Sale!

IEPU02 DCS excitation system

Original price was: $1,888.00.Current price is: $1,688.00.

Model:IEPU02

New original warranty for one year

Brand: ABB

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Product parameters
Model: IEPU02
Brand: ABB
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
IEPU02 is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
IEPU02 is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: IEPU02 Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install IEPU02 correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating IEPU02 to ensure proper use.
Product Introduction
IEPU02 is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

Practical application of ABB industrial information control system 800xA in main shaft hoist control
introduction

The mine hoist is an important transportation equipment for mining enterprises. Its main function is to transport the ore,
personnel or equipment that need to be transported to the destination by the lifting container. Therefore, it plays a very
important role in the mining production process. Usually the mine hoist control system consists of a driving part and a
control part. The working mechanism
of the driving part is: the motor unit drives the mechanical hoisting device, and the frequency converter or other types
of hoisting control systems drive the motor unit: the working mechanism of the control part is: Each component of the
hoist is coordinated and controlled by the
Distributed Control System (DCS). In addition to completing basic process control, it can also integrate intelligent instruments,
intelligent transmission and motor control, and even production management and safety systems into one operation and engineering environment
middle. Therefore, the mine hoist requires a control system with high performance, high reliability, and high integration.

1ABB800xA system and AC800M controller introduction

1.1ABB800xA system introduction

The 800xA system is an industrial information control system launched by ABB. The core of its architecture is
object-oriented (ObjectOriented) technology. Due to the adoption of ABB”s unique Aspect0object concept,
enterprise-level information access, object navigation and access can become standardized and simple.

In order to provide a unified information platform for enterprise managers and technical personnel, the 800xA system
provides a base platform (BasePlatform), which relatively separates the process control part and production control
management and organically combines them together. As shown in Figure 1, the middle part is the basic platform, the upper part is the production control
management part, and the lower part is the process control part. The basic platform provides standard interfaces for
these two parts for data exchange.
1.2 Introduction to ABBAC800M controller and its programming configuration tools

AC800M controller is ABB”s latest controller series, which includes a series of processors from PM851 to PM865.
The AC800M controller itself has a pair of redundant TCP/IP interfaces. It can use the MMs protocol to communicate
with other control devices and 800xA operator stations through Ethernet. It can also use the Modbus protocol and
Point-Point protocol through 2 serial ports. communication. The programming and configuration tool of AC800M is
ControlBuilderM,
referred to as CBM. It supports standard ladder diagram, function block language, text description
language and assembly language to write control logic.

2. Improve the design and implementation of control system functions

2.1 Implementation of elevator operating speed curve

One of the main tasks of the lifting control system is to control the lifting motor to operate according to the speed-position
curve given by the design, so that the lifting container passes through the acceleration section, the uniform speed
section and the deceleration section successively, and stops accurately after completing the specified lifting distance
. somewhere in the wellbore. In order to realize the function of precise position calculation, the designed
elevator control system must be able to perform high-precision position calculation based on the photoelectric encoder
connected to the main shaft of the elevator drum. The
calculation formula is as follows:
In the formula, s is the actual position value of the elevator: sp is the distance corresponding to two consecutive encoder
pulses: AN is the difference between the encoder count value at the reference position and the current position (signed variable):
s0 is the reference position value.

The encoder counts are distributed according to the circumference of the drum. After the number of pulses Np generated
by the encoder rotation is known, the diameter of the circumference of the centerline of the wire rope wrapped around the
drum must be accurately known, so that it can be calculated according to formula (2) The distance sp corresponding to the two encoder pulses:
In the formula, D is the circumferential diameter of the centerline of the wire rope: Np is the number of pulses for one revolution of the known encoder.

