Description
hardware flow control. It is an ideal choice in the field of industrial automation.
3.2 Upgrading of regulators and control systems
For the upgrade of the regulator, the original excitation control system cabinet structure is retained, and the entire system is upgraded by upgrading the board card.
Among them, the CoB main board, MUB measurement board, F10 input and output board, and LCP local control panel were replaced with the PEC800 controller,
CCM measurement control interface board, CIo comprehensive input and output board, and ECT excitation system control terminal in the Unitrol6800 system respectively.
For the upgrade of the power cabinet, since the power of the excitation system will not change during the transformation, the N-1 redundant configuration of the five
UNL3300 rectifier bridges in the original system has not been changed, but the control and measurement parts of the rectifier
bridge have been upgraded. And the fan circuit and power control part of the rectifier bridge have been upgraded. Among them, the signal interface board (PsI) was
changed to the rectifier bridge signal interface board (CsI), the circuit breaker of the rectifier bridge panel was changed from CDP to CCP, and the rectifier bridge control
interface board (CIN) was changed to the rectifier bridge control board (CCI).
For the upgrade of the demagnetization cabinet, the switch control part was mainly upgraded. By adding a CIo board to the switch cabinet and installing a special
power distributor and relay to control the demagnetization switch, the original PsI board was removed. Secondly, in the transformation of the current detection part,
the Hall element in the Unitrol5000 system was replaced by the current relay of the Unitrol6800 system.
For the upgrade of the excitation current measurement part, the rectifier side Hall element of the rectifier bridge was replaced with an AC side CT. Relying on the linearity of the
CT, the current sharing coefficient of the excitation system was increased to 0.98, so that the role of the rectifier bridge can be fully exerted in the system. .
For the upgrade of the fan power supply circuit of the rectifier cabinet, each power cabinet can independently control the power supply of the fans in the
cabinet to avoid the problem that if the power circuit relay fails in the original system, all the fans will not work.
3.3Unitrol6800 functional logic configuration points
The Unitrol6800 system adds PT slow-blow judgment logic, and defines the actions of PT slow-blow as alarm and channel switching. The system PT
slow-blow logic pressure difference is 2% to ensure sufficient sensitivity. Since some external reasons will cause the sequential increase or decrease of magnetic
commands, a special increase or decrease magnetic contact adhesion judgment logic has been added to effectively lock out external causes. At the same
time, it can
avoid the jitter of the relay on the increase or decrease magnetic circuit and ensure the stability of the circuit. The excitation temperature detection is used to
alarm in the system, but it cannot control the system tripping. The tripping intermediate relays K291 and K292 use high-power (≥5w) relays to avoid
the problem of tripping of the excitation system
due to signal interference.
4 Problems discovered during the transformation and their solutions
After upgrading the excitation system from Unitrol5000 to Unitrol6800, since the partition between the regulator cabinets of the original excitation switch
cabinet was removed and the mounting backplate of the regulator was moved forward, the hot air from the excitation switch cabinet will enter the excitation regulator
cabinet, causing the cabinet to be damaged. The internal temperature rises, and sometimes the temperature can even reach 45°C. In order to avoid problems caused
by high temperatures, partitions were added to reduce the temperature inside the switch cabinet and control the
temperature to 30°C.
During the maintenance process, if the grounding carbon brush of the generator is removed, it is easy to cause the rotor grounding relay isoLR275 to
malfunction. Therefore, during maintenance, the power supply of the grounding relay will be disconnected and the large shaft in the magnetic cabinet will be short-circuited.
5 Conclusion
Through the transformation of the excitation system, our company not only meets the needs of increasing the generator capacity, but also
eliminates the safety hazards of ARCnet failure or flat cable damage in the excitation system of the unit. It can find the fault point during maintenance
and prevent the unit from non-stop. event. The new board used in the new excitation system has modular characteristics, which can make online maintenance more
convenient, and because the boards use trigger pulse generation communication and optical fiber redundant communication, the stability of
information transmission is ensured. Avoid communication failures and damage to pulse lines.
https://www.xmamazon.com
https://www.xmamazon.com
https://www.plcdcs.com/
www.module-plc.com/
https://www.ymgk.com
XVC517AE02 ABB PLC control panel
ZT372a-E GJR2237800R1 HE663909-31828 ABB procontrol-module
369-HI-R-M-0-0-0-0 GE Motor Management Digital Relay
531X305NTBANG1 GE NTB/3TB Terminal Board 531X Series
573-935-202C VIBRO PLC module
567LH-DP24 REOTRON Drive
3708EN TRICONEX Outpout Module
9907-1183 Woodward Digital governor
125760-01 Bently Nevada Data Manager I/O Module
135613-02 Bently Nevada High Temperature Case Expansion Transducer Assembly
CB06561 PRD-B040SSlz-62 KOLLMORGEN Servo driver
CI541V1 3BSE014666R1 ABB rofibus Interface Submodule
DS200SDCIG1ABA GE RST Analog I/O Board
DS200TCQCG1BKG GE RST Overflow Board
DS215TCQAG1BZZ01A GE RST Analog I/O Board
DSMB-01C ABB power panel
DT602 GJR2911200R1 ABB DCS module
DT680E GJR2923100R1 ABB PLC module
EMDR RAYCHEM Control Unit
FSA80 Danaher Servo driver
FTA-544 17-550544-001B HONEYWELL Output Module
HE700GEN200C GE Control interface module
FTA-554 17-550554-001 HONEYWELL Output Module
HE700GEN100C GE Control interface module
HVC-02B 3HNA024966-00103 ABB Robot accessories
IC698CPE040-FJ GE Central Processing Unit
IS200JPDDG1AAA GE printed board
IS200VCMIH2BEE GE printed circuit board
IS200VTCCH1CBB GE Mark VI printed circuit board
IS220PSVOH1B GE I/O Pack, Servo Control Pack
IS230TDBTH6A GE Mark VI printed circuit board
LT9673a HESG446076R1 ABB PCB digital output unit
MC-PDIY22 HONEYWELL Digital Input 24 Vdc Processor
MS-NAE5510-3 Johnson Controller module
PFTL101A0.5KN ABB tension pick up
PM01 PM01-A-V001 SIS Bit-chip microprocessor
PM866AK01 ABB Processor unit
RLM01 ABB Redundant link module
SD802F ABB AC 800F controller
SD-108542 SD-108542-M2 GE integrated circuit board
T8110C ICS TRIPLEX Trusted TMR Processor
T8160 ICS TRIPLEX Trusted TMR Regent Interfac
UFC762AE101 3BHE006412R0101 ABB PLC Controller Module
VMIVME3122 GE VMEbus analog input/output
140CPU65160 Schneider Modicon Unity Processor
Z7306 HIMA Shunt adapter
140CPU67260 Schneider Unity hot standby processor
9907-167 WOODWARD Digital Governor
DSDP150 57160001-GF ABB Pulse encoder input unit
IS200STAOH2AAA GE Analog Output
MRP768176 IS200TDBTH6ABC GE Printed circuit board assembly
SLS1508 KJ2201X1-BA1 12P3162X112 Controller module
ICS TRIPLEX T9110 Processor Module
UFC760BE1142 3BHE0Q4573R1142 ABB control panel
Reviews