Sale!

IS215GFOIH1A General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS215GFOIH1A

Первоначальная гарантия на один год.
IS215GFOIH1A Параметры

IS215GFOIH1A Размер 30 * 20 * 30
IS215GFOIH1A Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

IS215GFOIH1A General Electric Processor Board Mark VI
IS215GFOIH1A General Electric Processor Board Mark VI
IS215GFOIH1A General Electric Processor Board Mark VI Product details:

IS215GFOIH1A Technical Manual

IS215GFOIH1A Weight:1.8KG
IS215GFOIH1A Size: 20* 20 * 10cm
IS215GFOIH1A instructions
IS215GFOIH1A PDF
IS215GFOIH1A  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
IS215GFOIH1A  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IS215GFOIH1A :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

Guoxin Yangdian ABB excitation regulator technology upgrade
1 Overview

The 2×630Mw coal-fired units (units #3 and #4) of Jiangsu Guoxin Yangzhou Power Generation Co., Ltd. were put into commercial
operation in September 2006 and January 2007 respectively. The generator excitation system is a complete set of excitation
system equipment imported from Switzerland provided by Shanghai ABB Engineering Co., Ltd. The supporting excitation system is
ABBUnitrol5000
. For more than 10 years of operation, jumper Hall elements have been disturbed and tripped, and ARCnet communication
faults have tripped. and other problems, and as the use time increases, the failure rate increases significantly,
and the stability of the excitation system gradually
decreases. According to the needs of unit capacity increase, efficiency improvement and upgrading, the company has
simultaneously upgraded the excitation system, upgraded the original Unitrol5000 to the latest Unitrol6800 system, and also
adjusted the original components
such as resistance-capacitance absorbers and jumpers. Make sure the parameters match.

2 Advantages of the modified excitation system

2.1 The reliability of the three-channel input power supply redundancy mode in the control part is improved

The power supply of the control part adopts three input power supplies with AC or DC redundancy mode, thus
improving the reliability of the system. Each control module is equipped with two independent power supplies for power supply,
which significantly improves the redundancy of the power supply. In this way, the power supply of the control module can be disconnected separately to
facilitate online replacement of faulty components. Secondly, since the boards are installed independently and each board is
powered by dual power supplies, the power supply has an independent switch, making online maintenance work safer.

2.2 Fiber optic redundant internal communications

Unitrol6800 uses optical fiber redundancy for internal communication, which avoids the problem of downtime caused by
ARCnet serial communication in the Unitrol5000 system. The controller can independently transmit the trigger pulse of the
thyristor to the rectifier bridge. In conjunction with optical fiber transmission, the trigger pulse can be generated in each rectifier bridge, making the
internal communication more resistant to interference.

2.3 Eliminate the security risks brought by the public PSl board in the original system to the system

Unitrol6800 uses a rectifier cabinet to separately collect the synchronization voltage, excitation voltage and excitation current,
which reduces the safety hazards caused by the public PsI board. In the rectifier bridge of Unitrol6800, the AC side phase sequence
detection function is added. The fan power supply uses the independent power distribution method of each rectifier cabinet. The fan power supply
loop control system of all rectifier cabinets is inside the rectifier cabinet, ensuring that each rectifier cabinet is It can independently
control the fan in the cabinet, thereby solving the problem of power loss in the fan circuit of Unitrol5000 due to relay failure and avoiding non-stop
accidents.

In the rectifier bridge of the Unitrol5000 system, a Hall element is installed on the rectifier side to measure the excitation current
of the rectifier bridge. The current sharing of the excitation current by the system must be carried out through a current sharing test.
However, the characteristics of the Hall element itself prevent it from being based on the load. changes in dynamic current sharing. To this end,
in the Unitrol6800 system, a CT is installed on the AC incoming line side of the rectifier cabinet to sample and calculate the
excitation current. The linearity of the CT is very high, which ensures that the excitation system can perform dynamic current sharing according to the
load changes of the working conditions, allowing Each rectifier cabinet of the system can be more balanced.

In the rotor overvoltage protection of the Unitrol6800 system, a current relay is used to detect the current. Since the anti-interference
ability of the current relay is stronger than the Hall element of the Unitrol5000, it can avoid false alarms of the rotor
overvoltage in the excitation system caused by external interference and avoid power generation. The occurrence of unit non-stop accidents.

