Sale!

IS215UCVEH2AB GE Steam Turbine System

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS215UCVEH2AB

Первоначальная гарантия на один год.
IS215UCVEH2AB Параметры

IS215UCVEH2AB Размер 30 * 20 * 30
IS215UCVEH2AB Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

3.2 Upgrading of regulators and control systems

For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.

For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).

For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.

For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.

3.3Unitrol6800 functional logic configuration points

The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.

4 Problems discovered during the transformation and their solutions

After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.

During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.

5 Conclusion

Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.

IC800SSI107RD2-CE GE  controller
IC800SSI104P2-CE GE  controller
IC800SSI104D2-CE GE  controller
IC695GCG001 GE   Communication gateway
IC695ETM001 GE  Single slot module
IC695EDS001  GE  External station module
IC695CRU320 GE Redundant processor
IC695CPU320 GE  The central processing unit
IC695CPU315 GE  Central processing unit
IC695CPU310 GE  Programmable automation controller
IC695CPK400 GE  Programmable automation controller
IC695CPE400 GE  Central processing unit (CPU) module
IC695CPE330 GE  Automation controller
IC695CPE310 GE  Central processor module
IC695CPE305 GE  Central processing unit
IC695CPE302 GE  controller
IC693DSM302 GE  Motion controller
IC693DNS201 GE  Communication module
IC693DNM200 GE  Main control module
IC693CPU374 GE  Programmable Logic Controller (PLC) module
IC693CPU372  GE Ethernet communication module
IC693CPU370 GE Programmable logic controller
IC693CPU367 GE   Central processing unit
IC693CPU366 GE  Network CPU main module
IC693CPU364 GE  Single slot central processing unit
IC693CPU363 GE  Programmable logic controller
IC693CPU360  GE  The CPU module is embedded in the backplane
IC693CPU352 GE  Single slot CPU module manufactured by PLC system
IC693CPU351 GE  CPU module
IC693CPU350 GE  controller
IC693CPU341 GE  Single-slot CPU
IC693CPU340  GE Expansion base plate
IC693CPU331 GE The CPU module is embedded in the backplane
IC693CPU323 GE Base Turbo CPU in slot 10
IC693CPU321 GE  10-slot I/O backboard with embedded CPU
IC693CPU313 GE  Embedded CPU
IC693CPU311 GE  5 Slot Embedded CPU base rack
DSSR-122 ABB Power supply unit
DSQC664 ABB  Ac servo driver
DSQC661 ABB controller
DSQC604 ABB  Digital I/O board
DSQC545 ABB  Optical fiber point sensor
DSQC539 ABB DCS control system
DSMB-01C ABB Power strip
DSDX452  Remote input ABB
DSDI-110AV1-3BSE018295R1 ABB Digital input pad
DSDI110A-57160001-AAA ABB Digital input sets up the robot
DSCS140-57520001-EV ABB Processor
DSCL110A-57310001-KY module
DS3820PSCB GE  Turbine control module

Reviews

There are no reviews yet.

Be the first to review “IS215UCVEH2AB GE Steam Turbine System”

Your email address will not be published. Required fields are marked *