PI ABB UNITROL module

Reviews