Sale!

FSC10014/F/F Redundant power supply for C300

Original price was: $1,888.00.Current price is: $1,688.00.

Model:FSC10014/F/F

New original warranty for one year

Brand: Honeywell

Contact person: Mr. Lai

WeChat:17750010683

WhatsApp:+86 17750010683

Email: 3221366881@qq.com

Category:
Phone: +86 17750010683
Email: 3221366881@qq.com
connect:Mr. Lai

Description

Product parameters
Model: FSC10014/F/F
Brand: Honeywell
Size: 10cm x 10cm x 30cm
Weight: 1.2KG
Color: White Black
Working voltage: 5V
Working temperature: -10 ℃ to 50 ℃
Communication interface: RS232, RS485, CAN
Product specifications
Support for MODBUS protocol
Support hardware flow control
Using high-speed CMOS devices
Support for data caching
application area
FSC10014/F/F is mainly used in the field of industrial automation, such as DCS PLCs, industrial controllers, robots, etc.
FSC10014/F/F is mainly used in steel manufacturing, thermal power generation, hydroelectric power generation, glass manufacturing, paper mills, cement factories, petrochemicals
Chemical fiber, pharmaceutical manufacturing, rubber, plastics, ferrous metal food, machine tools, specialized equipment, transportation vehicles, mechanical equipment
Electronic communication equipment, instruments and beverages, tobacco processing, clothing, textiles, leather, wood processing, furniture, printing, etc
Model: FSC10014/F/F Brand: ABB Archive Function: Communication Function Product Certification: Qualified
Working voltage: 24V Internal variable: No pattern Type: Vector diagram Applicable range: Industrial type
Number of screens: 4 Imported or not: Yes Customized for processing: No
Alarm function: Product name: Module Input voltage: 24V Rated current: 5A
Special service: including postage. Remarks: one-year warranty. Operation method: remote control
Applicable motor: servo motor system memory: 8MB Display color: 99.9 color gamut
Power voltage: 220V Input method: Current Input Material code: 65218
Communication interface: HDMI interface Working temperature: 60 Material number 26854 Other functions Analog communication
Output frequency: 50HZ Rated voltage: 24V Alarm type: Light alarm
Disconnect capacity: 0.01 Vector graph support: Minimum number of packages supported: 1
Display type: IPS USB interface quantity: 2 interfaces Memory card slot: 2
Panel protection level: 3 Memory expansion capacity: 128MB User script support: supported
Speed response frequency: 1MS Working environment temperature: -40 to 100 Insulation withstand voltage test: Passed
Third party communication products: ABB controllers available for sale in: nationwide
Product Instructions
Please install FSC10014/F/F correctly on the device and connect the communication interface cable properly.
Please refer to the user manual for operating FSC10014/F/F to ensure proper use.
Product Introduction
FSC10014/F/F is a high-performance industrial automation communication module that uses high-speed CMOS devices, supports MODBUS protocol, and supports
hardware flow control. It is an ideal choice in the field of industrial automation.

(1) Use STEP7V5.2 configuration software and enter Hardware Configure to complete S7-300 PLC hardware configuration;

(2) Select S7-315-2DP as the main station system, import the GSD (device database) file of NPBA-12 into the STEP7 programming environment, and configure the software
to configure NPBA-12 with S7-315-2DP as the main station. DP online, and select the PPO type to use. This design uses PPO4 to set the site network address. In the Profibus
structure of the variable frequency drive device, ABB frequency converters use the Profibus-DP communication module (NPBA-12) for data transmission, which is
mainly periodic: the host reads the input information from the slave station and sends the output information back to the slave station. ,
so it is necessary to call two system function blocks SFC14 and SFC15 in the PLC main program to read and write these data to achieve communication control to
the frequency converter;

(3) Create a data block in the main PLC program for data communication with the frequency converter; establish a variable table for observing the real-time
communication effect.

4 Inverter operation settings

After the frequency converter and PLC are connected to a network using Profibus-DP fieldbus, in addition to programming in the PLC automation system,
appropriate parameter settings must also be performed on each frequency converter.

After the communication cable is connected, start the inverter and complete the setting of the inverter communication parameters.

4.1 Basic settings

(1) 51.01—Module type, this parameter displays the module model detected by the transmission device. Its parameter value cannot be adjusted by the
user. If this parameter is not defined, communication between the module and the drive cannot be established.

(2) 51.02—This parameter selects the communication protocol, “0” selects the Profibus-DP communication protocol.

(3) 51.03—This parameter is Profibu

The PPO type selected by s connection, “3” is PPO4, but the PPO type on the inverter should be consistent with the PPO type configured on the PLC.

(4) 51.04—This parameter is used to define the device address number, that is, the site address of the frequency converter. Each device on the Profibus
connection must have a separate address. In this design, the two frequency converters are stations 2 and 3 respectively. [1]

4.2 Connection of process parameters

The process parameter interconnection completes the definition and connection of the corresponding parameters of the NPBA-12 dual-port RAM
connector and the frequency converter, including the connection from the master station (PLC) to the frequency converter and the connection from the frequency
converter to the master station (PLC). Set the following connection parameters on the frequency converter.

(1) PZD value sent from PLC to transmission inverter

PZD1—control word, such as start enable, stop, emergency stop and other control commands of the frequency converter;

PZD2—frequency setting value of the inverter.

