Sale!

IS200AEPCH1CCB General Electric Processor Board Mark VI

Original price was: $1,888.00.Current price is: $1,688.00.

МодельIS200AEPCH1CCB

Первоначальная гарантия на один год.
IS200AEPCH1CCB Параметры

IS200AEPCH1CCB Размер 30 * 20 * 30
IS200AEPCH1CCB Вес 2 кг

Контактное лицо: г – н Рай

WeChat: 17750010683

WhatsApp: + 86 177500 10683

Электронная почта 3221366881@qq.com

Category:

Description

IS200AEPCH1CCB General Electric Processor Board Mark VI
IS200AEPCH1CCB General Electric Processor Board Mark VI
IS200AEPCH1CCB General Electric Processor Board Mark VI Product details:

IS200AEPCH1CCB Technical Manual

IS200AEPCH1CCB Weight:1.8KG
IS200AEPCH1CCB Size: 20* 20 * 10cm
IS200AEPCH1CCB instructions
IS200AEPCH1CCB PDF
IS200AEPCH1CCB  – это панель связи возбудителя для передачи данных между контроллерами.
666666 Описание функций
ISBus – это защищенный интерфейс связи GE, используемый для передачи данных между контроллерами M1, M2 и C возбудителя. EISB – это модуль с одним слотом и высотой 3U, расположенный в раме управления под DSPX.
IS200AEPCH1CCB  Сигналы тока и напряжения от магнитного поля генератора (включая, при необходимости, возбудитель) принимаются через волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
Применение данных
У EISB нет светодиодных индикаторов, трамплинов или предохранителей.
Соединитель
Следующие волоконно – оптические разъемы расположены на передней панели платы и используются для приема и передачи сигналов преобразования частоты IS200AEPCH1CCB :
• Ввод напряжения постоянного тока на месте для генераторов с пластиной EDCF
• Ввод тока на панели EDCF в аэропорту постоянного тока
Ввод напряжения возбудителя EDCF (необязательно)
Ввод тока в возбудитель EDCF (необязательно)
• Ввод напряжения в детектор заземления
• Переключатель сброса напряжения на выходе из приемника заземления также вогнут за отверстие в нижней части передней панели
Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683

In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.

Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.

Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.

2.2 Design and implementation of security protection functions

Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.

First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values ​​are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values ​​and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values ​​corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.

In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
​​of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.

3 Conclusion

The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.

DS200FHVAG1ADA High voltage door interface card
DS200FGPAG1AKD pulse amplifier board
DS200FECBG1A excitation card GE drive system
DS200FCSAG2ACB control current sensing interface board
DS200FCRRG2A PLC controller
DS200FCRRG1ACA circuit control card
DS200FCRRG1A Mainboard interface board
DS200FCRLG1AFC ignition circuit card
DS200FCRLG1A DI/DO control card
DS200FCGDH1B DCS control module
DS200EXPSG1ACB Turbine power supply card
DS200EXPSG1ABB PC board communication adapter
DS200EXPSG1A Turbine power supply card
DS200EXDEG1A GE excitation control board
DS200EVIAG1B control system
DS200DTBDG1A CPU module
DS200EVIAG1B Main board Interface board
DS200DTBCG1A DI/DO control card
DS200DTBAG1A system spare parts
DS200DTBBG1A controller main unit
DS200DSPDF1A input control board
DS200DSPCH1ADA DCS system module
DS200DSPAG1AAB Digital output board
DS200DMCAG1AHC Analog quantity module
DS200DMCAG1AGB DCS card module
DS200DENQF1BDE analog module
DS200DENQF1BDE Serial port measuring board
DS200DENQF1B inverter communication card
Medium voltage circuit board DS200DENCF1BDE02
DS200DENCF1BDE01 Control system module
SDCS-FEX-2A  ABB  Excitation plate
DS200DDTBG2ABB I/O terminal board
SCA640-74GM  BASLER  Industrial camera
DS200DCVAG2A Dc power supply and instrument panel
DS200DCPAG1A Output module
DS200DCFBG2B DC feedback board
DS200DCFBG1BUN Turbine control
DS200DCFBG1BNC medium voltage circuit board
DS200DCFBG1BLC Medium voltage circuit board
DS200DCFBG1BKC digital input module
DS200DACAG1A Converter board
DS200CVMAG3A monitor
DS200CVMAG1A turbine control panel
DS200CTBDG1A Programmable controller
DS200CTBAG1A processor terminal board
DS200CSSAG1B sensor board
DS200CSSAG1A printed circuit board
DS200CPCAG1A Analog output module
DS200CLACG1A CPU controller
DS200CDBAG1B Servo drive driver
PN-43652  A-B  Main control panel kit
DS200ADPAG1A DCS spare parts
DS200CDBAG1A Control system I/O module
DS200ADCIH1A Control module
DS200ACNAG1A Analog input module
DS200AAHAH2A System card piece
DS200AAHAH1A DCS module

Reviews

There are no reviews yet.

Be the first to review “IS200AEPCH1CCB General Electric Processor Board Mark VI”