Description
hardware flow control. It is an ideal choice in the field of industrial automation.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the
elevator: V2 is the maximum speed of the elevator at this position.
Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the
end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still
1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.
Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can
be relatively improved, which is particularly important when the auxiliary shaft is lifted.
2.2 Design and implementation of security protection functions
Mines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high
reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures
may occur, and detects the actions and feedback signals of these protection devices in real time.
First of all, monitoring the operating status of the elevator is the top priority in the safety protection
function of the elevator control system. In the control system, the operating speed and position of the
motor are monitored at all times, and the current position and speed values are compared with the system”s
designed speed and position curve. Once it is found that the
actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency
stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire
lifting process. At the same time, position detection switches are
arranged at several locations in the wellbore, and these position detection switches correspond to specific
position values and corresponding speed values. When the elevator passes these switches, if it is found through
encoder detection that the actual speed value and position deviate from the values corresponding to the position
detection switch, the control system will also judge that it is in a fault state
and immediately implement an emergency stop.
In order to determine whether the encoder connected to the main shaft of the elevator drum is normal,
two other encoders are installed on the elevator. In this way, the position and speed detection values
of the three encoders are always compared. Once it is found that the deviation between the detection
value of one encoder and the detection value of the other two encoders exceeds the allowable range,
the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.
3 Conclusion
The efficient and safe operation of main well equipment is an important guarantee for its function.
In the application of mine hoist, the 800xA system designed speed curve, self-correction, various
self-diagnosis and protection functions according to the specific process characteristics of the main
shaft mine hoist, which has achieved good results in practical applications.
DEIF MALLING KONTROL 910.51 CONTROL PANEL
DANFOSS ADAP-KOOL TYPE-AKC25A COMPRESSOR PACK CONTROLLER
CUMMINS 3413905 ELECTRONIC GOVERNOR CONTROLLER
CUMMINS 3098693 REV-K GOVERNOR ELECTRONIC CONTROLLER
CONSILIUM MODEL 101 PROCESS CONTROL EQUIPMENT
CONFOR STALECTRONIC 2000 1891-726 PCB CARD
CHROMALOX LIMIT 10100 TEMPERATURE CONTROLLER
CHROMALOX 2104 TEMPERATURE CONTROLLER
BEMAC UGS-21 AUTO GENERATOR CONTROLLER
BOSCH 0 811 405 073 VALVE AMPLIFIER CARD
BASLER AVC63-7F ANALOG VOLTAGE CONTROLLER
BARBER COLMAN DYNA-10502-002-0-24 GOVERNOR CONTROLLER
AZBIL SDC26 DIGITAL TEMPERATURE CONTROLLER
AUTRONICA BU-70 FIRE ALARM CONTROL PANEL
ARTISAN 4950H 7DAY BELL CONTROLLER
AQUAMASTER-RAUMA STC-2X-944424 SECONDARY TURNING CONTROLLER
AQUAMASTER-RAUMA STC-2-AQ7351413 SECONDARY TURNING CONTROLLER
AQUAMASTER-RAUMA ROLLS-ROYCE PFC-3X-TJ52634 PROPULSIVE FORCE CONTROLLER
AQUAMASTER-RAUMA ROLLS-ROYCE AQATC-3-TK52672.1 AQUAMASTER TURNING CONTROLLER
AQUAMASTER-RAUMA KAMEWA KAMEWA PBC-01-ACD-7353679-001 PITCH BACKUP CONTROLLER
AQUAMASTER-RAUMA ATC-2-A7030004 AQUAMASTER TURNING CONTROLLER
AQUAMASTER RAUMA TYPE-STC2X-944424 SECONDARY TURNING CONTROLLER
AQUAMASTER RAUMA TYPE-STC2-AQ7351413 SECONDARY TURNING CONTROLLER
AQUAMASTER RAUMA TYPE-STC1-ACD7351413-1 SECONDARY TURNING CONTROLLER
AQUAMASTER RAUMA STC2-AQ7351413 SECONDARY TURNING CONTROLLER
AQUAMASTER RAUMA AIU3-7030008-1V69 CONTROLLER MODULE
ABB-AUTRONICA VD86 SCAN VIDEO CONTROLLER
ABB COMMANDER 300 UNIVERSAL PROCESS CONTROLLER
ZOLLER ELEKTROTECHNIK AHD 419 THRUSTER PROPELLER CONTROL PANEL
ZENTRALE SMA-48.0-901001 CONTROL PANEL
YORK REFRIGERATION UGS-11-USY11 OPERATOR PANEL
YOKOGAWA DENSHIKIKI ASSY V8219 SERVO CONTROL BOARD
WOODWARD PN-8400-015-D-PROACT-MA DIGITAL SPEED CONTROL PANEL
WOODWARD 9905-797 DIGITAL SYNCHRONIZER AND LOAD CONTROL PANEL
WOODWARD 8272-683 CONTROL DIGITAL REFERENCE UNIT
WOODWARD 723-PLUS DIGITAL CONTROL PANEL
WOODWARD 723-9906-619-8280-604 REV-F-D DIGITAL CONTROL
WOODWARD 723-9906-619-8280-412 REV-B-E DIGITAL CONTROL
WOODWARD 723-9906-619-8280-1009 REV-C-A DIGITAL CONTROL
WOODWARD 723-9906-619 REV-C-J DIGITAL CONTROL
WOODWARD 723 DIGITAL CONTROL
WARTSILA MCM-11 PN-46WMCM03_I HW-REV.04 MAIN CONTROL MODULE
WARTSILA MCM-11 PN-46WMCM_I HW-REV.03 MAIN CONTROL MODULE
VOLVO PENTA PN-3884604-ID-MCU MARINE CONTROL UNIT
Reviews