Description
IC697CHS750 General Electric
высотой 3U, расположенный в раме управления под DSPX.
волоконно – оптический разъем на передней панели и передаются в модуль обнаружения заземления.
ABB: Запасные части для промышленных роботов серии DSQC, Bailey INFI 90, IGCT, например: 5SHY6545L0001 AC1027001R0101 5SXE10 – 0181, 5SHY3545 L0009, 5SHI3545L0010 3BHB013088 R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512, PPPD113, PP836A, P865A, 877, PPP881, PPPP885, PPSL500000 4 3BHL00390P0104 5SGY35L4510 и т.д.
General Electric: запасные части, такие как модули, карты и приводы. Например: VMVME – 7807, VMVME – 7750, WES532 – 111, UR6UH, SR469 – P5 – HI – A20, IS230SRTDH2A, IS220PPDAH1B, IS215UCVEH2A, IC698CPE010, IS200SRTDH2ACB и т.д.
Система Bently Nevada: 350 / 3300 / 1900, предохранительные зонды и т.д., например: 3500 / 22M, 3500 / 32, 3500 / 15, 3500 / 23500 / 42M, 1900 / 27 и т.д.
Системы Invis Foxboro: Серия I / A, управление последовательностью FBM, трапециевидное логическое управление, обработка отзыва событий, DAC,
обработка входных / выходных сигналов, передача и обработка данных, такие как FCP270 и FCP280, P0904HA, E69F – TI2 – S, FBM230 / P0926GU, FEM100 / P0973CA и т.д.
Invis Triconex: Модуль питания, модуль CPU, модуль связи, модуль ввода – вывода, например 300830937214351B, 3805E, 831235114355X и т.д.
Вудворд: контроллер местоположения SPC, цифровой контроллер PEAK150, например 8521 – 0312 UG – 10D, 9907 – 149, 9907 – 162, 9907 – 164, 9907 – 167, TG – 13 (8516 – 038), 8440 – 1713 / D, 9907 – 018 2301A, 5466 – 258, 8200 – 226 и т.д.
Hima: модули безопасности, такие как F8650E, F8652X, F8627X, F8678X, F3236, F6217, F6214, Z7138, F8651X, F8650X и т.д.
Honeywell: Все платы DCS, модули, процессоры, такие как: CC – MCAR01, CC – PAIH01, CC – PAIH02, CC – PAIH51, CC – PAIX02, CC – PAON01, CC – PCF901, TC – CR014, TC – PD011, CC – PCNT02 и т.д.
Motorola: серии MVME162, MVME167, MVME172, MVME177, такие как MVME5100, MVME5500 – 0163, VME172PA – 652SE, VME162PA – 344SE – 2G и другие.
Xycom: I / O, платы VME и процессоры, такие как XVME – 530, XVME – 674, XVME – 957, XVME – 976 и т.д.
Коул Морган: Сервоприводы и двигатели, такие как S72402 – NANA, S6201 – 550, S20330 – SRS, CB06551 / PRD – B040SSIB – 63 и т. Д.
Bosch / Luxer / Indramat: модуль ввода / вывода, контроллер PLC, приводной модуль, MSK060C – 0600 – NN – S1 – UP1 – NNN, VT2000 – 52 / R900033828, MHD041B – 144 – PG1 – UN и т.д.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
EATON C825KN10 200A 600V Contactor Ser A2 120V
1762-IF4 Analog input module
FC-PSU-240516 Power Supply Module
3500/42M 140734-02 Proximitor Seismic Monitor
FOXBORO P0973JX Industrial switch
1440-DYN02-01RJ Dynamic measurement module
GESAS CAN-DPV 1168411 AMPLIFIER MODULE
FBM201D Analog Input Interface Modules
MSK030C-0900-NN-M1-UG1-NNNN R911308684 motor
1746-NI4 four-channel analog input module
Allen-Bradley 1746-NO4I Analog output module
1747-L552 B/C CPU MODULE
3500/92 136188-02 Communication Gateway
05704-A-0146 5704F Fire Control Card
Yaskawa JGSM-06 Position Controller
LAM 853-049542-173 Circuit board
SICK MZT8-03VPS-KUD 1054051 T-slot cylinder sensor
8MSA4S.R0-31 B&R servomotor
Allen-Bradley 1771-P5 power supply
ABB IMFCS01 Frequency counter module
YASKAWA CACR-SR07BE12M SERVO PAK DRIVE
41B5228X232 I/O Module CL6921X1-A6
41B5228X192 Analog Interface I/O Module CL6921X1-A6
41B5228X082 Analog Interface I/O Module CL6921X1-A6
41B5228X072 CL6921X1-A6 Analog Interface I/O Module
41B5222X44R Analog I/O Module CL6821X1-A5
41B5222X422 CL6821X1-A5 Analog I/O Module
41B5222X36R CL6821X1-A4 Analog I/O Module
41B5222X35R CL6821X1-A4 Analog I/O Module
41B5222X33R CL6821-A5 Analog I/O Module
41B5222X242 CL6821X1-A5 Analog I/O Module
41B5222X232 CL6821X1-A4 Analog I/O Module
41B5222X222 CL6821X1-A4 Analog I/O Module
41B5222X072 CL6821X1-A3 Analog I/O Card
41B5222X092 CL6821X1-A2 Analog I/O Module
41B5222X072 CL6821X1-A1 Analog I/O Card
41B5222X032 CL6821X1-A1 Analog I/O Card
41B5222X032 CL6821X1-A1 Analog I/O Card
41B5215X122 CL6721X1-A3 Discrete I/O Module
41B5215X132 Digital I/O Module
KJ3243X1-BB1 Series 2 Plus Profibus DP Modle
KJ3222X1-BA1 Analog Input HART Module
KJ3221X1-BA1 Analog Output HART Module
KJ3221X1-BA1 Analog Output HART Module
KJ3242X1-BA1 Fieldbus H1 Series 2 Card
KJ3241X1-BA1 Redundant Serial Interface Card
KJ3242X1-BA1 Fieldbus Module
KJ1501X1-BC2 Power Supply
KJ1501X1-BC1 Power Supply
KJ3006X1-BA1 Power Supply
KJ2003X1-BA2 MD Controller
KJ2003X1-BA2 MD Controller
KJ2003X1-BA1 Controller MD Module
KJ3005X1-BA1 Controller Module
KJ3005X1-BA1 AS-i Card
KJ3001X1-CA1 Dry Contact Module
KJ3001X1-CA1 Discrete Input Module
мы организуем фото на складе, чтобы подтвердить
чтобы вернуть их вам. Конечно, мы ответим на ваши озабоченности как можно скорее.
Reviews
There are no reviews yet.