(2) PZD value sent from the transmission inverter to the PLC

PZD1—status word, such as alarm, fault and other inverter operating status;

PZD2—actual speed value, current actual value, etc. of the frequency converter.

5 Conclusion

After the inverter control system adopts the Profibus-DP fieldbus control mode, the entire system not only has strong reliability and is easy to operate, but also can
be flexibly modified according to process needs. After this system was applied in Jigang Baode Color Plate Co., Ltd., it has been running well and has provided a successful
example for the future automation equipment (network communication of different manufacturers) of the head office.

New technology from Swiss ABB Group: Complete car charging in 15 seconds

This technology can charge a car in 15 seconds

The Swiss ABB Group has developed a new electric bus technology that can complete vehicle charging in 15 seconds . No other company”s battery technology can achieve this performance.

ABB has developed a technology called “Flash Charging” that allows an electric bus with 135 passengers to charge at charging points along the route. The charging point has a
charging power of 400 kilowatts and is located above the vehicle. The charging point is connected to a moving arm controlled by a laser and can charge the car battery in 15 seconds. Its
minimal design will help protect the urban environment and surrounding landscape.

The idea behind this design is to give the electric bus enough power to travel to the next charging station after one charge. The end of the line will allow for long periods of full charging
, with the car able to travel longer distances on a full charge. In addition to faster charging times, the system uses a carbon-emission-free solution called
TOSA to obtain electricity from clean hydroelectric power stations.

ABB initially plans to use this technology between Geneva Airport and the Palexpo International Convention and Exhibition Center. If the test is successful
, it will be deployed to public transportation systems. This is more cost effective and environmentally friendly.

ABB Executive Chief Technology Officer Claes Rytoft said: “With flash charging, we can trial a new generation of electric buses for large-scale transportation
in cities. This project will provide greater flexibility, cost-effectiveness and flexibility.” Paving the way for a lower public transport system while reducing pollution and noise.”

Contact person: Mr. Lai
Mobil:17750010683
WeChat:17750010683
WhatsApp:+86 17750010683
Email: 3221366881@qq.com

https://www.xmamazon.com

https://www.xmamazon.com

Home

Home

https://www.plcdcs.com/

www.module-plc.com/

https://www.ymgk.com

8800-1001 WOODWARD digital speed switch
REF611 HCBACB2AA1XE feeder protection and measurement and control device
MPL-B430P-HJ74AA servo motor
1756-PB72 A-B ControlLogix Power Supply
1734-AENTR I/O Dual Ethernet communication module
1769-L24ER-QB1B CompactLogix Encapsulates the controller
TZIDC-V18345-1010521001 Electropneumatic positioner
A5E31250567 ABB rectifier power module
AAI143-S50 YOKOGAWA analog input module
3500/50M-01-00 tachometer module
DCF803-0050 Excitation board Power board
350033-SIL2-01-CN 16-channel relay module
350025-SIL2-01-01-CN Enhanced Keyphasor module
V18311H-112110100 signal converter
M700-04400150A 7.5KW 3PH driver
DST1404P servo drive
SP2403 400 volt AC panel mounting driver
6ES7331-7NF10-0AB0 Indicates the analog input module
2094-BM02-S Integrated shaft module A-B
MAX-4/11/03/128/99/1/1/00 servo drive ELAU
FPBA-01 PROFIBUS DP adapter module
TREXLHPKLWS3S Trex device communicator
1444-DYN04-01RA Intelligent I/O module
ZCU-12 ABB demonstration unit
9200-06-05-10-00 Speed sensor
F3CU04-0S Yokogawa temperature control and PID module
NFAI143-H50 Yokogawa analog input module
NFBU200-S05 Yokogawa Analog input module
SAI143-S53 Yokogawa analog input module
IC694PWR331 GE power module
1326AB-B730E-M2L AC servo motor A-B
SPASI23 ABB analog input module
SGDH-15DE Yaskawa servo amplifier
PM564-TP-ETH ABB logical controller
1756-PB75 ControlLogix Power module
IC694ACC310 empty slot filling module DCS analog
IC695ALG708 Analog output module
IC695CPE305 RX3i PACSystems CPU
IC695ALG616 Indicates the analog input module
IC695PBM300 Main PROFIBUS module
IC695ACC400 RX3i Series Power Pack
IC695PSD140 Power module GE
IC695CBL001 GE cable
IC694TBB132 GE expansion box terminal panel
IC695LRE001 GE Serial bus transmitter module
IC755CSS12CDB GE 12.36-inch QuickPanel operation screen
CIMR-AB4A0038FBA YASKAWA Inverter
CC-TAID11 HONEYWELL differential analog input IOTA
5069-L380ERM CompactLogix controller
TB840A 3BSE037760R1 Modulebus
SA811F SA801F AC800F Power module ABB
531X307LTBAJG1 LAN terminal board 531X series
TY720 YOKOGAWA Digital Multimeter
CA500 YOKOGAWA high performance multifunctional calibrator
WT310 YOKOGAWA Digital Power meter
VT-VSPD-1-2X/V0/0-0-1 digital amplifier REXROTH

Reviews

There are no reviews yet.

Be the first to review “FSC10014/F/F Redundant power supply for C300”

Your email address will not be published. Required fields are marked *