Sale!

IS200REBFH1BBA GE Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200REBFH1BBA

Первоначальная гарантия на один год.
IS200REBFH1BBA Параметры

IS200REBFH1BBA Размер 30 * 20 * 30
IS200REBFH1BBA Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

IS200REBFH1BBA GE Mark VI
IS200REBFH1BBA GE Mark VI
IS200REBFH1BBA GE Mark VI Product details:

IS200REBFH1BBA Technical Manual

IS200REBFH1BBA Weight:1.8KG
IS200REBFH1BBA Size: 20* 20 * 10cm
IS200REBFH1BBA instructions
IS200REBFH1BBA PDF
IS200REBFH1BBA  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
IS200REBFH1BBA  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IS200REBFH1BBA :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

We can perform simulation algorithms on Matlab.
3. The role of frequency converter

1. Frequency conversion energy saving

The energy saving of frequency converters is mainly reflected in the application of fans and water pumps. In order to ensure the reliability of production, various
production machines have a certain margin when they are designed to be equipped with power drives. When the motor cannot operate at full load, in addition to
meeting the power drive requirements, the excess torque increases the consumption of active power, resulting in a waste of electrical energy. The traditional speed
adjustment method for fans, pumps and other equipment is to adjust the air supply volume and water supply volume by adjusting the opening of the baffles and valves
at the inlet or outlet. The input power is large, and a large amount of energy is consumed in the interception process of the baffles and valves. middle. When using variable
frequency speed regulation, if the flow requirement is reduced, the requirement can be met by reducing the speed of the pump or fan.

The purpose of using a frequency converter for a motor is to regulate speed and reduce starting current. In order to produce variable voltage and frequency, the device first converts
the alternating current from the power supply into direct current (DC), a process called rectification. The scientific term for a device that converts direct current (DC) into alternating
current (AC) is “inverter”. Generally, an inverter converts DC power into an inverter power supply with a certain fixed frequency and voltage. The inverter with adjustable frequency and
adjustable voltage is called a frequency converter. The waveform output by the frequency converter is a simulated sine wave, which is mainly used for speed regulation of three-phase
asynchronous motors, also called a variable frequency speed regulator. For variable frequency inverters that are mainly used in instrumentation and testing equipment and
have higher waveform requirements, the waveforms need to be sorted and can output standard sine waves, which are called variable frequency power supplies. Generally, the price
of variable frequency power supply is 15-20 times that of the inverter. Since the main device in the inverter equipment that produces changing voltage or frequency is called “inverter”,
the product itself is named “inverter”, that is: inverter.

Frequency conversion does not save power everywhere, and there are many occasions where using frequency conversion does not necessarily save power. As an electronic circuit,
the frequency converter itself also consumes power (about 3-5% of the rated power). A 1.5-horsepower air conditioner consumes 20-30W of electricity, which is equivalent to a
continuous light. It is a fact that the inverter runs at power frequency and has a power-saving function. But his prerequisite is:

GCD207B101 3BHE024642R0101   ABB  Processor module
GDD360C 3BHE047217R0101  ABB  Processor module
F7123  HIMA  4 Channel Power Distribution Module
DO880-1 3BSE028588R1  ABB 16 channel 24 V digital output module
DMV2400A-CPCI  Data acquisition card module
ECU01 ECU01.5  EMG  control panel
PMC422FP  Ramix  Eight Port Serial Controller
CPCI-680 FORCE PowerCore CompactPCI CPU Module
0504994880 ABB  SIB V Option Board
2880065-01 PRO-FACE MST Touch screen panel
05701-A-0511  HONEYWELL  Frame module
05701-A-0361 HONEYWELL Engineering Card
5X00063G01  Westinghouse  COMPANION TO HART ANALOG OUTPUT IO MODULES
05701-A-0351  HONEYWELL  Control Card, Single Channel
05701-A-0325  HONEYWELL  DC Input Card
05701-A-0326 HONEYWELL FIELD INTERFACE CARD
5SHX1960L0004 ABB IGCT  Module
SST-PFB3-VME-2-E  SST  Network Interface Card
TSXSCP114  Schneider Electric  PCMCIA Card for Type III
MS-NAE5510-1  Johnson  Network Engine
FBM211 P0914TN  FOXBORO Input Interface Module
05701-A-0301  HONEYWELL  Single Channel Control Card 4 – 20mA
ETT-VGA-0045 UNIOP HMI Touch Screen Front Overla
CP461-50  Yokogawa  Processor Module
12149  ASSY display panel
11994R13  ASSY   Communition Module
11993R2  ASSY  Analog control card
136188-02  Bently Nevada ETHERNET/RS232 MODBUS I/O MODULE
140XCP51000  Schneider  DUMMY MODULE WITH COVER
140XBP00400   Schneider  4-Slot Backplane
140CPU11302  Schneider PROCESSOR 256K RAM 8K USER LOGIC 1XMB
MPC4 200-510-076-114  Vibro  Meter  Machinery Protection Card meggit
IOCN 200-566-000-112  Meggitt Vibro Meter
7264  AMCI  SSI Interface Module
AIP830-111  YOKOGAWA  Operating keyboard
REF601 CE446BB1NH ABB Feeder protection
3500/60 163179-01 Bently Nevada Temperature Monitors
IC660BBA104 6231BP10910  GE Analog I/O Block
135473-01  Bently Nevada Proximitor/Seismic Monitor Module
136711-01 Bently Nevada  I/O Module With Internal Barriers And Internal Terminations
FEM100 P0973CA  FOXBORO Fieldbus Expansion Module
3500-25 149369-01 Bently Nevada Enhanced Keyphasor Module
3500-05-01-02-00-00-01 Bently Nevada 3500/05 System Rack
PDP403 METSO  DISTRIBUTED PROCESSING UNIT
PDP401 METSO  Distributed Processing Unit Module Card

Reviews

There are no reviews yet.

Be the first to review “IS200REBFH1BBA GE Mark VI”

Your email address will not be published. Required fields are marked *