Sale!

IS200TREGH1BDB Boards & Turbine Control Module

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200TREGH1BDB

Первоначальная гарантия на один год.
IS200TREGH1BDB Параметры

IS200TREGH1BDB Размер 30 * 20 * 30
IS200TREGH1BDB Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

3.3 Design of computer control software

This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.

The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.

3.4 Design of touch screen software

The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.

3.5 Design of PLC software

As the core of this control system, PLC is mainly responsible for the following aspects:

Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.

Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.

It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.

Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface

3.6 Frequency converter settings

In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:

Switch the control mode to local control and set the inverter address according to the inverter user manual.

Set the inverter for remote control and select the communication mode.

Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.

Set the speed control mode of the inverter, such as speed control or torque control.

After completing the basic parameter settings, switch to the remote control state and wait for remote control.

4 Conclusion

This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.

RELIANCE 805427-1S Resistance scaling module
RELIANCE 805405-5R Field power module
RELIANCE 805405-3R SF3000 Single-Phase Field Power Module
RELIANCE 805405-1R Power Module
RELIANCE 805403-3R  field power module
RELIANCE 805403-2R Resistor Scaling Module
RELIANCE 805403-1R Resistor Scaling Module
RELIANCE 805402-R Automax Distributed Power System
RELIANCE 805401-S 3-Slot PMI Rack assembly
LAM Research 605-109114-004 GE V7668A-132L00W04 4-Port Gigabit Ethernet Card Module
RELIANCE 805401-7R 4-Slot Parallel Gate Amplifier Rack
RELIANCE 805401-3S AutoMax Distribution Power System
RELIANCE 805401-2S Power Module
RELIANCE 804100-RX Remote I/O Head module
RELIANCE 804100-RV complete module
RELIANCE 61C613 analog input module
RELIANCE 61C605 8-Channel Isolated Thermocouple Module
RELIANCE 61C544  RTD module
RELIANCE 61C542 16 Channel Input Module
RELIANCE 61C516 AC/DC Input Module
LAM Research 605-048878-001 GE FANUC VME-7671-421000 SBC Board
RELIANCE 61C540 16-Point Input Module
RELIANCE 61C515 16-Bit Input Module
RELIANCE 61C501 Input Module
RELIANCE 61C500 module
RELIANCE 61C366 Analog Output Module
RELIANCE 61C351Input module simulates track card
RELIANCE 61C365 Output Module
RELIANCE 61C351 Input Module Analog Rail Card
RELIANCE 61C350  I/O Module
RELIANCE 61C345 Analog Input Module
RELIANCE 61C346  Analog Rail created
RELIANCE 61C326 PLC interface module
RELIANCE 61C23 AutoMax Local I/O headers created by the DCS system
RELIANCE 61C22 Local I/O Head made
RELIANCE 58820 AutoMax DCS system designed by MBCN
RELIANCE 57C570 AutoMax PC3000 Processor
RELIANCE 57C565 Optional string andante
RELIANCE 57C560  PC3000 processor
RELIANCE 57C554 Remote I/O Shark Interface Module
RELIANCE 57C494 Power Supply Module
RELIANCE 57C493 Automax Power Supply
RELIANCE 57C491 Supply module
RELIANCE 57C463 Frequency Event Counter Module
RELIANCE 57C446 PLC Module
RELIANCE 57C445 PC link interface
RELIANCE 57C443 Remote I/O scanning module
RELIANCE 57C442 Interface Module
RELIANCE 57C441 created Modbus Plus Module
RELIANCE 57C440 Ethernet Communication Module
RELIANCE 57C439 7010 Automax processor
RELIANCE 57C435A AutoMax Processor Module
RELIANCE 57C435 7010 Processor Module
RELIANCE Processor Module 57C431

Reviews

There are no reviews yet.

Be the first to review “IS200TREGH1BDB Boards & Turbine Control Module”

Your email address will not be published. Required fields are marked *