Description

Practical application of ABB industrial information control system 800xA in main shaft hoist control
introduction

The mine hoist is an important transportation equipment for mining enterprises. Its main function is to transport the ore,
personnel or equipment that need to be transported to the destination by the lifting container. Therefore, it plays a very
important role in the mining production process. Usually the mine hoist control system consists of a driving part and a
control part. The working mechanism
of the driving part is: the motor unit drives the mechanical hoisting device, and the frequency converter or other types
of hoisting control systems drive the motor unit: the working mechanism of the control part is: Each component of the
hoist is coordinated and controlled by the
Distributed Control System (DCS). In addition to completing basic process control, it can also integrate intelligent instruments,
intelligent transmission and motor control, and even production management and safety systems into one operation and engineering environment
middle. Therefore, the mine hoist requires a control system with high performance, high reliability, and high integration.

1ABB800xA system and AC800M controller introduction

1.1ABB800xA system introduction

The 800xA system is an industrial information control system launched by ABB. The core of its architecture is
object-oriented (ObjectOriented) technology. Due to the adoption of ABB”s unique Aspect0object concept,
enterprise-level information access, object navigation and access can become standardized and simple.

In order to provide a unified information platform for enterprise managers and technical personnel, the 800xA system
provides a base platform (BasePlatform), which relatively separates the process control part and production control
management and organically combines them together. As shown in Figure 1, the middle part is the basic platform, the upper part is the production control
management part, and the lower part is the process control part. The basic platform provides standard interfaces for
these two parts for data exchange.
1.2 Introduction to ABBAC800M controller and its programming configuration tools

AC800M controller is ABB”s latest controller series, which includes a series of processors from PM851 to PM865.
The AC800M controller itself has a pair of redundant TCP/IP interfaces. It can use the MMs protocol to communicate
with other control devices and 800xA operator stations through Ethernet. It can also use the Modbus protocol and
Point-Point protocol through 2 serial ports. communication. The programming and configuration tool of AC800M is
ControlBuilderM,
referred to as CBM. It supports standard ladder diagram, function block language, text description
language and assembly language to write control logic.

2. Improve the design and implementation of control system functions

2.1 Implementation of elevator operating speed curve

One of the main tasks of the lifting control system is to control the lifting motor to operate according to the speed-position
curve given by the design, so that the lifting container passes through the acceleration section, the uniform speed
section and the deceleration section successively, and stops accurately after completing the specified lifting distance
. somewhere in the wellbore. In order to realize the function of precise position calculation, the designed
elevator control system must be able to perform high-precision position calculation based on the photoelectric encoder
connected to the main shaft of the elevator drum. The
calculation formula is as follows:
In the formula, s is the actual position value of the elevator: sp is the distance corresponding to two consecutive encoder
pulses: AN is the difference between the encoder count value at the reference position and the current position (signed variable):
s0 is the reference position value.

The encoder counts are distributed according to the circumference of the drum. After the number of pulses Np generated
by the encoder rotation is known, the diameter of the circumference of the centerline of the wire rope wrapped around the
drum must be accurately known, so that it can be calculated according to formula (2) The distance sp corresponding to the two encoder pulses:
In the formula, D is the circumferential diameter of the centerline of the wire rope: Np is the number of pulses for one revolution of the known encoder.

But in formula (2), there is a value D that keeps getting smaller as the system runs. This is because the wire rope
used in the elevator is wrapped around the drum, and there is a lining between the wire rope and the drum that increases
friction. This liner will become thinner and thinner as the system continues to wear and tear, causing the diameter of the
circle formed by the center line of
the steel wire rope to gradually become smaller. When the pad wears to a certain extent, it will cause a large position
calculation error. In order to solve the above problems, the two parking position switches in the shaft are used to correct the drum diameter, because the
distance between the two parking positions can be obtained through actual measurement with high accuracy. During the
actual operation, record the encoder count values ​​at the two parking positions respectively. According to formula (3),
the actual correction value of sp can be calculated:
In the formula, sd is the distance between two parking positions: Abs is the absolute value operation: N is the
encoder count value when there are two parking positions.

In this way, the initial sp value is first set according to the given design parameter value, and then the value is
corrected according to the actual operating conditions, which can effectively ensure the accuracy of position
calculation. At the same time, sp” can also be substituted into formula (2), and the D value can be obtained in turn,
which can be used as a basis for judging whether the liner is seriously worn.

After obtaining the elevator position value, the speed control curve can be calculated according to formula (4):

Phoenix PATG1/23 1013847 Conductor marker carrier
Vibro-meter 200-560-000-113 200-560-101-017 VM600 IOC4T
IGCT 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 ABB
444-680-000-511 Vibro-Meter CE 680 M511 all-purpose vibration sensor
PFEA111-65/3BSE050090R65 ABB Tension Electronics PFEA 111
TRICON 4201 RXM Communication Module (Remote)
ENTERASYS A2H254-16 P0973BK Industrial switch
810-068158-013 LAM Print edition
TRICON 9001NJ(6FEET) FOXBORO Rack connection wire
125840-01 Half-Height Module 3500/15
TRICONEX 8105N Empty channel module panel
200-510-070-113 200-510-111-034 VM600 MPC4
130944-01 BLANK MODULE 3055/05
JOHNSON MS-NAE4510-2 controls MS-NAE5510-3 MS-NAE5510-1
VMIVME-7610-734 VME Single Board Computer
125680-01 Proximitor I/O Module Bently Nevada 3500/40M
125388-01 Half-height Module Bently Nevada
170AAO92100 Analog output module
SCHNEIDER VX5G48C32Q Power drive board
E82ZAFCC010 LENZE CAN INTERFACE MODULE
PNI800 Plant Network Interface Module
3500/05-01-02-00-00-01 System Rack 3500/05
IS215VCMIH2BB IS200VCMIH2BCC
FX3G-40MT/ESS Mitsubishi PLC main unit
PXIE-8115 NI PXI controller
PXIE-1065 NI PXIE case PXIE-6556
PIO800K02 ABB Profibus I/O Interface Kit [Redundant]
PNI800 Plant Network Interface Module
AI04 ABB AI module, 16-CH, TC / mV AI03
AI03 ABB AI module AI04
9907-014 Load distribution and speed control
IC755CSS15CDA Operator interface terminal
2711-T5A2L1 PanelView 550 Standard Operator terminal
VMIVME2540-000 intelligent digital input/output board
IC755SUE10CTD Touch screen GE
A06B-6110-H030 servo power converter
MDX61B0075-5A3-4-0T SEW drive
DS200LDCCH1AMA driver controls LAN(local Area Network) communication board
Pxi-8431/8 PXI Serial interface module
PXIE-6368 Multifunctional input/output module
Pxi-6528 PXI Digital input/output module
1769-L18ER-BB1B Programmable Automation controller
VMIVME-7751 VME single-board computer VMIVME-7750
1794-IRT8XT thermocouple RTD millivolt input module
PCI-1424 digital camera image acquisition board
IC220PBI002 Versapoint communication module
A06B-6079-H105 servo module
A06B-6117-H105 servo amplifier
A02B-0319-B500 Control basic unit
1326AS-B460F-21 servo motor
A06B-6140-H011 servo power converter
DSQC652 3HAC025917-001 Robot controller
DSQC604 3HAC12928-1 Power module

Reviews

There are no reviews yet.

Be the first to review “IS200EGPAG1BEC General Electric Processor Board Mark VI”

Your email address will not be published. Required fields are marked *