Sale!

IS200TREGH1BDC General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200TREGH1BDC

Первоначальная гарантия на один год.
IS200TREGH1BDC Параметры

IS200TREGH1BDC Размер 30 * 20 * 30
IS200TREGH1BDC Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

IS200TREGH1BDC General Electric Processor Board Mark VI
IS200TREGH1BDC General Electric Processor Board Mark VI
IS200TREGH1BDC General Electric Processor Board Mark VI Product details:

IS200TREGH1BDC Technical Manual

IS200TREGH1BDC Weight:1.8KG
IS200TREGH1BDC Size: 20* 20 * 10cm
IS200TREGH1BDC instructions
IS200TREGH1BDC PDF
IS200TREGH1BDC  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
IS200TREGH1BDC  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IS200TREGH1BDC :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

PR6423/010-140+CON021 EPRO Diode module
Excitation power distributor MIFIIPI55E10HI00
MIFIIPI55E10HI00 GE Power supply controller
MIFIIPI55E10HI00 Signal processing board
3500/22M Robot control system
3500/22M 138607-01 Output module
3500/22M 138607-01 Control system module
106M1081-01 BENTLY 3500/15 fittings
106M1081-01 BENTLY Controller module
CP800 ABB Processor module brand new original
CP800 ABB Processor module
3BSE013177R1 ABB  MCM800 series
LDGRB-01 ABB Decentralized control
LDGRB-01 3BSE013177R1 ABB Processor module
58052582G ABB PLC module card
SCYC51020 Excitation system control panel
SCYC51020 58052582G ABB High voltage frequency converter
3BSE042240R3 ABB Programming configuration
PP825A ABB Hardware table of automatic control system
PP825A 3BSE042240R3 ABB Touch screen device
IS420ESWBH3A Robot main board
IS420ESWBH3A Ethernet module
IS420ESWBH3A GE Analog input output
A6220 Pulse amplifier board
A6220 High voltage appliance
A6220 EMERSON Redundant power modules
A6824 Communication interface
EMERSON A6824 Main control panel
A6824  AVR control unit
Frequency converter signal sampling sample A6410
A6410 Synchronize voltage detection board
A6410 EMERSON  Channel analog input module
A6110 Displacement sensor
A6110 EMERSON Analog input board
A6110 Signal receiving board
A6210 Residual pressure controller
A6210 Linear displacement sensor
A6210 EMERSON Controller master unit
Signal receiving board A6120
A6120 EMERSON Transformers and sensors
A6120 Safety control unit
9907-1200 electrohydraulic pressure-regulating valve control
9907-1200  Isolated analog signal input modules
9907-1200 WOODWARD Multi-function controller
ACC-5595-208 Robot axis calculation board
ACC-5595-208 350-805595-208N GE Servo servo module