3 Renovation Plan

The steam turbine generator unit has been modified to increase capacity and improve efficiency. The rated output of the steam
turbine unit has been increased from 630Mw to 650Mw, the self-set rated current of the generator has been increased from
17495A to 19245A, and the rated voltage of the excitation rotor
has also been increased from 400.1V to 428V. The excitation current increases from 4387.4A to 4697A. In this transformation
, the cabinet structure of the excitation system remains unchanged. The system upgrade is achieved by upgrading boards, updating equipment and
upgrading the control system. During the transformation process, it is necessary to ensure that the generator capacity is
increased, and the excitation system needs to provide more excitation current and voltage to ensure the stable operation of the unit by increasing the
deexcitation capacity.

3.1 Adjustment of demagnetization and AC side voltage absorption module

Since the generator is upgraded from 630Mw to 650Mw, the demagnetization and AC side overvoltage
absorption modules need to be adjusted. For the adjustment of the capacity of the excitation de-excitation
resistor, the capacity calculation of the de-excitation resistor needs to be calculated based on the most serious
de-excitation state of the generator. The demagnetizing resistor is a siC nonlinear resistor
. The number of resistors is changed from 5 to 6. The capacity of the demagnetizing resistor is 6MJ, which
meets the needs of the excitation system for demagnetizing. In the modification of the demagnetization circuit
jumper, the voltage resistance level of the thyristor was improved by replacing the jumper and BoD board. Regarding
the transformation of the overvoltage absorption module on the AC side of the rectifier bridge, according to the design
of the rectifier bridge of the ABB excitation system, the overvoltage absorption modules on the AC side of the rectifier bridge were changed to five groups in parallel.

0880001-01 Touch screen | xiongba supply Chain
086339-001 004707001474 | XIONGBA supplier
97590-8-BD-PCI4PORT | xiongba supply Chain
5466-409 70653-70070653-095 | XIONGBA Industries
Triconex 3625 Digital 24VDC Output Module | xiongba supply Chain
1756-CNBR Interface module | XIONGBA Industries
1756-CNB Interface module of the network | xiongba supply Chain
1747-L552 SLC 5/05 Controller | XIONGBA Industries
1715-OB8DE Output Module | xiongba supply Chain
216EA61b HESG324015R1 KHESG324258R3I HESG448230R1 | XIONGBA Industries
216DB61 HESG324063R0100 HESG216882A  | xiongba supply Chain
216AB61 HESG324013R0100 HESG435572P1 Binary Output | XIONGBA supplier
140CPU67260 Schneider | xiongba supply Chain
83SR06B-E GJR2395400R1210 Input/output module| XIONGBA supplier
81EU01E-E GJR2391500R1210 GJR2391511R42 Circuit board
1C31219G01 Relay Output Module | New original
1C31179G02 MASTER UNIT | Dominate industry
VMIVME-3120 ADC board VMIVME-3120-100
VMIVME-7700 Low voltage Celeron processor VMIVME-7700-010
VMIVME-4942 Rotary digital converter board VMIVME-4942-030
VMIVME-3116 High resolution analog-to-digital converter (ADC) board VMIVME-3116000
VMIVME-2210 64 channel instantaneous relay board VMIVME-2210-100
VMIVME-7751 VME single-board computer VMIVME-7751-760140
VMIVME-7588 VMEbus module VmiVME-7588-977
VMIVME-3418 Signal conditioning VME board VmiVME-3418-202
VMIVME-4941 Four channel autolitizer/Rotary digital converter board VMIVME-4941-024
UFC784AE101 Control Panel Module UF C784 AE101
UFC912A101 Circuit Board module UFC 912 A101
UFC911B104 Circuit Board Module UFC 911 B104
UFC784AE101 Control Panel Module UF C784 AE101
UFC718AE01 HIEE300936R0001 Control Board Module UFC 718 AE101
UFC762AE 3BHE006412R0001 Circuit Board Module UFC762AE
1X00163H01 I/O power supply
1X00024H01 POWER SUPPLY
1D54582G05 DPU P/S Assy 115v
1D54582G02 DPU P/S Dual Channel Assy
1D54561G02 Line interface module
1C31238H01 DI 48V DC On-Board P-Mod switch input feature module
1C31233G04 Ovation Interface module DI
1C31233G01 soe Card (24Vdc or single terminal voltage 48Vdc)
1C31232G03 Switch quantity input electronic module Ovation
1C31224G01 Analog input electronic module
1C31227G01 Analog input feature module
1C31223G01 DO PMOD Relay output module G2R
1C31222G01 DO PMOD Relay Output Base – High power
1C31197G01 Valve Position Controller
1C31194G01 Valve Position Controller
1C31169G02 LC PMOD Serial Link Controller 485 cable
1C31166G01 Serial Link Controller
1C31147G01 Pulse accumulator

Reviews

There are no reviews yet.

Be the first to review “IS215GFOIH1A General Electric Processor Board Mark VI”

Your email address will not be published. Required fields are marked *