Sale!

IS200DTURH1ACC Reliable Turbine Control Solutions

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200DTURH1ACC

Первоначальная гарантия на один год.
IS200DTURH1ACC Параметры

IS200DTURH1ACC Размер 30 * 20 * 30
IS200DTURH1ACC Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

IS200DTURH1ACC Reliable Turbine Control Solutions
IS200DTURH1ACC Reliable Turbine Control Solutions
IS200DTURH1ACC Reliable Turbine Control Solutions Product details:

IS200DTURH1ACC Technical Manual

IS200DTURH1ACC Weight:1.8KG
IS200DTURH1ACC Size: 20* 20 * 10cm
IS200DTURH1ACC instructions
IS200DTURH1ACC PDF
IS200DTURH1ACC  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
IS200DTURH1ACC  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IS200DTURH1ACC :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

3.3 Design of computer control software

This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.

The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.

3.4 Design of touch screen software

The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.

3.5 Design of PLC software

As the core of this control system, PLC is mainly responsible for the following aspects:

Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.

Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.

It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.

Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface

3.6 Frequency converter settings

In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:

Switch the control mode to local control and set the inverter address according to the inverter user manual.

Set the inverter for remote control and select the communication mode.

Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.

Set the speed control mode of the inverter, such as speed control or torque control.

After completing the basic parameter settings, switch to the remote control state and wait for remote control.

4 Conclusion

This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.

BK9050.  Compact bus coupler
BIO0003 Capacitor bank protection
BG02.510 Repeater panel control module
BDD110-HNLP205879R1 Analog input channel ABB
BCU-02Package INU, XT ABB
BC810K01 ABB  Bus interconnect unit suite
ABB  BC810 NMD90  Zinc connector
B161S-E176 driver SECO
ABB  B5EEd-HENF105082R4 Control card module
ABB B5EC-HENF105077R1 Electric power automation
B3EA-HENF315147R1 Terminating unit ABB
AZ05-0-0-1 AMK driver
ASSY-11994R13 Circuit board module
AS-P892-000  Schneider Single cable RIO interface
AS-B875-002  800 series I/O module  Schneider
APBU-44C ABB  Branching unit kit APBU
AO2040 Central unit ABB
AO845A Analog output S/R HART 8 channel ABB
AO820 Separate electrical isolation channel ABB
AO810V2-3BSE038415R1 analog output 8 channels ABB
AO810V2 Analog output 8 channels ABB  Terminal unit
AO810-3BSE008522R1 Analog output 1×8 channel ABB
AO801 ABB Analog output 8 channels
AO610 ABB  Analog output 16Ch
AO202SI Analog output module
ANR5131 Micro laser sensor
AMM42 Control unit YOKOGAWA
AL8XGTE-3 PCI bracket on the circuit board
AIP830-101 Operating keyboard
AIP571-BUS1  YOKOGAWA  Automation controller
AIP171 Optical fiber communication system
AIP121-S00 YOKOGAWA output modules
AI830A The input module has 8 channels
AI820 ABB  Analog input module
AI810 Analog input 8 channels ABB
AI625 ABB  Analog input 16 channels
AGPS-21C ABB  POWER SUPPLY
AEM402 Incremental encoder
ACN-CS High performance and multi-function
ACC-5595-208-350-805595-208N Reflective memory hub
5SHY35L45039 Asymmetric Thyristor IGCT ABB
ABB 5SHY35L4503 Asymmetric Thyristor IGCT
AAP3798102-00037  Operation panel
A413654  METSO  Control valve
A413240 Controller Quartz Series  METSO
A77146-220-51 Control Board
A6824R-9199-00098-13 Vibration sensor EPRO
A6824 Vibration velocity sensor EPRO
A4722-9215KM Sensors and actuators
A5E36717788 ABB Controls and drives IGBT modules
A4H254-8F8T Network module  Enterasys

Reviews

There are no reviews yet.

Be the first to review “IS200DTURH1ACC Reliable Turbine Control Solutions”

Your email address will not be published. Required fields are marked *