Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.3 Design of computer control software
This type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation,
data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.
The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information.
That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans,
save and modify plans, open existing plans, and delete plans.
The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of
each channel in real time.
3.4 Design of touch screen software
The touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions,
it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface
are shown in Figure 4 and Figure 5 respectively.
3.5 Design of PLC software
As the core of this control system, PLC is mainly responsible for the following aspects:
Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status
of the transmission system through the ProfibusDP bus protocol.
Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave
computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.
It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions
, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is
performed by accessing the PLC variable name.
Process the emergency signal and control the inverter to slow down and unload according to the default parameters.
Figure 4 Login interface
Figure 5 Test interface
3.6 Frequency converter settings
In general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter,
you must first perform the basic settings of the inverter, as follows:
Switch the control mode to local control and set the inverter address according to the inverter user manual.
Set the inverter for remote control and select the communication mode.
Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.
Set the speed control mode of the inverter, such as speed control or torque control.
After completing the basic parameter settings, switch to the remote control state and wait for remote control.
4 Conclusion
This system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to
control the inverter to control the motor
rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen,
even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen
control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is,
the motor is controlled directly through the
control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to
meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
DS200ADGIH1AAA GE Robot pipe package
DS200ACNAG1ADD GE Main interface circuit board
DS200CTBAG1A Control card piece
DS200CPCAG1A GE Frame interface module
DS200ADPBG1A Measuring photoelectric sensor
DS200ACNAG1A GE Communication card
DS200TCTGG1AFF GE Serial communication mode
PPD113B01-10-150000 3BHE023784R1023 Main interface board of the converter
3BHE024855R0101 UFC921A101 Loop communication interface module
81EU01E-E Positioning module
560CMU05 Digital modulation board
DSQC346U Switch power supply
GRBTU 3BSE013175R1 I/O terminal board
HIEE300024R4 UAA326A04 Communication board
KUC711AE101 3BHB004661R0101 Power supply module
KUC720AE01 3BHB003431R0001 8 channel digital input
KUC755AE105 3BHB005243R0105 Robot IO module
KUC755AE106 3BHB005243R0106 Inverter control panel
PU515A 3BSE032401R1 Communication module
RDCU-02C ABB High speed counting module
RDCU-12C Servo control unit
UAA326A02 Servo control system
UAC318AE Digital signal output module
UAC326AE The I/O board
UAD142A01 3BHE012551R0001 Bus adapter
UAD154A Robot board card
UAD155A0111 3BHE029110R0111 Thyristor module
UBC717BE101 3BHE021887R0101 Programmable controller module
UCD208A101 Current transformer
UCD224A102 Converter main control board
UCD224A103 Robot base plate
UCD240A101 ABB Axial computer board
UDD406A ABB Power module
UFC092BE01 Axial computer board
UFC718AE101 HIEE300936R0101 ABB Driving power supply
DS3800NFIB Mark IV Board
DS3800NFLA Mark IV Board
DS3800NFLA1C1C Mark IV Board
Reviews
There are no reviews yet.