But in formula (2), there is a value D that keeps getting smaller as the system runs. This is because the wire rope
used in the elevator is wrapped around the drum, and there is a lining between the wire rope and the drum that increases
friction. This liner will become thinner and thinner as the system continues to wear and tear, causing the diameter of the
circle formed by the center line of
the steel wire rope to gradually become smaller. When the pad wears to a certain extent, it will cause a large position
calculation error. In order to solve the above problems, the two parking position switches in the shaft are used to correct the drum diameter, because the
distance between the two parking positions can be obtained through actual measurement with high accuracy. During the
actual operation, record the encoder count values ​​at the two parking positions respectively. According to formula (3),
the actual correction value of sp can be calculated:
In the formula, sd is the distance between two parking positions: Abs is the absolute value operation: N is the
encoder count value when there are two parking positions.

In this way, the initial sp value is first set according to the given design parameter value, and then the value is
corrected according to the actual operating conditions, which can effectively ensure the accuracy of position
calculation. At the same time, sp” can also be substituted into formula (2), and the D value can be obtained in turn,
which can be used as a basis for judging whether the liner is seriously worn.

After obtaining the elevator position value, the speed control curve can be calculated according to formula (4):

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

UFC911B106 3BHE037864R0106 System board card
UFC911B108 ABB Control module card key
UFC911B110 ABB Input control panel
UFC921A101 3BHE024855R0101 Interface module
UFD203A101 3BHE019361R0101 ABB Industrial Ethernet
UNITROL 1010 PLC control system
UNITROL 1020 ABB Input output module
UNITROL1000 Z.V3 3BHE014557R0003 ABB Numerical control module
UNS0007A-P V1 ABB DCS controller module
UNS0119A-P,V101 ABB Digital input submodule
UNS0874A ABB  Control I/O module
UNS0887A-P 3BHE008128R0001 Analog input module
UNS2880b-P,V2 3BHE014967R0002 Analog output circuit board
UNS2881B-P V1 ABB Robot network communication card
UNS2882A 3BHE003855R0001 Connecting terminal unit
UNS2980c-ZV4 ABB Robot axis calculation board
UNS4881b,V4 3BHE009949R0004 ABB Analog output circuit board
UNS3670A-Z V2 HIEE205011R0002 Servo servo module
C3K122-24P ENTERASYS Controller module
C3K122-24 ENTERASYS Control of signal
C3G124-48 ENTERASYS  Processor module
C3G124-24 ENTERASYS  Processor module
ENTERASYS C3G124-24P Network interface module
08G20G4-48P  800-Series Layer 2 switch
08G20G4-48  800-Series Layer 2 switch
08G20G4-24P  800-Series Layer 2 switch
08G20G2-08P  800-Series Layer 2 switch
ENTERASYS 08H20G4-48 800-Series Layer 2 switch
08G20G2-08  800-Series Layer 2 switch ENTERASYS
08H20G4-48P 800-Series 10/100 Switches ENTERASYS
08H20G4-24P ENTERASYS switch
08H20G4-24 ENTERASYS 24 port 10/100 800-Series Layer 2 switch
B5K125-48 and B5K125-48P2 ENTERASYS gateway
B5K125-24 and B5K125-24P2 ENTERASYS  Switch
B5G124-24 and B5G124-24P2 Ethernet Switch
ENTERASYS B5G124-24 Ethernet Switch
I3H252-8TX-2FX ENTERASYS High-end Secure Networks
I3H252-8FXM ENTERASYS
I3H252-6TX-MEM ENTERASYS Ethernet
ENTERASYS I3H252-4FX-MEM Ethernet L2 Switch
switch I3H252-4FXM ENTERASYS
I3H252-12TX ENTERASYS Ethernet switch
Switch A2H254-16 ENTERASYS
A2H124-24FX Switch ENTERASYS
ENTERASYS A2H124-48P Switch Ports
A2H124-48 Switch Ports ENTERASYS

Reviews

There are no reviews yet.

Be the first to review “IEPU02 DCS excitation system”

Your email address will not be published. Required fields are marked *